SYSTEM OVERVIEW: PURE CONTROLLER

7

Pure controller | Installation instructions

2.1  Function

The Pure controller is a control unit for decentralised ventilation units with heat recovery from 

inVENTer GmbH. Where these are connected, the information determined at the controller via the 

sensor technology is incorporated into the control of the ventilation unit.

If no sensor is connected (basic control unit), the operating mode and intensity of the air flow can 

be set on the Pure controller.

Possible operating modes:

•  Heat recovery

•  Ventilation

•  Pause timer

•  OFF (p4 and p4 Fire only)

There are three ventilation levels for the ventilation units which define the rotational speed of the 

fans and therefore the units' air flow. These are fixed and cannot be changed:

•  Ventilation level 1 – 25 %

•  Ventilation level 2 – 50 %

•  Ventilation level 3 – 100 %

If sensors are connected to the Pure controller, the range of the controller's functions increases 

and this also allows demand-based ventilation alongside manual ventilation.

The sensor used must have a potential-free relay contact as its output.

The increase in functions depends on the variant of controller:

Controller 

variant

Sensor

Limit value exceeded  

Limit value not reached

p4

p4 Flat

CO

2

 sensor

Switch all ventilation units 

connected to the controller to 

ventilation mode,  

output level 75 %.

Switch all ventilation units con-

nected to the controller to the 

originally set operating mode 

and ventilation level.

VOC sensor
Humidistat

p4 Fire

p4 Fire 

Flat

Pressure 

sensor  

(4 Pa) 

Switch all ventilation units 

connected to the controller to 

OFF mode.

1  a 

Flush-mounted switching  

 

power supply unit, or 

DIN rail switching power  

 

supply unit

2   

Mounting box

3   

Control module

4   

Display LED (RGB LED) 

 

LED red: Heat recovery 

 

LED green: Ventilation

5   

Switch, programming unit

Summary of Contents for Pure

Page 1: ...www inventer de Operating Instructions Pure Control unit ...

Page 2: ...erefore no guarantee of compliance can be provided This documentation describes the functionality of the standard scope For reasons of clarity the documentation does not purport to cover all details on all types of the product and cannot cover every conceivable scenario for commissioning operation cleaning and care The illustrations in this document may differ slightly from the design of the produ...

Page 3: ...3 1 General information 8 3 2 Setting the ventilation level 9 3 3 Switching off the ventilation 10 3 4 Setting heat recovery ventilation mode 11 3 5 Activating deactivating the pause timer 12 3 6 Acknowledging a filter change 13 3 7 Sensor technology activated 14 4 Cleaning and care 15 5 Accessories and spare parts 16 6 Troubleshooting and disposal 17 7 Guarantee and warranty 18 8 Service 18 TABLE...

Page 4: ... danger unless the preventive measures are taken WARNING means Possible danger of serious injury or death CAUTION means Direct danger of minor significant injury NOTICE means Direct or possible risk of property damage due to an adverse event state If you see these signs ensure you observe the described measures to prevent possible hazards and or damage Other symbols used in this documentation In a...

Page 5: ...ed and named by inVENTer GmbH in this documentation Changes or modifications to the units are not permitted Your ventilation system is exclusively designed for use in ambient temperatures between 20 and 50 C Proper operation and maintenance are required for trouble free and safe operation of the equip ment system These operating instructions are only valid in conjunction with the installation inst...

Page 6: ...or p4 Fire Integration of a safety device e g pressure monitor with simultaneous operation of the ventilation units with fireplaces Components The Pure controller consists of a control module with connecting terminals which contain the electronics for controlling the connected ventilation units two status LEDs for visual feedback for the user as well as a switching power supply unit A serial or do...

Page 7: ...evel 2 50 Ventilation level 3 100 If sensors are connected to the Pure controller the range of the controller s functions increases and this also allows demand based ventilation alongside manual ventilation The sensor used must have a potential free relay contact as its output The increase in functions depends on the variant of controller Controller variant Sensor Limit value exceeded Limit value ...

