![INVENTOR O1MVI-09WFR Service Manual Download Page 19](http://html1.mh-extra.com/html/inventor/o1mvi-09wfr/o1mvi-09wfr_service-manual_2084086019.webp)
19
5.3 Pipe length and the elevation
The pipe length and refrigerant amount:
Model
Pipe size
Standard
length
(m)
Max.
Elevation
B (m)
Max.
Length
A (m)
Additional
refrigerant
(g/m)
Gas
Liquid
O1MVI-09WFR +
O1MVO-09
3/8’’
(
Ф9.52)
1/4’’
(Ф6.35)
5
10
25
15
O1MVI-12WFR +
O1MVO-12
3/8’’
(
Ф9.52)
1/4’’
(Ф6.35)
5
10
25
15
O1MVI-18WFR +
O1MVO-18
1/2
’’
(Ф12.7)
1/4’’
(Ф6.35)
5
20
30
15
O1MVI-24WFR +
O1MVO-24
5/
8’’
(
Ф15.9)
3/8’’
(
Ф9.52)
5
25
50
30
Caution:
The capacity test is based on the standard length and the maximum permissive length is based on the
system reliability.