IntesisBox DK-RC-WMP-1
Installation Manual
Doc. Rev.1.0
La información en este documento puede variar sin previo aviso.
URL
tel
http://www.intesisbox.com
[email protected]
+34 938047134
This information is subject to change without notice.
© Intesis Software S.L. - Todos los derechos reservados/ All rights reserved
IntesisBox es una marca registrada de / is a registred trademark of
Intesis Software SL
WARNING
Follow carefully this safety and installation instructions. Improper work may lead to serious harmful for your health and also may
damage seriously the interface and/or the AC indoor unit.
• This interface must be installed by accredited technical personnel (electrician,
installer or authorized technical personnel) and
following all the safety instructions.
• This interface must only be inst
alled in a restricted access location.
• Before manipulate the AC indoor unit be sure it is completely disconnected from Mains power.
• In case of installation of the interface inside the AC indoor unit, fix the interface and communication cables preferabl
y to any
appropriate point of the plastic cover of the unit taking care of no blocking free movement of mobile parts and as far as possible
from tubes containing liquids and power cables.
1. Unplug the Daikin system from mains electricity.
2. Connect IntesisBox device K1 connector to
Daikin’s Indoor Unit P1P2 connector or
Wired Remote Control (if present).
3. Connect another cable from
Daikin’s Indoor Unit P1P2
to
Daikin’s
Wired Remote Control connector (if present).
4. Configure the IntesisBox switches (see below).
6. Connect the external antenna into the antenna connector.
7. Place the antenna preferably in a vertical position and pointing directly to the Wi-Fi Router or Access Point (AP).
8. Plug the Daikin system to mains electricity.
Binary value
b
0
…b
4
Decimal
value
Switches
1 2 3 4
Description
0xxx
0
x x x
Daikin Indoor Unit ambient temperature shown. (default value)
1xxx
1
x x x
Daikin Remote Controller ambient temperature shown.
xxx0
0
x x x
Slave
–
A Daikin BRC Controller must be present in P1 P2, configured as Master (default value).
xxx1
1
x x x
Master in P1 P2 bus
–
Daikin BRC Controller not needed in P1 P2. If existing, BRC must be configured as slave.
Safety instructions
Installation instructions
1. IntesisBox device
2. External antenna
3. Wi-Fi Access Point or Router
4. P1P2 connector
5. Wired Remote Controller
Switch configuration
If your device is setup as Master (SW4-OFF), IntesisBox will always show the temperature measured by the Daikin Indoor Unit.
If your device is setup as Slave (SW4-ON):
If SW1 is OFF then IntesisBox will show the temperature measured by the Daikin indoor unit.
If SW1 is ON then IntesisBox will show the temperature measured by the Daikin remote controller
NOTE:
Remember that you need to power cycle the climate system or the IntesisBox device for the changes in the switches to be applied.