1. Contact an installation specialist for installation.
2. Make sure the unit is grounded efficiently.
3. Do not use a damaged or non-standard power cord.
4. Do not share the same outlet with other appliances.
5. Do not use an extension cord.
6. Do not start/stop operation by shutting off the power supply.
1. Exposure to direct airflow for an extended period of time could be hazardous to your health.
Do not expose occupants, pets, or plants to direct airflow for extended periods of time.
2. Due to the possibility of oxygen deficiency, ventilate the room when used together with
stoves or other heating devices.
3. Do not use this air conditioner for non-specified special purposes (e.g.Preserving precision
devices, food, pets, plants, and art objects). Usage in such a manner could harm such property.
1. Do not touch the metal parts of the unit when removing the filter. Injuries can occur when handling
sharp metal edges.
2. Do not use water to clean inside the air conditioner. Exposure to water can destroy the insulation,
leading to possible electric shock.
3. When cleaning the unit, first make sure that the power and circuit breaker are turned off.
For repair and maintenance, contact your authorised service dealer.
Prior to operation
Usage
Cleaning and maintenance
service
Operating temperature
SAFETY PRECAUTIONS
5
Mode
Cooling operation
Heating operation
Drying operation
Temperature
1. If air conditioner is used outside of the above conditions, certain safety protection features may
come into operation and cause the unit to function abnormally.
2. Room relative humidity less than 80%. If the air conditioner operates in excess of this figure, the
surface of the air conditioner may attract condensation. Please set the vertical air flow louver to its
maximum angle (vertically to the floor), and set HIGH fan mode.
3. Optimum performance will be achieved within these operating temperature.
Room temperature
Outdoor temperature
o
o
o
17 C~32 C/62 F~90 F
o
o
0 C~50
C/32 F~122 F
o
o
0 C ~30 C/32 F~86 F
o
o
-15 C~ 24 C/5 F~76 F
o
o
o
o
17 C~32 C/62 F~90 F
o
o
0
C~50
C/32 F~122 F
CAUTION:
o
o
o
o
(-15 C~50 C/5
F
~122
F
:
For the models with low
temperature cooling system)
Summary of Contents for V3MFI-24
Page 17: ...1 2 3 4 5 5 6 7 10 11 12 13 13 14 8...
Page 18: ...2...
Page 19: ...3 Do...
Page 20: ...4 2...
Page 22: ...6 T2 T3 T4 T1 1 2 3 4 5 6 7 8 11 10 9 1 2 3 4 5 6 2 7 8 9 10 11...
Page 23: ...7 2 sleep turbo on off 1 2 3 5 4 1 ON OFF 17 C 30 C 17 C 30 C sleep 17 C 30 C...
Page 24: ...8 1 3 2 3 3 1 LOW AUTO 1 2 HIGH 1 3 2 2 LOW MED HIGH AUTO 1 3...
Page 27: ...11 1 3 4 10 2 3 4 5...
Page 28: ...12 6 Health 7 80 High 8 9 ON OFF 10 ON OFF 11 1 2 3 1 2...
Page 29: ...13 K 2 Anti Formol 1 2 3 4 5 6 7 1 2 3 4...
Page 47: ......