background image

Safety

2 Safety

2.1 General Safety Information

This section of the manual contains general safety
information about your product. For specific safety
information, refer to the appropriate section of the manual
and procedures within that section.

WARNING!
Risk of injury or damage

– Do not use this product or any available optional

equipment without first completely reading
and understanding these instructions and any
additional instructional material such as user
manuals or instruction sheets supplied with
this product or optional equipment. If you are
unable to understand the warnings, cautions or
instructions, contact a healthcare professional,
Invacare provider or qualified technician before
attempting to use this product.

– Do not make any unauthorized alterations or

modifications to the product.

WARNING!
Risk of entrapment / suffocation

There’s a risk of entrapment / suffocation
between mattress support, side rail and bed end
or between moving parts and objects placed
nearby the bed.

– The bed, in combination with side rails must

not be used by persons having a body size
outside the ranges specified in

3.1 Intended

Use, page 9

.

– Due to mattress compression, an increased

risk may occur over time. Periodically monitor
gaps between the bed, mattress and/or side
rail. Replace mattress if the gaps may lead to
entrapment.

WARNING!
Risk of slipping through the openings

The bed fulfils all requirements regarding
maximum distances. However, it is possible
that persons with small body dimensions slip
through the openings between the side rails or
through the opening between the side rail and
the mattress support.

– Pay special attention, if the bed is used for the

care of persons with small body dimensions.

WARNING!
Risk of injury or damage

Inappropriate handling of cables, incorrect
connections and use of unauthorized equipment
can cause electrical shock and product failure.

– Do not kink, shear or otherwise damage the

cables of the product.

– Make sure that no cables are jammed or

damaged, when the product is used.

– Disconnect the plug from the mains before

moving the bed.

– Make sure the wiring is correct and connections

are proper.

– Do not use unauthorized equipment.

WARNING!
Risk of tripping, entanglement or strangulation

Improper routing of cables may cause tripping,
entanglement or strangulation hazard.

– Ensure all cables are routed and secured

properly.

– Ensure there are no loops of excess cable

extending away from the product.

WARNING!
Risk of injury or damage

Ignition sources can cause burns or fire.

– Bed must be placed with a safety space from

possible ignition sources (heater, fireplace, etc.)

– Persons using or operating the product must

not smoke.

WARNING!
Risk of injury or damage

Improper use of this product may cause injury
or damage.

– Do not use the bed for the transportation of a

user in any kind of vehicle.

WARNING!
Risk of entrapment or tipping

Objects or equipment in close proximity or
attached to the bed my cause tipping or
entrapment.

– Make sure that there is nothing under, over,

near or attached the bed that can cause tipping
of the bed or entrapment of the user.

WARNING!
Risk of injury or damage

To avoid injury or damage when operating the
product:

– Close supervision is necessary when the product

is used near children or pets.

– Do not let children play with the product.

WARNING!
Risk of entrapment

When lifting or lowering the bed, there’s a risk
of entrapment between mattress support, shear
arms and base frame.

– Never leave children unattended playing around

the bed.

– Do not allow children to linger under the bed.
– When lifting or lowering the bed, always make

sure that there is no children near the bed
moving parts.

60126224-A

5

Summary of Contents for NordBed Kid

Page 1: ...Invacare NordBed Kid en Children s Bed User Manual This manual MUST be given to the user of the product BEFORE using this product this manual MUST be read and saved for future reference...

Page 2: ...whole or in part is prohibited without prior written permission from Invacare Trademarks are identified by and All trademarks are owned by or licensed to Invacare Corporation or its subsidiaries unles...

Page 3: ...ail with Foldable Doors 12 4 6 Manual positioning of the leg section 14 4 7 Emergency positions 15 4 7 1 Emergency release of a mattress support section 15 4 8 Transportation and Storage 15 5 Maintena...

Page 4: ...dicates a hazardous situation that could result in damage to property if it is not avoided Tips and Recommendations Gives useful tips recommendations and information for efficient trouble free use 1 2...

Page 5: ...injury or damage Inappropriate handling of cables incorrect connections and use of unauthorized equipment can cause electrical shock and product failure Do not kink shear or otherwise damage the cabl...

