Safety

2 Safety

2.1 General safety information

This section of the manual contains general safety
information about your product. For specific safety
information, refer to the appropriate section of the manual
and procedures within that section.

WARNING!
Risk of injury or damage

– Do not use this product or any available optional

equipment without first completely reading
and understanding these instructions and any
additional instructional material such as user
manuals or instruction sheets supplied with
this product or optional equipment. If you are
unable to understand the warnings, cautions or
instructions, contact a healthcare professional,
Invacare provider or qualified technician before
attempting to use this product.

– Do not make any unauthorized alterations or

modifications to the product.

WARNING!
The maximum safe working load must not be
exceeded

– Do not exceed the maximum safe working load

of this product or used accessories like slings,
spreader bars etc. See documentation or the
labeling for the stated maximum safe working
load.

– The component with the lowest load limit

determines the maximum safe working load of
the entire system.

WARNING!
Risk of injury or damage

Improper use of this product may cause injury
or damage.

– Do not attempt any transfer without approval

of the patient’s healthcare professional.

– Read the instructions in this user manual and

observe trained personnel performing transfer
procedures. Then practice transfers under
supervision and with a capable person acting
as a patient.

– Special care must be taken with people with

disabilities who cannot cooperate while being
transferred.

– Do not use the lift as a transport device. It

is intended to transfer an individual from one
resting surface to another.

WARNING!
Risk of injury or damage

Inappropriate handling of cables can cause
electrical shock and product failure.

– Do not kink, shear or otherwise damage the

cables of the product.

– Make sure that no cables are jammed or

damaged, when the product is used.

– Make sure the wiring is correct and connections

are proper.

– Do not use unauthorized equipment.

WARNING!
Risk of injury or damage

Excessive moisture will damage the product and
may cause electrical shock.

– The patient lift can be used in a bath or shower

area but must NOT be used under the shower.
The patient must be transferred to a shower
chair or use other means for showering.

– If the patient lift is used in a moisture

environment, ensure that the patient lift is
wiped clean of any moisture after use.

– Do not plug or unplug the power cable in a

moisture environment or with wet hands.

– Do not store the product in a damp area or

damp condition.

– Periodically inspect all components of the

product for signs of corrosion or damage.
Replace parts that are corroded or damaged.

– See

11.4 Environmental conditions, page 32

.

WARNING!
Risk of injury or damage

Ignition sources can cause burns or fire.

– Patient transfer must be performed with a

safety space between the lift and possible
ignition sources (heater, stove, fireplace, etc.)

– The patient and assistants must not smoke

during transfer.

– The sling must not be placed over heat sources

(heater, stove, fireplace, etc.)

WARNING!
Risk of injury or damage

To avoid injury or damage when operating the
product:

– Close supervision is necessary when the product

is used near children or pets.

– Do not let children play with the product.

CAUTION!
Risk of injury or damage

The product can get hot when exposed to sunlight
or other heat sources.

– Do not expose the product to direct sunlight for

prolonged periods.

– Keep the product away from heat sources.

IMPORTANT!

Accumulation of lint, dust and other dirt can
impair the product.

– Keep the product clean.

2.1.1 Pinch points

60128520-A

5

Summary of Contents for Birdie EVO

Page 1: ...EVO Birdie EVO COMPACT Birdie EVO PLUS Birdie EVO XPLUS en Mobile Patient Lift User Manual This manual MUST be given to the user of the product BEFORE using this product this manual MUST be read and...

Page 2: ...ation duplication or modification in whole or in part is prohibited without prior written permission from Invacare Trademarks are identified by and All trademarks are owned by or licensed to Invacare...

Page 3: ...t 15 5 6 4 Activating an emergency lifting CBJ Care CBJ1 control unit 15 5 6 5 Activating a mechanical emergency lowering 15 5 7 Charging the battery 16 5 7 1 CBJ Home control unit 16 5 7 2 CBJ Care C...

Page 4: ...ous situation that could result in damage to property if it is not avoided Tips and Recommendations Gives useful tips recommendations and information for efficient trouble free use 1 2 Service Life Th...

Page 5: ...NING Risk of injury or damage Inappropriate handling of cables can cause electrical shock and product failure Do not kink shear or otherwise damage the cables of the product Make sure that no cables a...

Page 6: ...ment must consider The patient s weight size physical ability and medical condition The type of transfer and the environment The compatibility to the other lifting equipment used 2 3 Safety informatio...

Page 7: ...king load Class II equipment Type B applied part WEEE conform European Conformity Medical device Abbreviations for technical data Iin Incoming Current Uin Incoming Voltage Int Intermittence AC Alterna...

Page 8: ...ty limitation Atmospheric pressure limitation Transport and storage conditions Operation conditions Always ensure that the sling is properly attached to the hooks See 6 2 1 Attaching the sling to the...

Page 9: ...roduct 3 2 Main parts of the lift A Boom B Spreader bar with or without SMARTLOCK C Hook for sling D Push bar E Lifting actuator F Mast foldable or fixed G Base with foot pedal for manual leg spreader...

Page 10: ...ar control unit and actuators with foldable mast 1 piece with fixed mast 2 pieces base as a separate part B Hand control 1 piece Mains cable 1 piece User Manual 1 piece Battery 1 piece CBJ Care CBJ1 a...

Page 11: ...mast only WARNING Risk of injury or Damage The maximum safe working load stated on the boom and on the base must be the same Always compare the maximum safe working load values stated on the base and...

Page 12: ...ast and fit it to the boom mounting bracket C 3 Align the holes and reinstall the pin A Make sure that the pin is completely inserted and secure it with the D clip IMPORTANT Due to higher loads Birdie...

Page 13: ...llow during daily usage or after a reassembly the lift requires service Contact your Invacare provider for service After the initial assembly of the lift the service indicator needs to be reset before...

Page 14: ...and assistants The legs of the lift must be in the maximum open position for optimum stability and safety If it is necessary to close the legs of the lift to maneuver the lift under a bed close the l...

Page 15: ...s the button 1 Lower the boom by pressing and holding button A at the front of the control unit 2 Stop lowering the boom by releasing the button 5 6 4 Activating an emergency lifting CBJ Care CBJ1 con...

Page 16: ...BJ Home control unit The control unit is equipped with a sound signal A beep indicates that the battery has low capacity but lowering the patient is still possible It is recommended to charge the batt...

Page 17: ...he boom 5 7 3 Optional hand control For CBJ Care a optional hand control with battery indicator is available Battery Indicator Type Battery State Description Full Charge The battery is OK no need for...

Page 18: ...ger as shown and make sure there is an audible click B When the battery is placed on the charger the charge LED will illuminate When charging is complete charge LED will switch off A battery needing t...

Page 19: ...the hand control properly when not in use WARNING Risk of Entrapment or Strangulation Items in the patient s surroundings can cause entrapment strangulation during lifting To avoid entrapment or stran...

Page 20: ...of the sling during transfer Make sure that there is sufficient head support when lifting a patient Position the patient in the sling as directed by the instructions provided with the sling Adjustmen...

Page 21: ...is her feet rest on the base of the lift straddling the mast The lower center of gravity provides stability making the patient feel more secure and the lift easier to move 10 Move the patient lift wit...

Page 22: ...an withstand the patient s weight The wheelchair wheel locks MUST be in a locked position before lowering the patient into the wheelchair for transport 1 Perform the following steps in addition to tho...

Page 23: ...achment 6 Raise the patient off of the commode 7 When the patient is clear of the commode surface use the push bars to move the lift away from the commode 8 Proceed with the transfer to another restin...

Page 24: ...the sling straps inside of the legs of the lift 7 Lower the boom so the spreader bar is directly over the patient s chest 8 Attach the sling See 6 2 1 Attaching the sling to the lift page 20 9 Raise t...

Page 25: ...d in 4 5 Installing the actuator to the boom page 12 5 Reverse the procedure described in 4 4 Unfolding the spreader bar page 11 6 Reverse the procedure described in 4 3 2 Assembling the mast to the b...

Page 26: ...Take precautions for yourself and use appropriate protective equipment CAUTION Risk of electric shock and product damage Switch off the device and disconnect from mains if applicable When cleaning el...

Page 27: ...specified therein 8 4 Service interval WARNING Risk of injury or damage Service must be performed only by a qualified technician Contact your Invacare provider for service Service must be performed a...

Page 28: ...1 Technical Data page 30 Be environmentally responsible and recycle this product through your recycling facility at its end of life Disassemble the product and its components so the different material...

Page 29: ...ency stop button is pressed in Rotate the emergency stop button clockwise until it pops out Battery not connected properly to control unit Reconnect the battery to the control unit See 5 7 4 Optional...

Page 30: ...rom base b 630 630 530 530 630 Base length c 1200 1220 1060 1080 1280 Total length without lever n 1250 1250 1100 1100 1280 Total length with lever l 1290 1290 1140 1140 1350 Reach from base with legs...

Page 31: ...dable version only 1300 1320 1190 1210 1360 CSP Central Suspension Point All measures are taken with a 450 mm 2 point spreader bar Weights Main Parts kg Birdie EVO Birdie EVO COMPACT Birdie EVO PLUS X...

Page 32: ...ronmental conditions Storage and transportation Operation Temperature 10 C to 50 C 5 C to 40 C Relative humidity 20 to 90 at 30 C not condensing Atmospheric pressure 800 hPa to 1060 hPa Allow the prod...

Page 33: ...duct uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class B Thi...

Page 34: ...ions for radio cellular cordless telephones and land mobile radios amateur radio AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy To assess the electromagneti...

Page 35: ...Notes...

Page 36: ...445 38 00 34 italia invacare com www invacare it Nederland Invacare BV Galvanistraat 14 3 NL 6716 AE Ede Tel 31 0 318 695 757 Fax 31 0 318 695 758 nederland invacare com www invacare nl Belgium Luxemb...

Reviews: