Table 1
P A R A M E T E R
Indication
Description
Range
Default
settings
User
settings
dt
Set temperature difference
between the solar panels and
the boiler -
∆T
2 ÷ 20 °С
10 °С
tbS
Set temperature in the boiler
to which it can normally be
heated by the solar panels.
Tb
set
10 ÷ 80 °С
60 °С
Minimum temperature in the
boiler below which the
defrosting of the panels
stops.
Тbmin
not set
20 °С
tbH
Maximum allowable
temperature in the boiler.
Tbmax
80 ÷ 100 °С
95 °С
tPL
Minimum temperature of
solar panels.
Трmin
20 ÷ 50 °С
40 °С
tPH
Maximum allowable
temperature of solar panels.
Трmax
80 ÷ 110 °С
105 °С
tPd
Temperature at which solar
panels are allowed to
defrost.
Тpdef
-20 ÷ 10 °С
OFF
ttc
Cooling delay time to set
temperature.
0 ÷ 5 h.
4 h.
Tb correct
Correction of the indication
temperature
Tb
-10 ÷ 10 °С
0 °С
Tp correct
Correction of the indication
temperature
Tp
-10 ÷ 10 °С
0 °С