background image

307

IO

(307IO)  MODEL HP3220  HEAT PUMP  ENGLISH  7.5” X 10.3”  PANTONE 295U  10/10/2017

English

OWNER’S MANUAL

Heat Pump

Model HP3220
220-240 V~, 50 Hz

IMPORTANT 

SAFETY RULES

Read, Understand, and Follow 

all Instructions Carefully before

Installing and using this Product.

Don’t forget to try these other fine Intex products: Pools, Pool 
Accessories, Inflatable Pools and In-Home Toys, Airbeds and 
Boats available at fine retailers or visit our website.
Due to a policy of continuous product improvement, Intex 
reserves the right to change specifications and appearance, 
which may result in updates to the instruction manual without 
notice.

©2017 Intex Marketing Ltd. - Intex Development Co. Ltd. - Intex Trading Ltd.
- Intex Recreation Corp.
All rights reserved/Tous droits réservés/Todos los derechos reservados/Alle 

Rechte vorbehalten. Printed in China/Imprimé en Chine/Impreso en China/Gedruckt in China.

®™ Trademarks used in some countries of the world under license from/®™ Marques utilisées dans certains pays sous 
licence de/Marcas registradas utilizadas en algunos países del mundo bajo licencia de/Warenzeichen verwendet in einigen 
Ländern der Welt in Lizenz von/

Intex Marketing Ltd. to/à/a/an Intex Trading Ltd., Intex Development Co. Ltd., G.P.O 

Box 28829, Hong Kong & Intex Recreation Corp., P.O. Box 1440, Long Beach, CA 90801

 • Distributed in the European 

Union by/Distribué dans l’Union Européenne par/Distribuido en la unión Europea por/Vertrieb in der Europäischen Union 
durch/

Intex Trading B.V.,  Venneveld 9, 4705 RR Roosendaal – The Netherlands

www.intexcorp.com

307-*IO-R0-1810

For illustrative purposes only.

Summary of Contents for HP3220

Page 1: ...g Ltd Intex Recreation Corp All rights reserved Tous droits r serv s Todos los derechos reservados Alle Rechte vorbehalten Printed in China Imprim en Chine Impreso en China Gedruckt in China Trademark...

Page 2: ...NSTRUCTIONS English Page 2 Warnings 3 4 Parts Reference 5 Product Specifications 6 Set Up Instructions 7 11 Display Control Panel Operation 12 13 Maintenance 14 Pool Water Chemistry 14 Heat Pump Carin...

Page 3: ...disassembly by adults only Do not attempt to plug in or unplug this product while standing in water or when your hands are wet Position this product away from pool to prevent a child from climbing on...

Page 4: ...y have been given supervision or instruction concerning use of the heat pump by a person responsible for their safety The heat pump doesn t work at air temperatures below 8 C Disconnect the power cabl...

Page 5: ...or illustration purpose only Actual product may vary Not to scale When ordering parts be sure to quote the model number and part numbers REF NO DESCRIPTION QTY SPARE PART NO 1 L SHAPE O RING 2 11228 2...

Page 6: ...Performance COP 4 1 General Data Voltage Frequency Phase 220 240 V 50 Hz with in line RCD 1 PH Rated current 3 5 A Advised fuse 16 A Recommended pool water capacity 5 11 m Required system water flow r...

Page 7: ...collection containers The heat pump must be fixed and installed on a flat solid vibration free and level support cement slab or prefabricated platform Do not install the heat pump on unstable ground T...

Page 8: ...event chemical saturated water reflux which could damage the heat pump and void the warranty The water circulation system must be arranged observing the following general layout Pool Pump Filter Heat...

Page 9: ...Typical in ground pool arrangement Pool Filter Pump Chemical Treatment Heat Pump Power Cable Inlet Condensation Draining Pipe Water to Pool Water Pump Filter Check Valve Chemical Treatment Water from...

Page 10: ...electrical outlet socket Initial Operation Make sure the pool is filled with water to the correct level the skimmer and suction fittings are below the water level To heat the pool water the filter pu...

Page 11: ...s higher than 1m above or below the heat pump s automatic flow switch adjustment knob your specialist technician may need to adjust the initial startup water flow rate Refrigerant Gas Pressure Verific...

Page 12: ...its will flash Press or to adjust the hour from 00 to 23 2 Press again and the minute MM digits will flash Press or to adjust the minute from 00 to 59 3 Press again to confirm the Clock Time Timer ON...

Page 13: ...same time for 5 seconds The LED display will show a lock icon The button is also locked To unlock press and at the same time for 5 seconds and the lock icon will disappear Mode Setting Button For qual...

Page 14: ...le from the main electrical outlet Or turn off the electrical power at the main circuit breaker panel 2 Shut off the water supply bypass kit to the heat pump 3 Disconnect the IN and OUT water connecti...

Page 15: ...ne level every 2 3 days Verify pH level once a week Verify Alkalinity level every 3 4 weeks More often if you own an Automatic Chlorine or Bromine Feeder Verify Calcium Hardness once a month Above tes...

Page 16: ...gas pressure lower Compressor failure Probable accumulation of condensation Possible water leak from the water exchanger or from hydraulic unit connection devices Follow the instructions in Initial O...

Page 17: ...atus means the unit is electrically connected but not running Setting Step 1 Standby status Press M 5 seconds Press M again 1 27 Press to enter heating temperature setting press or to alter heating te...

Page 18: ...f 0 1 1 Adjustable by technicians 08 Mode cooling only heat pump auxiliary electrical heating hot water 0 3 3 hot water Adjustable by technicians 09 Water pump keep running or stop after compressor st...

Page 19: ...ature sensor connection T5 temperature sensor broken replace T5 sensor Terminal block for T5 connection on PCB broken replace PCB Water out temperature sensor broken Check T4 temperature sensor connec...

Page 20: ...nnection on PCB broken replace PCB No water flow or low water flow Verify if water inlet and outlet hoses pipes are connected correctly Ensure pool inlet and outlet cover grid is clean and free from o...

Page 21: ...s the necessary competence in emission prevention recovery of fluorinated greenhouse gases and safe handling of the relevant type and size of equipment covered by the certificate Record keeping Operat...

Page 22: ...DEL HP3220 HEAT PUMP ENGLISH 7 5 X 10 3 PANTONE 295U 10 10 2017 English 307 IO SAVE THESE INSTRUCTIONS English Page 22 SERVICE BY QUALIFIED TECHNICIANS continued Parts Diagram for qualified technician...

Page 23: ...ANCE 22 HIGH PRESSURE PROTECTION SWITCH 6 TRANSFORMER 23 LOW PRESSURE PROTECTION SWITCH 7 FIVE POSITION TERMINAL BLOCK 24 SUCTION VALVE 8 CLIP 25 PIPE EXCHANGER TO CAPILLARY 9 ELECTRIC BOX 26 LOGO 10...

Page 24: ...ermine the validity of the claim If the item is covered by the provisions of the warranty the item will be repaired or replaced with the same or comparable item at Intex s choice at no charge to you O...

Reviews: