Technical Information
3
Service Manual
4
Technical Information
Service Manual
Outdoor
Unit
Outdoor Unit Model
L4VO32-18
Compressor Manufacturer
ZHUHAI LANDA COMPRESSOR
CO.,LTD
Compressor Model
QXF-B141ZF030A
Compressor Oil
68DA
Compressor Type
Rotary
Compressor LRA.
A
25
Compressor RLA
A
6.5
Compressor Power Input
W
1410
Compressor Overload Protector
1NT11L-6233/KSD115
℃
/HPC
115/95
Throttling Method
Electron expansion valve
Set Temperature Range
ºC
16~30
Cooling Operation Ambient Temperature
Range
ºC
-15~43
Heating Operation Ambient Temperature
Range
ºC
-15~24
Condenser Form
Aluminum Fin-copper Tube
Condenser Pipe Diameter
mm
Φ7.94
mm
2-1.4
Condenser Coil Length (LXDXW)
mm
742X38.1X550
Fan Motor Speed
rpm
780
Fan Motor Power Output
W
40
Fan Motor RLA
A
0.62
Fan Motor Capacitor
μF
/
Outdoor Unit Air Flow Volume
m
3
/h
2400
Fan Type
Fan Diameter
mm
Ф445
Defrosting Method
Automatic Defrosting
Climate Type
T1
Isolation
I
Moisture Protection
IPX4
Permissible Excessive Operating Pressure
for the Discharge Side
MPa
4.3
Permissible Excessive Operating Pressure
for the Suction Side
MPa
2.5
Sound Pressure Level (H/M/L)
dB (A)
56/-/-
Sound Power Level (H/M/L)
dB (A)
64/-/-
Dimension(WXHXD)
mm
899X596X378
Dimension of Carton Box (LXWXH)
mm
945X417X630
Dimension of Package(LXWXH)
mm
948X420X645
Net Weight
kg
39
Gross Weight
kg
42
Refrigerant
R32
Refrigerant Charge
kg
0.9
Connection
Pipe
Connection Pipe Length
m
5
Connection Pipe Gas Additional Charge
g/m
16
Outer Diameter Liquid Pipe
mm
Ф6
Outer Diameter Gas Pipe
mm
Ф12
Max Distance Height
m
10
Max Distance Length
m
25
Note: The connection pipe applies metric diameter.
The above data is subject to change without notice. Please refer to the nameplate of the unit.