top view of VacPort 

24 Volt 

Pigtail Wire 

LED 

Circuit Board 

2) pipe coupling 

co 

Connecting the VacPort to your Central Vacuum 

 

 

 

ELECTRICAL REQUIREMENTS: 

The low voltage Control Wires from your Central Vacuum Cleaner have mostly an 

output of 24volt AC. 

Note: some Central Vacuums have 24volt DC output. If your vacuum does not start --- 

just reverse the 2 wires at the wire  nuts. (Reverse the polarity). 

Maintenance: 

After a year or two the low voltage contacts in the back of the unit might be accumulating 

some dust. Flip the door quickly up and down a few times, to shake the dust off. 

Or remove the VacPort and clean around the steel rod and the circuit board. 

 

Installation: 

into a kitchen cabinet kickboard or room baseboard, flush with the floor. 

I

MPORTANT: 

DISCONNECT THE POWER TO THE CENTRAL VACUUM BEFORE INSTALLING 

 

WITH TRIM-PLATE INSTALLED: 

1) Your VacPort is supplied with a Trim-Plate in case you need more height, than the 

2-1/2” to reach with your hand into the cut-out. It is also used as a template to mark the 

cut-out. See STEP1. The minimum opening  is 6-1/8” wide x 2-1/2” height. 

2) After cutting the hole, STEP2, attach the Trim-Plate with the 2 pan head screws in one 

 

 

 

 

 

 

 

 

 

 

 

 

1) elbow with 

pipe coupling 

 

 

 

 

 

 

 

 

) Press-fit flex-hose 

ith threaded 

upling #

D900

 into 

ipe coupling. 

r hose clamp 

of the outer holes on each side, see STEP3. 

3) Connect the VacPort to your central vacuum with 2” diameter flex-hos

e. 

 

WITHOUT TRIM-PLATE INSTALLED: 

4) If you do not need the Trim-Plate, attach the VacPort directly to the wall with the 2 flat 

head screws, see STEP4. Keep Trim-Plate for future reference. 

5) See next page for wire connections. 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Please Note: The connection to the VacPort should be flexible enough so that you can 

pull the FLEXIBLE HOSE and central vacuums Low Voltage Wires out of the wall 

and connect both to the VacPort outside the wall. 

You have 3 option to connect to the VacPort: 

1) with PVC cement, glue the elbow to the pipe coupling and then to the VacPort, the other 

end of the elbow connects to a black threaded pipe coupling. Do not glue this coupling, 

just twist and press fit into elbow, check if you still can slide the VacPort with the 

flex-hose attached in or out of the cut-out. 

2) with pipe coupling, push black threaded coupling directly into pipe coupling. 

3) with the flexible hose, you can either connect the flexible hose directly with a hose 

clamp to the VacPort’s pipe or connect with the black threaded coupling to the pipe 

coupling (2) 

 

Connect the 24volt wires from the Central Vacuum to the VacPort. 

Leave slack in the wires at the connections. 

 

 

Model 