background image

Invacare

®

 RPS 440ee

Instruction Manual

Version 07/08

DEALER: 

This manual MUST be given to the user of the patient lift.

USER: 

BEFORE using this patient lift, read this manual and save for future reference.

SERVICE AGENT: 

Only Invacare authorised service agents are permitted to install, 

service or repair Invacare product.

Summary of Contents for RPS 440ee

Page 1: ...R This manual MUST be given to the user of the patient lift USER BEFORE using this patient lift read this manual and save for future reference SERVICE AGENT Only Invacare authorised service agents are...

Page 2: ......

Page 3: ...Emergency Stop Button OFF while transmission is in progress This product meets EN60601 1 2 Collateral Standard Electromagnetic Compatibility WARNING notices as used in this manual apply to hazards or...

Page 4: ...ic RPS 440ee User s Manual Special Notes ALWAYS be aware of the Lift Arms Injury to the patient and or assistant may occur ALWAYS be aware of the Footrest especially the patient s position on the foot...

Page 5: ...ocking Unlocking the Rear Swivel Casters 12 Raising Lowering Stand Up Lift 12 Closing Opening the Legs of the Base 12 Mounting Battery Charger 13 Charging the Batteries 14 Transferring From 15 Lifting...

Page 6: ...reach at min height of C S P NA 11 Max hoisting reach NA 12 Base Base Radial type 1 Max external length 1140 2 Max internal length 820 3 Min internal width 575 4 Min external width 675 5 Max internal...

Page 7: ...acare Stand Up Lift Slings and accessories designed by other manufacturers or other Invacare slings are not to be utilized as a component of Invacare s stand up lift system Use of these products is pr...

Page 8: ...he sling is properly connected to the attachment points of the stand up lift If any attachments are NOT properly in place lower the patient back onto the surface and correct this problem During transf...

Page 9: ...n the European Market It indicates that the product complies with applicable European Directives related to health safety environment and consumer protection Safe Working Load Represents the maximum l...

Page 10: ...es you can is a trademark of Invacare Corporation 2008 Invacare Asia Pacific RPS 440ee User s Manual Documentation With each lifter you should receive the following documents this Instruction Manual a...

Page 11: ...using the previously removed bolts Note Ensure these bolts are firmly tightened Attach the rod ends as shown in 2 Cut cable tie securing actuator 3 and swing actuator forward so that it is out of the...

Page 12: ...clevis and restrict the pivot Attaching the kneepad Attach the kneepad to the kneepad receiver by sliding the two posts into the tube retainers of the kneepad receiver assembly and at the same time t...

Page 13: ...ion Invacare is a registered trademark andYes you can is a trademark of Invacare Corporation 2008 Invacare Asia Pacific Ensure control box emergency push button is set to the off position out If not t...

Page 14: ...patient NOTE If the Stand Up Lift is in the full UP position it may be necessary to pull down slightly on the lift arms before the mast will lower EMERGENCY STOP Press the RED button on the control b...

Page 15: ...h mounting bracket on the wall at the desired position 2 With a pencil mark the MIDDLE hole position 3 Measure down 6 1 2 inches from the pencil mark and drill one 1 mounting hole 4 Install the BOTTOM...

Page 16: ...ay from the control box 3 Place the battery on the battery charger as shown in the following diagram Make sure there is an audible click NOTE The charge LED will illuminate When charging is complete c...

Page 17: ...elf when the patient is initially lifted from and transferred to a chair bed or any stationary object Transferring From Lifting Preparation NOTE The stand up lift may be operated by one 1 healthcare p...

Page 18: ...s MUST be in the locked position BEFORE lowering the patient into the wheelchair STANDING SLINGS DO NOT use the standing sling in combination with the stand up lift as a transport device It is intende...

Page 19: ...his her own weight However since medical conditions vary Invacare recommends that the healthcare professional evaluate the need for assistance and determine whether more than one 1 assistant is approp...

Page 20: ...button to raise the patient above the surface of the bed The patient should be elevated just high enough to clear the bed with their weight fully supported by the lift 2 Press the DOWN button and low...

Page 21: ...lings Unhook the transport sling from the bottom attachment points on the stand up lift Lift up on the patient s legs and remove the thigh supports from underneath the patient If desired unhook the tr...

Page 22: ...n accordance with the following schedule of Service Types Item Pre Delivery Daily Minor Service After every 3 Months of Service Major Service After every 6 Months of Service PRE DELIVERY Confirm all c...

Page 23: ...D HARDWARE CHECK ALL SLING ATTACHMENTS each time it is used to ensure proper connection and patient safety X X X X Inspect sling material for wear X X X X Inspect straps for wear X X X X CLEANING When...

Page 24: ...to lift when button is pressed Hand control or actuator connector loose Batteries low RED emergency stop button pressed IN Battery not connected properly in to control box The connecting terminals are...

Page 25: ...lts for tightness Remove all debris etc from the wheel and swivel bearings If any parts are worn replace these parts immediately If you question the safety of any part of the lift contact your Dealer...

Page 26: ...o clean the patient lift The lift can be cleaned with non abrasive cleaners Electric Actuator Replacement 1 Remove the nut washer and shoulder bolt that secure the electric actuator to the mast mounti...

Page 27: ...efective unit or parts MUST be returned for warranty inspection using the serial number when applicable as identification within 30 days of return authorization date Do not return products to our fact...

Page 28: ...f inspection reveals that user safety is jeopardised in any way from use of the patient lifter Ensure ongoing servicing after the Warranty Period is maintained by agreement between you and an Authoris...

Page 29: ...onTaken Inspected By Signature Date ServiceType Pre Delivery Minor Periodic Inspection Major RPS 440ee User s Manual All information is subject to change without prior notice Photographs are for illus...

Page 30: ...y Signature Date ServiceType Pre Delivery Minor Periodic Inspection Major All information is subject to change without prior notice Photographs are for illustration purposes only and may vary from pro...

Page 31: ...y Signature Date ServiceType Pre Delivery Minor Periodic Inspection Major RPS 440ee User s Manual All information is subject to change without prior notice Photographs are for illustration purposes on...

Page 32: ...y Signature Date ServiceType Pre Delivery Minor Periodic Inspection Major All information is subject to change without prior notice Photographs are for illustration purposes only and may vary from pro...

Page 33: ...y Signature Date ServiceType Pre Delivery Minor Periodic Inspection Major RPS 440ee User s Manual All information is subject to change without prior notice Photographs are for illustration purposes on...

Page 34: ...y Signature Date ServiceType Pre Delivery Minor Periodic Inspection Major All information is subject to change without prior notice Photographs are for illustration purposes only and may vary from pro...

Page 35: ...subject to change without prior notice Photographs are for illustration purposes only and may vary from product description Invacare is a registered trademark andYes you can is a trademark of Invacare...

Page 36: ...ax 0508 807 788 Email sales invacare co nz Web www invacare co nz InvacareAsia Ltd 1 Lenton Place PO Box 5002 North Rocks NSW 2151 Australia Phone 61 2 8839 5330 Fax 61 2 8839 5331 Email asiasales inv...

Reviews: