Page 8
CAUTION
CAUTION
CAUTION
This symbol shows that a service personnel should be handling this
equipment with reference to the installation manual.
This symbol shows that information is available such as the operating
manual or installation manual.
This symbol shows that this appliance uses a flammable refrigerant. If the
refrigerant is leaked and exposed to an external ignition source, there is a
risk of fire.
This symbol shows that the operation manual should be read carefully.
WARNING
CAUTION
Explanation of symbols displayed on the indoor unit or outdoor unia
(applicable to the unit adopts R32/R290 Refrigerant only):
Note about Fluorinated Gasses
1.
This air-conditioning unit contains
fl
uorinated greenhouse gasses. For specific information
on the type of gas and the amount, please refer to the relevant label on the unit itself or the
“Owner's Manual - Product Fiche ” in the packaging of the outdoor unit. (European
Union products only).
2.
Installation, service, maintenance and repair of this unit must be performed by a certi
fi
ed
technician.
3.
Product uninstallation and recycling must be performed by a certi
fi
ed technician.
4.
For equipment that contains fluorinated greenhouse gases in quantities of 5 tonnes of CO2
equivalent or more, but of less than 50 tonnes of CO2 equivalent, If the system has a leak-
detection system installed, it must be checked for leaks at least every 24 months.
5.
When the unit is checked for leaks, proper record-keeping of all checks is strongly
recommended.
Amount of refrigerant
to be charged (kg)
maximum installation
height (m)
Minimum room
area (m²)
≤
2.048
1.8m
4
≤
2.048
0.6m
35
2.048-3.0
1.8m
8
2.048-3.0
0.6m
80
>3.0
1.8m
9
>3.0
Model
(Btu/h)
≤
30000
≤
30000
30000-48000
30000-48000
>48000
>48000
0.6m
80
Cautions for using R32/R290 refrigerant
onnecting piping(when connecting indoors). Use of pipes, flareless nut or flare nuts other
than specified, may cause product malfunction, burst piping, or injury due to high internal
pressure of the refrigerant cycle caused by any inflow air.
Appliance shall be installed, operated and stored in a room with a floor area larger than
X m² (Please see the following form ). The appliance shall not be installed in an
unventilated space, if that space is smaller than X m² (Please see the following form ).
8.
Page 9
Indoor Unit Parts And Major Functions
2
Unit Parts
Air inlet
Air outlet
Fig. 2.1
Operating Conditions
Use the system under the following temperatures for safe and effective operation. If the air
conditioner is used under different conditions, it may malfunction or become less efficient.
Display panel
COOL mode
HEAT mode
DRY mode
Room Temperature
17°C - 32°C(63°F - 90°F)0°C - 30°C(32°F - 86°F) 10°C - 32°C
(50°F - 90°F)
Outdoor
Temperature
0°C - 50°C(32°F - 122°F)
-15°C - 30°C
(5°F - 86°F)
0°C - 50°C(32°F - 122°F)
0°C - 52°C(32°F - 126°F)
(For special tropical
models)
(For special tropical
models)
0°C - 52°C(32°F - 126°F)
-15°C - 50°C(5°F - 122°F)
(For models with low
temp. cooling systems.)
FOR OUTDOOR UNITS
WITH AUXILIARY
ELECTRIC HEATER
When outside
temperature is below 0°C
(32°F ), we strongly
recommend keeping the
unit plugged in at all
time to ensure smooth
ongoing performance.
•
Inverter Split Type
COOL Mode
HEAT mode
DRY mode
Indoor Temperature
17°-32°C (63°-90°F)
O°-30°C (32°-86°F) 10°-32°C (50°-90°F)
Outdoor
Temperature
18°-43°C (64°-109°F)
-7°-24°C (19°-75°F)
11°-43°C (52°-109°F)
18°-43°C (64°-109°F)
-7°-43°C (19°-109°F)
(low temperature cooling models)
18°-52°C (64°-126°F)
(For special tropical models)
18°-52°C (64°-126°F)
(For special tropical models)
•
Fixed-speed Type