Intertherm BDELUXE 36 M36HC Installation Instructions Manual Download Page 7

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

7

FRAMING SPECIFICATIONS

Figure 10

Figure 11

Figure 12

Figure 14

Figure 15

Figure 13

Framing Dimensions

A

41 

¹⁄₄

"

1048 mm

B

37 

¹⁄₂

"

953 mm

C

28 

³⁄₄

"

730 mm

D

15 

³⁄₈

"

391 mm

E

70"

1778 mm

F

35"

889 mm

G

20 

⁵⁄₈

"

524 mm

H

19 

⁵⁄₈

"

498 mm

J

49 

¹⁄₂

"

1257 mm

Framing Dimensions for Roof

Pitch

C

D*

0/12

14 

¹⁄₂

"

14 

¹⁄₂

"

(368 mm)

(368 mm)

6/12

14 

¹⁄₂

"

17"

(368 mm)

(442 mm)

12/12

14 

¹⁄₂

"

21 

¹⁄₂

"

(368 mm)

(546 mm)

Framing Dimensions for Ceiling

Flue Type

A

B

FTF8 Vertical

14 

¹⁄₂

"

14 

¹⁄₂

"

(368 mm)

(368 mm)

FTF8 Offset 30

°

14 

¹⁄₂

"

25"

(368 mm)

(635 mm)

Note:

  All framing dimensions calcu-

lated for 1/2" dry wall at the fireplace
face.  If sheathing the chase or finish-
ing with other thickness materials,
calculations will  need to be made.

* Perpendicular to roof ridge

A

B

Ceiling Framing

C

D

Roof Framing

Header

Fireplace Framing

B

A

A

G

Inside Chase

Back Wall of Chase/Enclosure

Including Finising Materials if any

Rough

Framing Face

(Unfinished Shown)

FOAK Combustion

Air Kit

A

Outside Chase

G

C

H

Back Wall of Chase/Enclosure

Including Finising Materials

if any

Rough

Framing Face

(Unfinished Shown)

Corner Installation

J

D

A

E

F

Back Wall of

Chase/Enclosure

Including Finising

Materials

if any

Rough
Framing Face
(Unfinished Shown)

Summary of Contents for BDELUXE 36 M36HC

Page 1: ...ore beginning your installation Do not alter or modify the fireplace or its components under any circumstances Any modification or alteration of the fireplace system including but not limited to the f...

Page 2: ...our fireplace DO NOT burn wood products with synthetic binders like plywood Never burn treated construction lumber or scraps These woods burn excessively hot and may contain chemicals used to treat in...

Page 3: ...nal Fire Protection Standard for chimneys fireplaces and solid fuel burning appliances NFPA 211 and in accordance with codes such as the BOCA Basic National Codes the Standard Me chanicalCodeandtheUni...

Page 4: ...eight chart WARNING DO NOT PACK OR FILL RE QUIRED AIR SPACES WITH INSULATION OR OTHER MATERIAL NO MATERIAL IS ALLOWED IN THESE AREAS SECURE THE AIRSPACE AROUND THE CHIMNEY WITH THE FIRESTOP THIMBLE BE...

Page 5: ...ce as illustrated Figures5 6 and 7 The safety strips should overlap for continual coverage of the floor Note Safety strips are not required when fire place rests on a noncombustible surface 1 Position...

Page 6: ...es 10 through 13 on page 7 IMPORTANT UNDER NO CIRCUMSTANCES CAN THE FIREPLACE TOP SPACERS FIGURE 9 BE REMOVED OR MODIFIED NOR MAY YOU NOTCH THE HEADER TO FIT AROUND OR BE INSTALLED LOWER THAN THE SPAC...

Page 7: ...m 635 mm Note All framing dimensions calcu lated for 1 2 dry wall at the fireplace face Ifsheathingthechaseorfinish ing with other thickness materials calculations will need to be made Perpendicular t...

Page 8: ...t directly adjacent to the flange INSTALLING THE CHIMNEY SYSTEM Step 1 Before continuing check the operation of the damper as described on page 4 refer to Figure 2 Step 2 Using standard construction f...

Page 9: ...agement Check vertical alignment of chimney so that it projects from the roof in true vertical position Locking Tabs Lances Figure 21 Figure 24 Figure 22 FireCraft chimney sections do not need to be s...

Page 10: ...gs adjoining roof lines adverse wind conditions etc may require a taller chimney should the fireplace not draft properly Figure 31 Less Than 10 3 Min 2 Min 10 3 Min Locking Band Mastic Or Roof Caulkin...

Page 11: ...ections of chimney may be used between but do not exceed 20 in total length between elbows If sections of pipe exceed 10 between elbows a chimney stabilizer must be used at the midpoint see Figure 33...

Page 12: ...mber Of FTF8 Height Of Chimney Only Chimney Lengths Chimney Only Inches Feet Inches 12 18 36 48 MM M Height Of Number Of FTF8 Height Of Chimney Only Chimney Lengths Chimney Only Inches Feet Inches 12...

Page 13: ...0 0 718 1467 29 59 1 0 0 1 1 0 743 1505 31 63 1 0 2 0 1 0 794 1600 32 64 1 0 1 0 0 1 819 1638 34 68 1 0 1 1 1 0 870 1734 35 69 1 0 0 1 0 1 895 1772 37 73 1 0 0 2 1 0 946 1861 38 75 1 0 0 0 2 0 972 190...

Page 14: ...bow Figure 36 Figure 37 Underside Of Chimney Chimney Section S FTF8 E30 Return Elbow FTF8 30 Offset Elbow B A Part of Offset Return Package Model FTF8 ES30 INSTALLING OFFSETS First review the Offset E...

Page 15: ...st be caulked where it meets the black metal facing of the fireplace to avoid cold air intrusion Use noncombustible caulking material only on fireplace facing to seal Also the outside air inlet duct s...

Page 16: ...if needed Figure 43 Figure 43 Note Upper door pivot pins can also be loos ened for adjustment purposes however it is easier to loosen lower pins FIREPLACE FINISHES Mantels and Trim It is sometimes bes...

Page 17: ...e equal to or greater than R r x TL 1 19 x 1 1 19 If it is desired to elevate a marble hearth exten sion to a level of 5 or more above the floor surface What combination of noncombustible materials ca...

Page 18: ...aneling or warm brick facings Only noncombustible materials like stone tile brick etc may overlap the black front facing Do not extend these materials beyond the black facing and into the firebox area...

Page 19: ...NOTE DIAGRAMS ILLUSTRATIONS NOT TO SCALE 19...

Page 20: ...V B 04 2002 The manufacturer reserves the right to make changes at any time without notice in design materials specifications prices and also to discontinue colors styles and products Consult your loc...