Manufacturer
INVENTUM
Model
IKG6024WGZWA
Type of hob
Gas
Number of cooking zones
4
Heating technology-1
Gas
Format-1
Help
Energy-efficiency-1
%
N.v.t.
Heating technology-2
Gas
Format-2
Normal
Energy-efficiency-2
%
62,3
Heating technology-3
Gas
Format-3
Normal
Energy-efficiency-3
%
61,3
Heating technology-4
Gas
Format-4
Rapid
Energy-efficiency-4
%
57,0
Heating technology-5
-
Format-5
-
Energy-efficiency-5
%
-
Energy-efficiency of the hob
%
60,2
This hob complies to EN 30-2-1
Checking the operation
Ignite the burners. Check whether the flame profile is uniform and stable for the complete flexibility range.
Important for this is that:
1. the flame does not smother in the simmer setting
2. the burner does not ‘blow off’ at the maximum burn setting (to be recognized to flames that are at a distance from the
burner in combination with a ‘hissing’ sound)
3. there a no tall yellow flames
The appliance was configured for the appliance category K (I2K) and is suitable for the use of G and G+ distribution gases
according to the specifications as included in the NTA 8837:2012 Annex D with a Wobbe index of 43.46 – 45.3 MJ/m3 (dry, 0
°C, upper value) or 41.23 – 42.98 (dry, 15 °C, upper value).
This appliance can moreover be converted and/or be calibrated for the appliance category E (I2E).
This therefore implies that the appliance: “is suitable for G+ gas and H gas or is demonstrably suitable for G+ gas and can
demonstrably be made suitable for H gas” within the meaning of the “Dutch Decree of 10 May 2016 regarding amendment of
the Dutch Gas Appliances Decree….”
G25.3/25 mbar*
G20/20 mbar
G30/30 mbar
kW
1
0.78 mm
0.78 mm
0.50 mm
1 Simmer burner 1.0 kW
2
1.00 mm
1.00 mm
0.66 mm
2 Semi-rapid burner 1.75 kW
3
1.36 mm
1.41 mm
0.97 mm
1 Wok burner 3.6 kW
* On pages 24 and 25 you can find more information about adjusting the appliance for different types of gas.
Gas table
English
•
25