Installation and user guide for the EEN-BP2R car park control unit 

Page 5 / 6 

 

V233 – 0008 – AA 

Anti-passback 

 

Anti-passback  controls  the  2  ENTRY  and  EXIT  doors  to  prevent  repeated  attempts  at  accessing 
the  ENTRY  door.  The  resident  must  therefore  have  left  via  the  EXIT  door  before  again  being 
allowed access to the car park via the ENTRY door. 

 

The anti-passback function works by setting an anti-passback time during which any new attempt 
to gain access via the ENTRY door is systematically denied. Access via the ENTRY door will be 
authorised again, either after this time has expired, or once the resident has left via the EXIT door. 

 

The anti-passback function is only activated with the combined use of ENTRY and EXIT vehicle 
detection  loops,  and  it  only  works  with  remote  controls  programmed  to  work  with  the  anti-
passback function (see www.intratone.com).  This function does not concern any remote controls 
not programmed to work with anti-passback. 

 

Anti-passback access conditions are set fully using switches 5, 6 and 7. 

 

On each power up, the anti-passback conditions are cancelled. The current anti-passback waiting 
times may be cancelled at any time by setting the 3 switches 5, 6 and 7 to the OFF position. 

 

Note: The anti-passback functions are also cancelled whenever switches 5, 6 and 7 are switched. 

 

Vehicle detection loops for anti-passback 

 

Switch 4 

Vehicle detection loop 

OFF 

Normally Closed or no loop fitted. 

ON 

Normally Open or with a loop fitted. 

 

Anti-passback times 

 

Switch 7  Switch 6  Switch 5  Anti-passback times 

OFF 

OFF 

OFF 

No anti-passback handling. 

OFF 

OFF 

ON 

Anti-passback time set to5 minutes. 

OFF 

ON 

OFF 

Anti-passback time set to10 minutes. 

OFF 

ON 

ON 

Anti-passback time set to15 minutes. 

ON 

OFF 

OFF 

Anti-passback time set to30 minutes. 

ON 

OFF 

ON 

Anti-passback time set to45 minutes. 

ON 

ON 

OFF 

Anti-passback time set to60 minutes. 

ON 

ON 

ON 

Permanent anti-passback  
(Obligation to leave before being able to enter again). 

Note: anti-passback times are indicative and may vary by +/- 1 minute. 

 

Summary of Contents for EEN-BP2R

Page 1: ... can be installed on a DIN rail or wall mounted Car park control unit features 12 24 V AC DC 200 mA 2 2A 24V relays Remote control management On the internet www intratone com Read write mode from the web Max 2 500 remote controls Opening of max 5 units per remote control Be sure to note the unit s serial number It will be needed for managing your remote controls from the Internet Description of t...

Page 2: ... be no metal obstacles between the active antenna and the normal position used for operating the remote controls It is therefore preferable to fit the active antenna in a high location to avoid obstacles e g wire netting If you are unable to position the active antenna where it will ensure normal operation on entry and exit of the car park a second antenna may be added ref EEN ACOD thus providing ...

Page 3: ...the www intratone com website using your login and password or by opening an account create an account button Create a residence then a car park control unit access type by entering the unit s serial number Then program the remote controls that you will distribute to the residents They will automatically open the accesses controlled by the control unit The first of them will activate the control u...

Page 4: ... position button I for the ENTRY relay and button II for the EXIT relay if the remote control is authorised for this car park control unit Switch 8 in the ON position button III for the ENTRY relay and button IIII for the EXIT relay if the remote control is authorised for this car park control unit Setting of the door unlock time Switch 3 Switch 2 Switch 1 Unlock time of the ENTRY and EXIT relays ...

Page 5: ...e controls not programmed to work with anti passback Anti passback access conditions are set fully using switches 5 6 and 7 On each power up the anti passback conditions are cancelled The current anti passback waiting times may be cancelled at any time by setting the 3 switches 5 6 and 7 to the OFF position Note The anti passback functions are also cancelled whenever switches 5 6 and 7 are switche...

Page 6: ...Installation and user guide for the EEN BP2R car park control unit Page 6 6 V233 0008 AA Sizes ...

Reviews: