3.1.5 Fixing the boundary temperature level of the outlet boiler water 

The  emergency  opening  of  the  servo-valve  during  exceeding  of  the  boundary 

temperature level of the boiler can be easily checked during boiler start-up. It can be carried 
out  when  the  mixed  valve  is  not  open  yet,  the  working  thermostat  at  a  first  burner  stage  is 
fixed  at  its maximum  level  and  the  settled  boundary  level  of  the  outlet  boiler  water  is  at  its 
minimal level.  Mostly the boiler behavior is that if the working thermostat is switched off the 
boiler  temperature  keeps  increasing  in  case  the  heating  water  would  not  be  leaded  (for 
example that could be happen at a closed mixed valve). When the boundary temperature level 
of the heating water is reached the light indication 7 appears (see Figure 3a), the boiler must 
be  stopped,  the  mixed  valve  must  be  opened  and  the  circulation  pumps  P1  and  P2  must 
operate,  it  is  possible  to  start  operation  of  the  circulation  pump  in  the  domestic  hot  water 
circuit in case the water tank temperature is less than 90

0

C. The boundary emergency boiler 

water  temperature  can  be  adjusted  from  menu 

SETTINGS”  ->  „Set  limit  Tk”

  in  the  range  of 

(+90 

0

C)  –  (+105 

0

C). 

The  setting  is  to  be  done  in  a  way  that  after  activating  the  first 

stage, the boiler would not be stopped by the working thermostat, neither to be able to 
reach  the  assigned  boundary  level  of  the  outlet  boiler  temperature.  That  means  the 
lowest  possible  temperature  setting  is  of  the  1

st

  stage  of  the  working  thermostat  (for 

e80

0

C), the fixed emergency boiler temperature  is higher (for e95

0

C) 

and the emergency thermostat has the most possible settings (for in105

0

C). The 

boiler emergency thermostat is an automatic discharger of hot water during overheating 
of the boiler and operates together with an automatic filling valve with  a cold water of 
the water-conduit.

 

If  the  boiler  temperature  of  the  outlet  boiler  water  drops  bellow  the  fixed  boundary 

temperature level, the indication 7 stops and the Controller goes independently into the settled 
operation mode with a control of the servo-valve. 

Figure 8 shows the adjusting of the outlet emergency water temperature of the boiler 

at: 

a)

 

High temperature level 

Tp

b)

 

Correct temperature level 

Tp

,  

 
 
 
 
 
 
 
 
 
 
 
where: 
Tn is a temperature of the emergency boiler thermostat 
Tb is a boiler temperature (in our case an emergency one) 
Tp is a temperature of 1

st

 stage of the working thermostat  

 

3.1.6 Adjusting the assignation of the working thermostats for 1

st

 and 2

nd

 burner stage 

About 1

st

 stage

 – from menu 

„SETTINGS” -> „Thermostat st1” 

is to be fixed an operation 

temperature of 1

st

 stage within

 

75 - 90  С; 

Emergency boiler stopping 

CONTROLLER safety 

function 

Without installed 

controller 

Тn 
Тb 
Тр 

Тn 
Тb 

Тр 

Т 

t[min] 

Т 

t[min] 

a) 

b) 

Figure 8 

Summary of Contents for Dynamic Boiler Controller

Page 1: ...t 00359 898 606 796 f 00359 596 325 80 info intiel com www intiel com 9 Peter Beron Str Pomorie 8000 Bulgaria 1 INTIEL THE ELECTRONICS ON YOUR SIDE Dynamic Boiler Controller User s Manual...

Page 2: ...r which is being managed by the domestic hot water thermostat installed in the water heater or in the accumulating reservoir where also can be added a timer switch The Controller provides the heating...

Page 3: ...tat or the sensor after the mixed valve O does not send a command for a start in a period adjusted by the customer of 12 24 36 or 48 hours after the last command is being sent 1 1 15 The main distingu...

Page 4: ...best results can be achieved by using proportional thermostat with an integration control of the temperature The precision class of the used room thermostat directly affects to the precision in keepi...

Page 5: ...low heating water temperature bellow 5 and fuel presence the boiler and pumps are being switched on as the valve starts opening in order to prevent freezing light indication 8 is being activated figur...

Page 6: ...dication for return temperature water decreasing bellow the assigned value 7 Control indication showing exceeded emergency outlet boiler temperature 8 Control indication showing very low heating water...

Page 7: ...ch the heating water temperature has a maximum value Tou min see point 1 5 5 1 With temperatures below 20 and above 120 instead of values are being indicated low and hi To enter the main menu button S...

Page 8: ...e settings restore the default settings Test actuator it is being used for a control of correct wiring connection of the actuator Press SET button in order to make some changes By means of button it i...

Page 9: ...oiler outlet temperature exceeds the assigned one the Controller indicator 7 Figure 3a will light the boiler will stop by force the mixed valve will be open and the circulation pumps P1 and P2 will st...

Page 10: ...e can be constant or it can be defined in relation to the outdoor temperature Thus there is no cooling of the radiators during penetrating of a cold air through the windows towards the floor If such f...

Page 11: ...assigned one The previous mentioned could happen if the outlet boiler temperature reaches its emergency value and the Controller has been opened the mixed valve 1 5 5 1 Selection of the lower border o...

Page 12: ...0 2 Installation of the Controller 2 1 Introduction The installation of the Controller must be done by a qualified staff The connection of the boiler the mixed valve servo actuator and the circulation...

Page 13: ...sor of the return boiler water V together with the sensor of the outlet water temperature K and in the same time setting up the minimal temperature of the return water at 650 C In this way the outlet...

Page 14: ...h its resistance that can reach 100 The room thermostat location is something very important It is suitable the thermostat to be placed at the most occupied room in the house that will become a standa...

Page 15: ...domestic hot water circuit are shown at Figure 7 a With four way mixed valve and third circulation pump for domestic hot water circuit Figure 7a b With four way mixed valve and three way magnet valve...

Page 16: ...the domestic hot water timer is being switched on by time while the premises heating is being provided opned mixed valve so the Controller will send a signal for a complete mixed valve closing in ord...

Page 17: ...lower than 60 the boiler fan operates constantly and it is managed by means of the room or outdoor thermostat During smooth increasing of the boiler temperature above 60 for example when the valve is...

Page 18: ...terminals X16 This contact is being opened in case of boiler overheating If an emergency thermostat is not provided so terminals X16 are to be connected in a short circuit by means of outer electrical...

Page 19: ...tion 6 appears and the servo actuator starts closing the boiler water flow to the heating circuit The recommended levels of the fixed return boiler water temperature are as follows Boilers with steel...

Page 20: ...er activating the first stage the boiler would not be stopped by the working thermostat neither to be able to reach the assigned boundary level of the outlet boiler temperature That means the lowest p...

Page 21: ...use Regarding faster actuators it is to be fixed less operation time and vice versa The default setting is 20 3 1 8 Control of the domestic hot water thermostat operation If no one of the indications...

Page 22: ...rcuit in the sensor or temperature bellow 300 C The sensor is to be replaced The premises cannot be heated to the desired temperature Low temperature of the boiler water Increase the assignation of th...

Page 23: ...inary adjusted with most of the room thermostats For example it can be a not freezing temperature that is adjusted to most of the room thermostats Then to go back to winter mode is enough to get back...

Page 24: ...water tank temperature 30 80 60 Thermost at st1 Operation thermostat assignation of 1st burner stage 75 90 85 Thermost at st2 Operation thermostat assignation of 2nd burner stage 60 75 65 Outdoor temp...

Page 25: ...nths after the production date The warranty is extended to the malfunctions that occur during the warranty period and are result of the production reasons or defective used parts The warranty does not...

Reviews: