Page 34
Functional Error
Air Blower Problems
Issues with the air can be due to a defective air pump, bad tub, and damaged or missing seals.
Problems with the air pump could also be due to it becoming overheated.
If the Air Blower has failed and no longer turns on:
Verify that the connections for the terminals are not swapped. For example, a Terminal that
should be connected to #7 is connected to #9. Testing the air pump’s voltage on the PCB next.
Terminals (7&8) should be tested with a voltmeter for voltage reading equal the wall voltage. Do
this by putting probes to the two terminals and run the air blower function on the spa.
If the reading on the terminals is ok, change the air blower.
If the reading is on the terminals is not ok, change the PCB
To change the air blower, first access the inside of the Control Base. Release terminals of 7&8
and the wire leading from the air blower to the grounding box. Release the screws that hold the
blower.
Yes
No Bubble
No
1. Replace a bubble motor;
2. Or replace a PCB
Go Back to Next Step
END
Run Bubble,
bubble come out?