EN-V233 – 5004 – AA Installation and use of call panel + key safe EEN-PVIBCV3
Page 9 / 12
POST-FITTING CHECK
Before leaving the fitting, the following points should be checked:
D)
O
N THE
P
ANEL
- Display shows the welcome message
- Check that the keypad keys (0, 1, 2
9, * and #) work.
Procedure:
o
Press #; the display shows "Call number"
o
The numeric keys must be displayed correctly
o
Finish using the * key; the display should return to the welcome message.
- Check that the keypad keys are backlit.
E)
D
OOR CONNECTION
- Check door opening with the push button
- Check door opening using a badge
(See Test Procedure in the central unit guide)
F)
C
ALLS
- Check the quality of a call by a visitor to a resident:
o
Audio Call
o
Video Call
- Check that, during the call, the resident can open the door by pressing the * key on
his/her telephone
(See Test Procedure in the central unit guide)
G)
I
N THE CASE OF A FITTING WITH A
3G
UNIT
If you use a 3G unit with your call panel, you can see the signal reception level for the unit
by pressing the 2 scrolling arrow keys
֠
֠
֠
֠
on the display.
Depending on the situation, you will see:
"3G NET Lev
17
3
" or "GSM NET Lev
17
3
»
- NET : shows that the network has been found by the unit (3G or GSM)
- Lev
: shows the level out of 30 (here,
17
/ 30) and the connection on a scale of 5
(here
3
/ 5)
Press one of the arrow keys to exit from this menu.
H)
I
N THE CASE OF A FITTING WITH A
EEN-CIC12
CENTRAL UNIT
Remember to make a note of the serial number (7XXXXXX3) of the central unit.
You will need this to go back into the installation and configure these settings on the
keypad outside.