Page 6: ...s of 400 mm or less the base of some mobile patient lifts might not fit under the bed It might be required to use mobile patient lifts with a smaller base or other transfer methods IMPORTANT Accumulat...

Page 7: ...served to verify that they are operating normally This bed can be used together with Invacare approved accessories and medical electrical equipment connected to the heart intracardially or blood vesse...

Page 8: ...fe working load applied Temperature limit Humidity limitation Atmospheric pressure limitation Transport and storage conditions Operation conditions Indicates the correct body position in the bed Refer...

Page 9: ...C D E F G J K L M N O I H Parts of standard bed A Back section B Seat section C Thigh section D Leg section E Bed end F Hand Control Box G Height adjustment actuator H Back section actuator I Leg sect...

Page 10: ...Move the bed to its correct position 2 Connect the bed to the mains 4 3 Castors and brakes CAUTION Risk of trapping squeezing All brakes are foot operated Do not release the brake with the fingers CAU...

Page 11: ...ection Thigh section Up p Raise the tight section Down q Lower the tight section Leg section Up p Raise the leg section Down q Lower the leg section Locking Function The locking function prevents usag...

Page 12: ...owering the side rail with the bed in a low position or when lowering the bed with the side rail down Lowering the Side Rail 1 3 2 2 1 Slightly pull and hold the top bar upwards with both hands 2 Push...

Page 13: ...r on the underside and fold the door 2 b a On the other door press the lever on the underside and fold the door 3 a b c Pull out the pin rotate clockwise by 90 degrees and release it to position the t...

Page 14: ...to position the tab in the vertical slot 3 a b CLICK Unfold the door without the latch on the top bar and ensure the locking mechanism on the underside engages with an audible click 4 b c CLICK a CLI...

Page 15: ...emergency release of the height adjustment is NOT possible CAUTION Risk of injury A minimum of two persons is required for an emergency release of a mattress support section When releasing a mattress...

Page 16: ...ns if applicable When cleaning electronic components consider their protection class regarding water ingress Make sure that no water splashes to the plug or the wall outlet Do not touch the power sock...

Page 17: ...olstery and mattresses See attached label on each product 5 3 4 Disinfection Instructions Information on recommended disinfectants and methods can be found on https vah online de en for users In Domes...

Page 18: ...ing of used products and packaging must comply with the laws and regulations for waste handling in each country Contact your local waste management company for information 6 2 Reconditioning This prod...

Page 19: ...Ensure hand control correctly connected to control unit Hand control defective Call dealer technician to replace hand control Control unit defective Call dealer technician to replace control unit Full...

Page 20: ...Seat section length E 7 13 15 Thigh section length F 16 18 23 Leg section length G 48 55 57 Total length H 146 166 185 Total height I with low bed ends 71 121 Total height I with high bed ends 111 16...

Page 21: ...e with castor breaks 30 30 30 Bed End 40 cm height 7 Bed End 80 cm height 12 Fixed side rail 40 cm height 8 9 Fixed side rail 80 cm height 10 11 12 Lowering side rail 40 cm height 8 9 Side rail with f...

Page 22: ...Alternating current Maximum current input Iin max 2 5 A 228 282 VA Intermittent periodic motor operation 10 max 2 min ON 18 min OFF Insulation class CLASS II equipment Type B Applied Part Applied Par...

Page 23: ...uct uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class B This...

Page 24: ...netic site survey should be considered If the measured field strength in the location in which this product is used exceeds the applicable RF compliance level above this product should be observed to...

Page 25: ...800 WLAN 802 11 a n Pulse modulation b 217 Hz 0 2 0 3 9 If necessary to achieve the immunity test level the distance between the transmitting antenna and the Medical Electrical Equipment or System may...

Page 26: ...Notes...

Page 27: ...Notes...

Page 28: ...Fax 353 1 810 7085 ireland invacare com www invacare ie United Kingdom Invacare Limited Pencoed Technology Park Pencoed Bridgend CF35 5AQ Tel 44 0 1656 776 222 Fax 44 0 1656 776 220 uk invacare com ww...