SET UP (continued)

Inflation

Inflate the Spa Tub Wall

1.

 

Take out the ground cloth 

(19)

 and spread it over the cleared area. Then spread out the spa liner over 

the ground cloth and point the drain valve towards a suitable draining area.

 

NOTE:

 Spread the ground cloth with the bubbles facing down over the cleared area where you intend 

 

to setup your spa.

2. 

Flip up the control base side cover

 (4) 

to reveal the air blower inflation outlet. Pull out the latch to open 

the cover, insert the hose adaptor

 (24)

 with hose

 

and reattach the latch to the hose adaptor to secure it 

in place 

(see drawing 2)

.

2

1

2

3

4

5

3

7

1

2

4

3. 

Unscrew the air valve cap on the spa tub to reveal the stem in the 

up position for inflation. Insert the other end of the inflation hose 

(7)

 

into the valve and turn to the right to lock it in position

 (see 

 

drawing 3)

.

4.

  Press the   button to turn on the control panel buttons first. Press 

the 

 button to inflate the spa tub wall for 8 to 10 minutes until it 

is firm to the touch but not hard 

(see drawings 4 & 5)

.

 

IMPORTANT:

 Do not over inflate or use high pressure air 

compressor to inflate.

Summary of Contents for PureSpa SB-H10

Page 1: ...dates to the instruction manual without notice For illustrative purposes only IMPORTANT SAFETY RULES Please read understand and follow all instructions carefully before installing and using this produ...

Page 2: ...stalled and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation...

Page 3: ...rovided for this purpose Risk of Electric Shock Do not permit any electric appliance such as a light telephone radio or television within 5 feet 1 5 m of a spa or hot tub Risk of Electric Shock Do not...

Page 4: ...e standing in water or when your hands are wet Do not leave the spa empty for extended period of time Do not expose the spa to direct sunlight for extended period of time Provide adequate drainage sys...

Page 5: ...pa fittings For multiple outlet use only Wall mounting only Replace suction fittings within 3 installed year Tool required screwdriver Spa suction fitting maximum flow rate 8 5 gpm 510 gph Check sucti...

Page 6: ...995 11995 11995 11995 11995 11 SUCTION FITTING 3 11695 11695 11695 11695 11695 12 FILTER CARTRIDGE HOUSING 2 11798 11798 11798 11798 11798 13 FILTER CARTRIDGE 2 11692 11692 11692 11692 11692 14 FILTER...

Page 7: ...tric shock experienced should be investigated by a qualified electrician prior to use of the spa Unplug the spa until the cause is determined and any corrective action completed Site preparation and r...

Page 8: ...ward while pushing the control panel down see drawing 1 2 Humidity is a natural side effect of indoor spa installation The room shall be properly ventilated to allow moisture to escape Install a venti...

Page 9: ...veal the air blower inflation outlet Pull out the latch to open the cover insert the hose adaptor 24 with hose and reattach the latch to the hose adaptor to secure it in place see drawing 2 2 1 2 3 4...

Page 10: ...er 1 Open the inflation valve and insert the inflation hose 7 into the valve press to inflate until it is firm to the touch but not hard see drawing 7 2 Disconnect the inflation hose 7 from the air bl...

Page 11: ...ure release valve kicks in and releases excess air Inflation of spa in the morning IMPORTANT Deflation For Spa Tub Wall 1 Unscrew the cap to reveal the stem push the stem in and turn 90 degree right t...

Page 12: ...es and any other spa cleaning attachment from the spa outlets before spa usage see drawing 11 Re attach them after usage for water filtration and cleaning 4 Before filling with water ensure the bottom...

Page 13: ...water The spa is not properly covered with the spa cover when the water is heating Celsius Fahrenheit Toggle button The temperature can be displayed in either Fahrenheit or Celsius The system s defau...

Page 14: ...ture above 41 F 5 C then press the button to heat up the water to the desired temperature If problem persists contact Intex Service center E95 Water temperature too high Turn off and unplug the contro...

Page 15: ...spa water every 2 3 months or it becomes cloudy and proper water chemistry does not clear it up See Spa Tub Drainage and Spa Tub Cleaning sections for details 3 Use spa chemicals to maintain proper w...

Page 16: ...Result if too high Scale formation cloudy water shorter filter heater runs eye skin irritation high chlorine demand Calcium Hardness CaCO3 refers to the amount of calcium and magnesium dissolved in t...

Page 17: ...d sodium bisulfate or muriatic acid to the water drop by drop until the test strip indicates a 240 ppm reading then add 0 528 Lb 238 g of sodium bisulfate or 0 202 qt 192 ml of muriatic acid NOTE Afte...

Page 18: ...ll chemicals with care and wear extra personnel protective equipment including goggle and gloves It is very important not to splash acid onto your skin or clothing or into your eyes Lowering pH Loweri...

Page 19: ...ng out Spa Tub Cleaning If dirt is visible in the water or water becomes cloudy and proper water chemistry does not clear it up change the water and clean the spa tub See Spa Tub Drainage section on h...

Page 20: ...in the sun for an hour before folding 5 Fold the spa tub loosely and avoid any sharp corners to prevent damage or leakage to the spa tub liner 6 Prepare additional new cartridges for next time use 7...

Page 21: ...p is too hot Turn off and unplug the spa Let it cool down and restart all over again If problem persists contact Intex Service Center Filtration pump NOT WORKING Dirty filter cartridge Filtration inle...

Page 22: ...y Control base components not securely attached Control base ground not level and firm Spa filter motor failed Ensure control panel back cover and all inlet outlet are securely connected Ensure ground...

Page 23: ...ly follow below steps to disassemble it IMPORTANT You must drain out any remaining water inside the piping system of the control base before replacing any parts Tools required One adjustable wrench an...

Page 24: ...pute settlement board and unless and until the provisions of these paragraphs are carried forth no civil action may be instituted The methods and procedures of this settlement board shall be subject t...