INVENTOR APSI-30 Owner'S Manual Download Page 24

Ø

● 

Outdoor condensation drainage (Heat pump type only)

When the unit is heating, the condensing water
and defrosting water can be drained out reliably
through the drain hose.

Installation: Install the outdoor drain elbow in

25 hole on the base plate, and joint the 

drain hose to the elbow, so that the wastewater

formed in the outdoor unit can be drained out

to a proper place.

Chasis

Outdoor drain 

elbow

Install outdoor unit

Fig.

6

Use soap water or leak hunting meter to check whether

the joints is leak.

Indoor unit check point

Out

door unit check point

Leak hunting

Summary of Contents for APSI-30

Page 1: ...ted Unit Owner s Manual Models 66129903948 Thank you for choosing INVENTOR air conditioning system For correct use of this unit please read this manual carefully and keep it for future reference APSI 30 APSO 30 ...

Page 2: ...control Clean and care Troubleshooting Installation service Notices for installation Installation dimension diagram Install indoor unit Install outdoor unit Check after installation and test operation This symbol stands for the items should be forbidden This symbol stands for the items should be followed Emergency operation The figures in this manual may be different with the material objects plea...

Page 3: ...e the accumulated dusts that may cause over heating or fire Never splice the power cord or use an extended cord It can cause overheating or fire When having a burning smell or smoke please turn off the power supply and contact with the service center If the abnormity still exists the unit may be damaged and may cause electric shock or fire Please read the following carefully before operating Notic...

Page 4: ... to them Don t insert your hands or stick into the air intake or outlet vents Don t use the air conditioner for other purposes such as drying clothes preserving foods etc To adjust the airflow direction appropriately When operating the unit to adjust the vertical and lateral air flow direction by use of remote controller Swing louver Guide louver Please don t cut off or damage the power cords and ...

Page 5: ...tdoor temperature becomes very low please operate with other heating equipments Defrosting When outdoor temperature is low but high humidity after a long while running frost will form on outdoor unit that will effect the heating effect at this time the auto defrosting function will act the heat running will stop for 8 10mins During the auto defrosting the fan motors of indoor unit and outdoor unit...

Page 6: ...4 Names and functions of each part Indoor unit Air in Air out Power cable Front panel Filter Guide louver Wall pipe Bind tape Connection wire Drainage pipe Remote control Outdoor unit Air in Air out ...

Page 7: ...t up CLOCK button CLOCK Press this button can set up temperature presetting temperature to display room TEMP button TEMP indoor ambient temperature to display indoor temperature outdoor ambient temperature to display outdoor temperature and that will go around It is defaulted that Operation of wireless remote control Press this button the unit will be turned on press it once more the unit will be ...

Page 8: ...n be button set up continuously press this button and hold for two seconds the relative contents can quickly change until unhold this button and send the order that the o F signal will be displayed all the time The temperature adjustment is unav ailable under the Auto mode but the order can be sent by if pressing this button Names and functions of wireless remote control Operation of wireless remo...

Page 9: ...en the guide louver start to swing up and down if turn off the Swing the air guide louver will stop at current position which indicates the guide louver swings up and down between that all five positions SWING UP and DOWN BUTTON Timer On setting Signal ON will blink and display signal will conceal the numerical section will become the timer on setting status During 5 seconds blink by pressing or b...

Page 10: ...n general operation Guide for operation Optional operation Operation of wireless remote control This function indicates that moisture on evaporator of indoor unit will be blowed after the unit About blow function is stopped to avoid mould 1 Having set blow function on After turning off the unit by pressing ON OFF button indoor fan will continue running for about 10 min at low speed In this period ...

Page 11: ...mode the position will display H1 which flickers for 5s in which case press button H1 will disappear and setting temp be displayed After remote controller is powered on the new defrost function will be defaulted to be closed About swing up and down About lock About new function of defrosting will be displayed on it in which case press any button the mark will Operation of wireless remote control 1...

Page 12: ...erature to select the COOL HEAT FAN mode automatically to obtain the comfortable effect At stopping When the unit is running press the ON OFF button of the manual switch the unit will stop work The code switch can be operated as follow At operation When the unit is stopped running adjust the code switch to AUTO the unit will enter into AUTO RUN mode The microcomputer will accord to the room temper...

Page 13: ...e front panel and take it out forcibly and then can take it off Washing Clean with a soft brush water and neutral dete rgent and then dry it Note Before cleaning the unit please take down the displayer box firstly then to wash the panel if the unit has displayer on the front panel Never use the water above 45 Install front panel Place two supporters of the front panel into the slots along the dire...

