27
7.3.1 Automatic mode (Switching position I )
Automatic mode is the normal operating mode, and is selected by
Switch position I.
In this mode, the unit automatically switches from rainwater to
mains water if the float switch detects the rainwater tank is empty.
Two operating modes can be used according to the two positions
of the float switch, both of which are indicated by the display of the
motorized valve (see chapter 5.4).
Rainwater mode:
Rainwater tank is full
(Float switch remains floating upright in the tank)
Mains water mode:
Rainwater Tank is empty
(Float switch hangs vertically towards tank bottom)
7.3.2 Maintenance mode (Switch position II )
The maintenance mode is selected by
Switch position II
. This
mode is selected only when maintenance is to be performed in
the tank. The RM Favorit then operates in continuous mains water
mode, independent of the float switch.