Type number
AC125W
Voltage
220-240Volt ~50Hz
Connected load
1350 Watt
Cooling capacity*
12000Btu/h (3.2 kW)
EE Class*
A
EER*
2.6
Power consumption kW
1.2
Power consumption Standby W
0.5
Current consumption nom. A
5.3
Air displacement max. m
3
/h
300
Dehumidification max. ** L/24h
36
Suitable for m
3
105
Refrigerant / GWP type/gr
R-290 / 3 /235 g.
Thermostat range °C
18 - 32
Fan speeds
3
Max. noise level dB(A)
65 dB
Dimensions (hxwxd)
715 x 445 x 370 mm
Nett weight
31 kg
Protection class
IPX0
Remote control
yes
technical specifications
9
The appliance has an unpleasant
smell during use
• The air filter is dirty/blocked
• Clean the air filter as prescribed
The appliance does not switch on for
a period of 3 minutes after it has been
switched on.
• The internal safety system of the
compressor prevents the appliance
from being switched on until
3 minutes have passed since
it was switched off.
• This delay is normal and the
appliance will function normally
after the 3 minutes have passed
Display code
• Low temperature - freeze protection
• The appliance is provided with
a freeze protection to prevent
the formation of excess ice.
The appliance automatically restarts
once the thawing process has been
completed.
• Probe error - sensor defective
• If this code is shown on the display,
please contact customer service.
• Full water reservoir
• Empty the internal water reservoir.
In accordance with instructions
in section 6 -
discharging
condensation water