INVENTOR U4MRS-18 User Manual Download Page 4

ƒ

 Page 4 

„

Thank you for purchasing this air conditioner. This manual will provide you with information on how 

to operate, maintain, and troubleshoot your air conditioner. Following the instructions will ensure the 

proper function and extended lifespan of your unit.  

Please pay attention to the following signs:

Safety Precautions

1

Failure to observe a warning may result in death. The appliance must be 

installed in accordance with national regulations. 

.

Failure to observe a caution may result in injury or equipment damage.

 

WARNING

 

CAUTION

 WARNING

• 

Ask an authorized dealer to install this air 

conditioner. Inappropriate installation may 

cause water leakage, electric shock, or fire.  

• 

The warranty will be voided if the unit is not 

installed by professionals.  

• 

If abnormal situation arises (like burning 

smell), turn off the power supply and call 

your dealer for instructions to avoid electric 

shock, fire or injury.  

• 

DO NOT 

let the indoor unit or the remote 

control get wet. It may cause electric shock 

or fire.

• 

DO NOT 

insert fingers, rods or other objects 

into the air inlet or outlet. This may cause 

injury, since the fan may be rotating at high 

speeds.  

 

• 

DO NOT 

use a flammable spray such as hair 

spray, lacquer or paint near the unit. This 

may cause fire or combustion. 

• 

Do not use means to accelerate the 

defrosting process or to clean, other than 

those recommended by the manufacturer.

• 

The appliance shall be stored in a room 

without continuously operating ignition 

sources (for example: open flames, an 

operating gas appliance or an operating 

electric heater).

• 

The appliance shall be stored so as to 

prevent mechanical damage from occurring.

 

 

• 

Be aware that the refrigerants may not 

contain an odour.

• 

Compliance with national gas regulations 

shall be observed. 

• 

Keep ventilation openings clear of 

obstruction.

• 

DO NOT 

pierce or burn.

NOTE: 

The following informations are required 

              for the units adopt R32/R290 Refrigerant. 

• 

A warning that the appliance shall be stored 

in a well-ventilated area where the room size 

corresponds to the room area as specified 

for operation.

• 

Any person who is involved with working on 

or breaking into a refrigerant circuit should 

hold a current valid certificate from an 

industry-accredited assessment authority, 

which authorises their competence to handle 

refrigerants safely in accordance with an 

industry recognised assessment specification.

• 

• 

Servicing shall only be performed as 

recommended by the equipment 

manufacturer. Maintenance and repair 

requiring the assistance of other skilled 

personnel shall be carried out under the 

supervision of the person competent in the 

use of flammable refrigerants.

If the supply cord is damaged, it must be 

replaced by the manufacturer, its service 

agent or similarly qualified persons in order 

to avoid a hazard.

Summary of Contents for U4MRS-18

Page 1: ...E TYPE MODELS V4MCRI 18 U4MRS 18 V4MCI 24UR U4MRS 24 V4MCI 36UR U4MRS 36 V4MCI 42 U4MRT 42 V4MCI 50UR U4MRT 50 V4MCI 60UR U4MRT 60 AIR CONDITIONING SYSTEMS USER S MANUAL MANUAL UTILIZATORULUI ENGLISH...

Page 2: ...Indoor Unit Parts and Major Functions 06 Manual Operations 08 Table of Contents Owner s Manual SAFETY FIRST Safety Precautions 04 1 2 3...

Page 3: ...5 6 Cau t ion Risk of fire flammable materials WARNING Servicing shall only be performed as recommended by the equipment manufacturer Maintenance and repair requiring the assistance of other skilled p...

Page 4: ...the defrosting process or to clean other than those recommended by the manufacturer The appliance shall be stored in a room without continuously operating ignition sources for example open flames an...

Page 5: ...ly ventilate the room to avoid oxygen de ciency DO NOT climb onto or place objects on top of the outdoor unit DO NOT operate the air conditioner when using fumigant insecticides The chemicals may beco...

Page 6: ...ing temperatures for safe and effective operation If the air conditioner is used under different conditions it may malfunction or become less efficient COOL Mode HEAT mode DRY mode Indoor Temperature...

Page 7: ...the unit This will reduce the ef ciency of the unit Set a timer and use the built in SLEEP ECONOMY mode if applicable If you don t plan to use the unit for a long time remove the batteries from the r...

Page 8: ...1 Fig 3 2 MANUAL button This button selects the mode in the following order AUTO FORCED COOL OFF FORCED COOL mode In FORCED COOL mode the Operation light ashes The system will then turn to AUTO after...

Page 9: ...m and disconnect the power supply before cleaning or maintenance DO NOT use chemicals or chemically treated cloths to clean the unit DO NOT use benzene paint thinner polishing powder or other solvents...

Page 10: ...h Preparation For Periods Of Non Use Maintenance after Extended Non Use 1 Remove any obstacles blocking the vents of both the indoor and outdoor units 2 Clean the air filter and the front grille of th...

Page 11: ...ting to prevent frost from forming on the unit Once the temperature increases the unit will start operating again The set temperature has been reached at which point the unit turns off the compressor...

Page 12: ...or outdoor unit is dirty Clean the affected heat exchanger The air lter is dirty Remove the lter and clean it according to instructions The air inlet or outlet of either unit is blocked Turn the unit...

Page 13: ...re sensor error 2 On F 1 12 Outdoor condenser pipe sensor error 3 On F2 13 Discharge air temperature sensor error 4 On F3 14 Outdoor EEPROM Electrically Erasable Programmable Read Only Memory error 5...

