background image

Page 2 / 6  

installation and user guide for the Intratone EEN-REC2   

V233-0011-AD receiver 

Anti-passback operation 

 

Anti-passback  controls  the  2  ENTRY  and  EXIT  doors  to  prevent  unauthorised  entries.  The  resident  must 
therefore have left via the EXIT door before again being allowed access to the car park via the ENTRY door.  
The  anti-passback  function  works  by  setting  an  anti-passback  time  during  which  any  new  attempt  to  gain 
access via the ENTRY door is systematically denied. Access via the ENTRY door will be authorised again, 
either after this time has expired, or once the resident has left via the EXIT door.  

 

The anti-passback function is only activated with the combined use of: 

-

 

An EEN-REC2 receiver 

-

 

An INTRATONE RESIDENTIAL central unit (or GSM Edge module)  

-

 

Vehicle detection loops on ENTRY and EXIT. 

 

And it only works with remote controls to which anti-passback apply (see 

www.intratone.com

).   

This function does not concern any remote controls not programmed to work with the anti-passback function. 
 
Note: The anti-passbacks are reset on each power up. 

   

Switches and LEDs 

 

 

Switches 1, 2 and 3 define the time of the anti-passback function (+ or - 2 minutes):  

S1 

S2 

S3 

Meaning 

OFF 

OFF 

OFF 

No anti-passback handling. 

ON 

OFF 

OFF 

Anti-passback set to 05 minutes. 

OFF 

ON 

OFF 

Anti-passback set to 10 minutes. 

ON 

ON 

OFF 

Anti-passback set to 15 minutes. 

OFF 

OFF 

ON 

Anti-passback set to 30 minutes. 

ON 

OFF 

ON 

Anti-passback set to 45 minutes. 

OFF 

ON 

ON 

Anti-passback set to 60 minutes. 

ON 

ON 

ON 

Permanent anti-passback. 

 

 

Switches 4 and 5 define the operation of the vehicle detection loops :  

S4 

S5 

Meaning 

 OFF 

 OFF 

Normally Closed loop (NC) or no loop installed. 

ON 

ON 

Normally Open loop (NO) 

 

 

Switch no. 6: It must always be set to OFF.  

Any action on this switch resets the rolling and anti-passback codes. 

 

 

Switch No. 7 sets the receiver's relay times:  

S7 

Meaning 

 OFF 

Central unit's time. 

ON 

Time of 0.2 sec. 

 

 

Switch no. 8: Do not use. 

 

 

LED: The LED indicates the operating states as follows: 

State 

Meaning 

Flashing for 1 to 2 sec 

Power up or  
after switching of switch 6: Erasure of anti-passback and rolling code. 

Permanently OFF 

The receiver has no power supply: Check the connection to the receiver's + and - 
terminals. 

Flickering  

The central unit is not connected correctly to the receiver's D + and D- 
terminals. 

Permanently ON 

Correct communication with the central unit: Diagnosis displays "RF". 

Goes off for 1 second 

Correct reception of the RF emission by an INTRATONE 868 MHz remote 
control. 

Intelligent Security & Fire Ltd.

Summary of Contents for EEN-REC2

Page 1: ...and III of the remote control trigger the receiver s EXIT relay Unlock time of the doors The unlock time is set by the central unit switch No 7 can force it to 0 2 seconds pulse Vehicle Detection Activating each ENTRY EXIT relay may depend on the use of vehicle detection loops These loops can be set independently to Normally Closed NC or Normally Open NO using switches nos 4 and 5 of the receiver ...

Page 2: ...s S1 S2 S3 Meaning OFF OFF OFF No anti passback handling ON OFF OFF Anti passback set to 05 minutes OFF ON OFF Anti passback set to 10 minutes ON ON OFF Anti passback set to 15 minutes OFF OFF ON Anti passback set to 30 minutes ON OFF ON Anti passback set to 45 minutes OFF ON ON Anti passback set to 60 minutes ON ON ON Permanent anti passback Switches 4 and 5 define the operation of the vehicle de...

Page 3: ... As near as poss to central CODED AERIAL EEN REC2 RECEIVER Voltage free contact to device to control on entry Voltage free contact to device to control on exit Entrée R T C R T C Sortie P V POWER 2 1 ANT 200 m max 0 50mm or 0 80mm twisted pair C T R C T R A2 BUS D D A1 ALARM S E 2 X 5A 24V entry exit Relays SWITCHES ON 1 2 3 4 5 6 7 8 To detection of entry vehicle To detection of exit vehicle P V ...

Page 4: ...an be connected to any other of the central unit s terminals only the terminal numbers change Once the receiver is correctly connected to the INTRATONE RESIDENTIAL central unit the unit s LED must be permanently on correct communication with the central unit and the central unit must indicate on the diagnostics screen that it has detected the receiver by displaying 1 RF example for terminal No 1 i...

Page 5: ... standard EN 60950 2000 applied EMC standard EN 301 489 3 2000 applied radio standard EN 300 220 3 2000 applied Cabling The cables used to connect the receiver to an INTRATONE RESIDENTIAL central unit must be installed in accordance with the instructions describing the level 2 protected environment of the NF EN 61000 4 4 standard Please follow the recommendations given in the cabling and connectio...

Page 6: ...Page 6 6 installation and user guide for the Intratone EEN REC2 V233 0011 AD receiver Sizes 180 66 143 46 110 116 33 I n t e l l i g e n t S e c u r i t y F i r e L t d ...