Page 8: ...adjusted by changing the switch positions The display LED RGB LED The display LED is located behind the rocker switches and shows the state of the controller with different colours The following displays are possible LED colour LED state Status of the controller Presentation RED Lights up solid Heat recovery mode active 11 RED Flashing Safety device sensor triggered 14 GREEN Solid Ventilation mode...

Page 9: ... ventilation levels are defined Ventilation level 1 25 Ventilation level 2 50 Ventilation level 3 100 The new setting takes effect immediately so that adjustments can be made purely by listening to changes in the sound level Ventilation level 1 Ventilation level 2 Ventilation level 3 Only the left hand rocker switch is pressed Only the right hand rock er switch is pressed Both rocker switches are ...

Page 10: ...positions Switching off the ventilation unit Switching the ventilation unit back on Select any of the ventilation levels 1 3 Ö All of the ventilation units connected to the control ler restart at the selected ventilation level Switch both rocker switches off Ö All of the ventilation units connected to the control ler are switched off In individual cases after the ventilation unit has been switched...

Page 11: ...e of the air inside The outdoor air flowing in is pre warmed by being fed over the ceramic thermal accumulator before making its way indoors On summer days this is also recommended The higher outdoor temperature compared to the indoor temperature means that the supply of heat is significantly re duced during ventilation Ventilation mode In this mode the reversible fans do not change their directio...

Page 12: ...ithin around 2 seconds switch back and forth quickly Ö The pause timer is activated deactivated Select the ventilation level at which the ventilation unit is to operate after the pause If the OFF switch setting is selected the reversible fans do not start after the pause Select one of the ventilation levels 1 3 to ensure ventilation Reversible fan Pause timer Not working Active Working Not active ...

Page 13: ...e the operating instructions for your particular ventilation unit To do this pause the ventilation unit Move both rocker switches to the same position OFF or ventilation level 3 Simultaneously switch both rocker switches back and forth twice from their current position All switching operations must be carried out within around 2 seconds switch back and forth quickly Ö Both LEDs go out Ö The LED to...

Page 14: ...the controller restart in the originally set operating mode and ventilation level Integrating a safety device p4 Fire p4 Fire Flat versions The external interface is used to integrate safety devices e g a 4 Pa pressure sensor into the ventilation system while simultaneously operating the ventilation system with fireplaces WARNING For joint operation with fireplaces safety measures must be taken to...

Page 15: ...ructions TIP Disconnect the power supply for any cleaning or care work Detergents NOTICE Due to the controller s scratch sensitive plastic surface damage may occur to the surface To prevent damage to the surface do not use sand soda acid or chlorine based cleaning agents A commercially available detergent in warm water can be used for cleaning The following tools may be used for cleaning lint free...

Page 16: ...1004 0210 Control module incl LEDs1 2008 0013 p4 2008 0015 p4 Flat 2008 0016 p4 Fire 2008 0017 p4 Fire Flat Sensor technology optional CO2 sensor CS1 1004 0145 HYG18 humidistat 1002 0044 HYG12 humidistat 1002 0015 Switching power supply units Switching power supply unit NT17 s8 for DIN rail installation 3002 0275 Flush mounted switching power supply unit NT17 Mz s8 3002 0267 1 The controller versi...

Page 17: ...level 75 LED flashes alternately red and green Indicator for filter change Clean replace the filter If you cannot eliminate the fault please contact our technical customer service You can find information about doing so in section 11 Service Dismantling and disposal Dismantle the controller before disposal Your Pure controller contains valuable materials that can be recovered and recy cled The sep...

Page 18: ...e 8 Service Claims Check the delivery for completeness and transport damage upon receipt using the delivery note Report missing items immediately and at the latest within 14 days to your supplier distributor or factory representative Warranty and guarantee claims In the case of a warranty or guarantee claim contact your local distributor or factory representative In all cases please return the com...

Page 19: ...19 GUARANTEE AND WARRANTY 19 Pure controller Installation instructions NOTES ...

Page 20: ...Item number 5021 0021 Version 1 0 02 2022 Subject to modifications We accept no liability for printing errors inVENTer GmbH Ortsstraße 4a 07751 Löberschütz Germany www inventer de ...

Reviews: