27
10.2 Cleaning solution
We recommend the cleaning solution be made from regular domestic cleaning agents and should be
mixed as follows:
1)
Acid cleaning against deposits such as calcium carbonate
Citric acid: Available in all drug stores as granulate packets
Dissolve 200 g per cartridge in 2 l warm, clean water (30°C) .
2)
Alkali cleaning against excessive Biofouling
Domestic cleaner with chlorine base (such as Bref-Henkel, DanKlorix):
Available in all drug stores as liquid concentrate (0.5% Chlorine portion).
Dilute 0.5 l per cartridge in 2 l warm, clean water (30°C).
ATTENTION!
Never mix acids and alkali!
All pipes and connections must be rinsed well with water after being cleaned with
acid before cleaning with alkali and the other way around!
Follow the warning and safety instructions of the chemicals used!
Protective gloves and glasses are to be used during all cleaning operations!
11. Spare parts
Article description
Drawing no.
(s. chap. 4)
Order description
AQUALOOP controller
[9]
ALMS-CU
AQUALOOP AC switching power supply 24 V
DC, 4A
[7] ALMS-PSS-4A
AQUALOOP Float switch 15 m
[10]
ALMS-FS15m
AQUALOOP Double pumping unit
[2]
ALMS-P
12. Optional accessory
Order description: AL-PCS
AQUALOOP Pressure sensor for monitoring pump performance
Measuring range:
-0.8 to +0.8 bar,
Connection:
4-20 mA, ventilated 3 line terminals
Cable:
Ø6mm, 3 m length