Page 14: ...dispose of this product as household waste or unsorted municipal waste When disposing of this appliance you have the following options Dispose of the appliance at designated municipal electronic wast...

Page 15: ...bmission has been completed a confirmation message will be sent to your email Full Name Address Postal Code Phone Number E mail Unit Type Serial Number of the unit Date of Purchase Invoice Number Addi...

Page 16: ...4 6 8 SAFETY FIRST 1 3 2...

Page 17: ...9 9 9 10 10 11 11 12 14 4 5 6 R32 R290...

Page 18: ...4 1 R32 R290...

Page 19: ...5 80 8 2 5 m 3 mm RCD 10 mA...

Page 20: ...6 2 17 32 C 62 90 F 0 30 C 32 86 F 17 32 C 62 90 F 0 50 C 32 122 F 15 24 C 5 76 F 0 50 C 32 122 F 15 50 C 5 122 F COOL HEAT DRY 2 1...

Page 21: ...7 AUTO AUTO 24 C 76 F ON OFF SLEEP ECONOMY LCD EC LED...

Page 22: ...8 3 LED PRE DEF PRE DEF LED AUTO FORCED COOL OFF FORCED COOL FORCED COOL AUTO 30 OFF OFF 3 2 3 1...

Page 23: ...9 4 4 N N N N 40 C 104 F 1 2 3 45 4 1 4...

Page 24: ...10 4 5 A 6 7 8 LCD EC LED 1 2 3 12 1 FAN 12 2 3 4 N 4 2 4 3 4 4...

Page 25: ...11 5 ON OFF 3 PRE DEF Fan Only HEAT OFF COOL HEAT COOL FAN...

Page 26: ...12 A 3 7 C 44 5 F...

Page 27: ...1 2 F 1 12 3 F2 13 4 F3 14 5 F4 15 6 F5 16 7 F6 17 8 F7 18 9 F8 19 10 F9 20 1 P0 21 2 P 1 22 3 P2 23 4 P3 24 5 P4 25 6 P5 26 7 P6 27 8 P7 EEPROM EEPROM DC T2b IPM Inverter IGBT Off Off Off Off Off Off...

Page 28: ...14 6...

Page 29: ...email newsletter Inventor l link QR code https www inventoraircondition gr egiisi inventor l email A...

Page 30: ...Cuprins Manual instalare Masuri de siguranta 4 Unitatea interioara si functiile principale 6 Operarea manuala 8 SIGURANTA ARE PRIORITATE 1 3 2...

Page 31: ...12 Sfaturi de depanare 14 Atentie PERICOL DE INCENDIU materiale inflamabile 4 5 5 Lucrarile de service vor fi facute de catre personalul producatorului Lucrarile de mentenanta si reparatie vor fi fac...

Page 32: ...ibere si nu vor fi obstructionate NOTA aceste instructiuni se aplica aparatelor ce folosesc agent frigorific R32 R290 NU perforati si nu ardeti unitatea Unitatea va fi instalata si folosita intr o inc...

Page 33: ...ntru a reduce riscul deficientei de oxigen NU va urcati pe unitataea externa si nu asezati alte obiecte pe aceasta NU utilizati aparatul atunci cand folositi insecticide Substantele chimice se pot dep...

Page 34: ...ranta respectati conditile de mai jos In caz de nerespectare a conditiilor eficienta va scadea si aparatul se poate defecta Temperatura interioara Temperatura exterioara Partile componente ale unitati...

Page 35: ...izator TIMER ECONOMY daca aceste functii sunt disponibile Daca nu veti folosi aparatul pentru o perioada lunga de timp scoateti bateriile din telecomanda Curatati filtrele de aer cel putin o data la 2...

Page 36: ...ntru pre incalzire degivrare PRE DEF indicator pentru pre incalzire degivrare Afisaj LED Buton pentru operare manuala cu acest buton puteti selecta modul de functionare in ordinea urmatoare AUTO FORCE...

Page 37: ...benzen diluant sau pudra pentru lustruire Suprafata se poate crapa deforma NU spalati unitatea sub jet de apa Pericol de soc electric NU folositi apa la o temperatura mai mare de 40 de grade pentru a...

Page 38: ...t si grila frontala a unitatii interioare Montati filtrul in pozitia originala dupa ce a fost curatat si uscat 3 Conectati aparatul la reteaua de energie electrica cu cel putin 12 ore inainte de a l p...

Page 39: ...epornit cand temperatura se schimba La repornirea in modul HEAT dupa degivrare ceata alba poate fi degajata datorita umiditatii generata de procesul de degivrare Un susnet sasait de intensitate scazut...

Page 40: ...tul Inlocuiti siguranta Inlocuiti bateriile Asteptati 3 minute pana sa reporniti aparatul Scadeti temperatura setata Curatati dispozitivul de transfer de caldura afectat Demontati si curatati filtrul...

Page 41: ...nivelul apei Eroare de conexiune intre unitatile interne doar pentru sistemele TWIN Alte defectiuni ale sistemului TWIN Protectie la supratensiune Eroare a senzorului extern de temperatura Eroare la...

Page 42: ...te speciala de colectare a deseurilor electronice La cumpararea unui aparat nou vanzatorul va poate ridica gratuit echipamentul vechi Producatorul va poate ridica produsul vechi gratuit Puteti vinde a...

Page 43: ...ati urmatoarele campuri Activati va garantia l Accesati link ul de mai jos sau scanati codul QR pentru a va activa garantia pe site ul nostru https www inventoraerconditionat ro certificatul de garant...

Page 44: ...CASSETTE TYPE AIR CONDITIONING SYSTEMS Scan here to download the latest version of this manual...

Reviews: