Interfaz SM-RC-MBS-1                      

FW:0.3

 

 

Interface SM-RC-MBS-1

                        

FW:0.3 

                                

                  1 / 2

 

© Intesis Software S.L.U. - Todos los derechos reservados/ All rights reserved  

 

IntesisBox es una marca registrada de / is a registred trademark of

 

Intesis Software SLU

 

 

La información en este documento puede variar sin previo aviso. / This information is subject to change without notice.

 

 

Doc. Rev.1.2 

 

URL 

email 

Phone 

 

http://www.intesisbox.com                                          
[email protected] 
+34 938047134 
 

 

 
 
 

 
 
 

 
 

 
 
 

 
 

 

 
 

 

 
 

 
 
 

 
 
 

 
 
 

 

 

 
 
 

 
 

 

 
 
 

 
 
 

 
 

 
 
 

 
 
 

 
 
 

 

 

 

 

Esta  interfaz  debe  ser  instalada  por  personal  técnico 

acreditado  (electricista,  instalador  o  personal  técnico 

cualificado)  y  siguiendo  todas  las  instrucciones  de 
seguridad. 

 

La interfaz debe ser instalada en una ubicación con acceso 
restringido. 

 

Antes  de  manipular  en  el  interior  del  A.A.,  asegúrese  de 
que está completamente desconectado de la red eléctrica.  

 

En caso de instalación mural de la interfaz junto a la unidad 
interior  de  A.A.,  fije la  interfaz  de  forma  segura  siguiendo 

las instrucciones del diagrama de abajo. 

 

En  caso  de  instalación  de  la  interfaz  en  el  interior  de  la 

unidad  interior  de  A.A.,  fije  la  interfaz  y  los  cables  de 

comunicación preferiblemente en algún punto de la carcasa 
de plástico de forma que no interfieran al libre movimiento 

de  partes  móviles  y  alejados  al  máximo  de  tubos 
conductores de líquidos y cables eléctricos. 

 

 

 

 

This  interface  must  be  installed  by  accredited  technical 

personnel  (electrician,  installer  or  qualified  technical 

personnel) and they must follow all the safety instructions. 
 

 

This  interface  must  be  installed  in  an  acces  restricted 
location. 

 

Before  manipulating  the  AC  indoor  unit,  make  sure  it  is 
completely disconnected from Mains Power. 

 

In  case  of  wall  mounting  of  the  interface  next  to  the  AC 
indoor  unit,  attach  the  interface  safely  following  the 

instructions of the diagram below. 

 

In  case  of  installation  of  the  interface  inside  the  AC  indoor 

unit,  attach  the  interface  and  communication  cables 

preferably  to  any  proper  point  of  the  plastic  cover  of  each 
unit  and  take  care  to  not  block  free  movement  of  mobile 

parts. Locate  them as far as possible from pipes containing 
liquids and power cables. 

 

 

Desconecte el aire acondicionado de la red eléctrica. 

 

Fije la interfaz a la pared junto a la unidad interior del aire 
acondicionado  siguiendo  las  instrucciones  del  diagrama  de 

abajo o dentro de la unidad interior del aire acondicionado 
(respete las instrucciones de seguridad anteriores). 

 

Conecte  la  interfaz  al  bus  F3F4  en  cualquier  punto  del 
mismo. El bus F3F4 es el bus que conecta la unidad interior 

de  aire  acondicionado  y  el  mando  por  cable,  es  un  par  de 

hilos  que  se  conectan  los  terminales  F3F4,  este  bus  tiene 
polaridad. 

 

Conecte  la  interfaz  al  bus  V1V2  en  cualquier  punto  del 
mismo con un par de hilos. 

 

Conecte  el  bus  EIA-485  al  conector 

EIA485

  de  la  interfaz. 

Respete la polaridad. 

 

Tape  la  unidad  interior  del  aire  acondicionado  y  vuelva  a 
conectarla a la red eléctrica. 

 

Siga las instrucciones del Manual de Usuario. 

 

Siga  las  instrucciones  de  la  página  siguiente  para 
configurar la interfaz a través de los micro interruptores. 

 

Disconnect the air conditioning from the Mains Power. 

 

Attach  the  interface  next  to  the  AC  indoor  unit  (wall 

mounting) following the instructions of the diagram below or 
install  it  inside  the  AC  indoor  unit  (respect  the  safety 

instructions given above). 

 

Connect  the  interface  to  F3F4  bus  in  any  point  of  the  bus. 

The  F3F4  bus  is  the  bus  that  connects  the  AC  indoor  unit 

and  the  wired  remote  controller,  is  a  two-wire  bus 
connecting terminals F3F4 of both, this F3F4 connection has 

specific polarity. 

 

Connect  the  interface  to  V1V2  bus  in  any  point  of  the  bus 

using a two-wire cable. 

 

Connect  the  EIA-485  bus  to  the  connector 

EIA485

  of  the 

interface. 

 

Close the AC indoor unit and reconnect it to Mains Power. 

 

Follow  the  instructions  on  the  User

’s  M

anual  to  configure 

and commission the interface. 

 

Follow  the  instructions  of  the  next  page  to  configure  the 
interface through on-board DIP-switches. 

  

WARNING 

  

ATENCIÓN 

Siga  atentamente  estas  instrucciones  de  seguridad  e 

instalación.  Un  manejo  inadecuado  puede  ocasionar  daños 
graves  para  su  salud  y  daños  irreparables  en  la  interfaz  y/o 

en la unidad interior del aire acondicionado. 

Follow  carefully  this  safety  and  installation  instructions.  Not 

proper work may lead to a serious damage for your health and 
may harm seriously the interface and/or the AC indoor unit. 

IMPORTANTE:

 

La máxima distancia entre el SM-RC-MBS-1 y los 

terminales F3F4 V1V2 es de  100 metros (328.08 pies). Consulte 

el manual del aire acondicionado para más detalles. 

NOTA:

 

En algunas unidades interiores no existe el conector F3F4 

y  en  su  lugar  existen  dos  cables  para  la  conexión  del  Control 
remoto. Utilice dichos cables para conectar el bus F3F4. Consulte 

el Manual de Usuario de su unidad interior para más información. 

IMPORTANTE

:  Si  se  conecta  el  mando  del  fabricante  al  mismo 

bus, la comunicación puede perderse. 

 

IMPORTANT:

 

The maximum distance between SM-RC-MBS-1 and 

terminals F3F4 V1V2 is 100 meters (328.08 ft). Check the manual 

of the AC indoor unit for more details. 

NOTE:

 

In some indoor unit models, the F3F4 bus is not available. 

In  its  place,  there  is  a  pair  of  cables  to  connect  the  Remote 
Controller. Use these cables to connect  the F3F4 bus. Check your 

indoor unit’s User 

Manual for more information. 

IMPORTANT

: If a wired remote controller of the AC manufacturer 

is connected in the same bus, communication may shut down. 

 

El Manual de Usuario está disponible en: 

 

https://www.intesisbox.com/en/samsung-modbus-vrf-no-nasa-sm-rc-mbs-1/gateway/ 

 

The 

User’s Manual

 is available at:  

 

 

https://www.intesisbox.com/en/samsung-modbus-vrf-no-nasa-sm-rc-mbs-1/gateway/ 

 

Instrucciones de seguridad 

 

Safety intructions 

 

Instrucciones de instalación 

 

Installation instructions 

 

90 mm / 3.5”

 

IntesisBox

®

 

SM-RC-MBS-1 

MODBUS RTU 

EIA-485 

Bus

 

EIA485 

 A+  B- 

   F3 F4   V1 V2 

  AC Unit    Power 

53 mm / 2.1”

 

Para fijación mural 

extraiga hacia fuera 
las grapas superior 

e inferior hasta oir 

el "click". 
 

For wall mounting 

extract the upper 
and down staples 

until you hear the 

"click".

 

F3F4  V1V2 

Unidad interior de A.A. 

AC Indoor Unit 

(No es obligatorio tenerlo en la red) 

(It is not mandatory to have it in the network) 

 

Conexión al bus F3F4 V1V2. 

Cable de cuatro hilos. 

 

Connection to F3F4 V1V2 bus. 
Four wire cable. 

Remote Controller / Control Remoto 

Samsung 

F3  
F4 

V1  
V2 

Internal  

Electronic 
control board 

 

Tarjeta de  
Control electronico 

Max. 100 m / 328.08 ft 