Page 14: ...or unit to prevent it from spreading a b Clean and care Take down the air filter Cleaning Reinsert the filters Reinsert the filters along with the arrow head then cover the surface panel and clasp it To clean the dust adhering to the filters you can either use a vacuum cleaner or wash them with warm water the water with the neutral detergent should below 45 When the filters are very dirty such as ...

Page 15: ...n air conditioner is running under cooling mode You may hear a slight crack when the air conditioner is started or stopped The air conditioner itself has no bad smell If any It is the bad smell accumulated from environment Solution Clean the air filter If still any problem the air conditioner shall be cleaned Please contact Authorized Service Center When the air conditioner is started or the compr...

Page 16: ...t of the plug and reinsert it Is it in its receiving range Or obstructed To check the voltage in wireless remote control inside is charged otherwise to replace the batteries Whether the wireless remote control is damaged The air humidity is on the high side Condensing water over flowed The connection position of indoor unit drainage pipe is loosed When the unit is running in COOL mode the pipe and...

Page 17: ...he plug If unit is running under the high humidity for a long time the moisture will be condensed on the air outlet grill and drip off In HEAT mode when the temperature of indoor heat exchanger is very low that will stop deliver air in order to prevent cool air Within 3min In HEAT mode when the outdoor temperature is low or high humidity there are much frost be formed on the outdoor heat exchanger...

Page 18: ... The height of the installed location should be 230 cm or more from the floor 6 Select a place about 1m or more away from TVset or any other electric appliances 7 Select a place where the filter can be easily taken out 8 Make sure that the indoor unit installation should accord with installation dimension diagram requirements Outdoor Unit Installation Position Selection 1 Select a location from wh...

Page 19: ... Make sure that the Live wire or Zero line as well as the earth wire in the family power socket can not be wrong connected there should be reliable and no short circuit in the diagram wrong connection may cause fire The min distance from the unit and combustive surface is 1 5m It should be reliably earthed and it should be connected to the special earth device the installation work should be opera...

Page 20: ...e Above Above Space to the wall Space to the wall Space to the wall Above Above A b o v e m c 0 3 50cm 0 2 0 15cm 15cm 300 cm 2 15 cm Space to the floor Air outlet side Space to the obstruction Air outlet side Air inlet side A b o v e m c 0 2 m c 0 Above 30cm Above cm cm 230 Installation dimension diagram ...

Page 21: ...lood its end by water 3 When the long drainage hose passing through indoor should wrap the insulation materials Wrenched Bent Flooded Indoor Outdoor Wall pipe Seal pad Fig 1 Rear piping hole Rear piping hole Left Right Mark on the middle of it Gradienter Space to the wall 150mm above Space to the wall 150mm above Wall Wall Connect indoor and outdoor electric wires 1 Open the front panel upwardly 2...

Page 22: ... when routing the wiring only 2 Cut off the tailings 1 and tailings 2 when routing both the wiring and piping or 1 2 3 Take out the piping from body case wrap the piping electric wire water pipe with tape and put them th rough the piping hole As show in Fig 3 Hang the mounting slots of the indoor unit on the upper tabs of the rear panel and check if it is firm enough As show in Fig 4 Install the c...

Page 23: ...e then connect the corresponding connector 5 1 0 10 pa 76cmHg 5 Air purging and leakage test Liquid pipe Gas pipe Valve cap Vacuum gauge Vacuum pump Fig 1 Connect charging hose of manifold valve to charge end of low pressure valve both high low pressure valves must be tightly shut 2 Connect joint of charging hose to vacuum pump 3 Fully open handle of Lo manifold valve 4 Open the vacuum pump to eva...

Page 24: ...lation Install the outdoor drain elbow in 25 hole on the base plate and joint the drain hose to the elbow so that the wastewater formed in the outdoor unit can be drained out to a proper place Chasis Outdoor drain elbow Install outdoor unit Fig 6 Use soap water or leak hunting meter to check whether the joints is leak Indoor unit check point Outdoor unit check point Leak hunting ...

Page 25: ...ure earth connection It may cause electrical leakage Is the power cord specified It may cause electric malfunction or damage the part Is the inlet and outlet been covered It may cause insufficient cooling heating capacity Has the length of connection pipes and refrigerant capacity been recorded The refrigerant capacity is not accurate Test Operation 1 Before test operation 1 Do not switch on power...

Page 26: ...filter it is invalid when its surface becomes according to the installation instruction Pay special attention to that silver Take out the healthy filter before cleaning and reinstall it after cleaning Installation and Maintenance of Healthy Filter Healthy filter Air filter Healthy filter downwards to remove it See Fig a the front case as shown in Fig c Fig b Fig c Fig d techin or mite killing filt...

Page 27: ......

Reviews: