Safety first

The RAINMASTER Eco pump, controller and float switch are run from a 24 V 
low   voltage   supply   for   added   safety.   This   low   voltage   is   obtained   via   a  
switchable power supply, which can be used on 110-230 volt throughout the 
world.   The   switchable   power   supply   has   all   the   necessary   internationally  
recognized test certificates. This means, maximum safety during installation 
and use of the rainwater system and tank.

Alternatively, the RAINMASTER Eco can also be run directly off  a DC supply, 
such as a 24 V battery system from a photovoltaic system.

 

 

The DVGW-certified RAINMASTER ECO features the required “air gap”. The 
so-called  “air  gaps  AA  and  AB ”  are  the  only  ones  approved  for  supply  of  
back-up mains water during water shortages, as per the European standard 
EN1717.  Regulations  state  that  mains  water  and  processed  water  should  
never come in contact with each other for reasons of hygiene. In this sense, 
the RAINMASTER ECO fulfills the world’s highest safety standards.

 

Mains water top up with “air gap AB”, regarding EN1717

 

1: Mains water inflow 3: Maximum water level
2: Overflow opening 4: Air gap

Summary of Contents for RAINMASTER Eco

Page 1: ...ngle family dwellings undergoing renovation The most important examples of system configurations can be found here Rainwater harvesting with the RAINMASTER Eco and an underground tank You can even ins...

Page 2: ...en designed to be backflow proof 1 RAINMASTER Eco Rainwater system7 Emergency overflow 2 Mains water connection 8 PURAIN Rainwater filter 3 Pressure line set with expansion tank 9 Floating suction fil...

Page 3: ...r systems or other water systems 1 RAINMASTER Eco Rainwater system6 Suction line carrying processed greywater 2 Mains water connection 7 Emergency overflow 3 Pressure line set with expansion tank 8 Gr...

Page 4: ...Eco can also be run directly off a DC supply such as a 24 V battery system from a photovoltaic system The DVGW certified RAINMASTER ECO features the required air gap The so called air gaps AA and AB...

Page 5: ...ressure 3 5 bar Max Volume flow rate RM Eco 10 RM Eco 1410 l min 14 l min Intake level self priming See intake diagram Pump start up pressure approx 2 2 bar Protion rating IP 44 Noise level RM Eco 10...

Page 6: ...Design with dimensions and components...

Page 7: ...ond floor Pressure side dimensions In the case of a single family dwelling a limited number of consumers would be drawing on the rainwater system at any one time This means that the RAINMASTER Eco pro...

Page 8: ...f up to 2bar 500 l h RM Eco 10 or 2bar 700 l h RM Eco 14 A high pressure cleaner with a flow rate of up to 500 l h RM Eco 10 or up to 800 l h RM Eco 14 Note The RAINMASTER Eco is not suitable to be in...

Page 9: ...l be necessary to ensure the intake process proceeds reliably and with sufficient safety Note The charging pump boosts the water intakepressure so that an intake level of up to 3 m high can be attaine...

Reviews: