![Inventor Air Conditioners IKI-09 Owner'S Manual Download Page 12](http://html1.mh-extra.com/html/inventor-air-conditioners/iki-09/iki-09_owners-manual_2084314012.webp)
8
Failure Display
When there is failure in the unit operation, “ERROR”
will flash on the LCD of the wire controller and the code
of failure will also be displayed. When there are
multiple failures at the same time, the codes of failures
will be displayed one after one on the wire controller.
The first digit of the code denotes the system number.
When there is only one system, it will display the syst-
em number 1. The last two digits denote the detailed
failure code. For example, the code in left means low
pressure protection of compressor.
The Codes of Failure Definitions are as Follows:
Fault code
Fault
Fault code
Fault
E0
Pump Failure
F0
Failure of Indoor Room Sensor at Air
Intake
E1
Compressor High Pressure
Protection
F1
Failure of Evaporator Temp. Sensor
E2
Indoor Frost-Proof Protection
F2
Failure of Condenser Temp. Sensor
E3
Compressor Low Pressure
Protection
F3
Failure of Outdoor Ambient Sensor
E4
Compressor Exhaust High
Temperature Protection
F4
Failure of Exhaust Temp. Sensor
E5
Compressor Overheat
F5
Failure of Indoor Room Sensor at Wire
Controller
E6
Communications Failure
E8
Indoor Fan Protection
E9
Full Water Protection
E5 Material Malfunction Will Be Showed By The Indicator Light On The Mother Board Of Outside Unit
SWING
R
Summary of Contents for IKI-09
Page 1: ...66129903851 IKI 09 IKI 12 IKI 18 IKI 24 IKI 36 IKI 45 IKI 50 Floorceiling Unit...
Page 2: ......
Page 4: ......
Page 35: ...PRECAUTIONS OPERATION INSTRUCTIONS22...
Page 40: ...Outdoor Unit Installation CAUTION INSTALLATION INSTRUCTIONS Fig 31 Fig 32...
Page 48: ...PIPE PREPARATION OPERATION INSTRUCTIONS...
Page 50: ...AIR PURGING AND CHECK OF PIPE LEAKAGE OPERATION INSTRUCTIONS...
Page 51: ...LIQUID PIPE AND DRAIN PIPE OPERATION INSTRUCTIONS...
Page 52: ...DRAIN PIPING WORK OPERATION INSTRUCTIONS45...
Page 55: ......