Functional  and  safety  test  intervals  can  be  freely  selec-
ted  by  the  operator  in  accordance  with  the  applicable
regulations.

Repairs  may  only  be  carried  out  by  the  manufacturer  in
the factory.

All  components  have  to  be  kept  clean  and  free  of  dust
and  harmful  substances  that  could  lead  to  excessive
temperature rise.

In  the  dust  Ex  area,  the  applicable  requirements  of  EN
60079-17 and EN 60079-19 must be complied with.

11

Troubleshooting

If the heater fails, check the installation. Carry out a con-
tinuity  test  on  the  heating  circuit.  Pay  attention  to  the
connection  diagram  and  switching  point  of  the  thermo-
stat!

12

Deinstallation

Disassembly  may  only  be  carried  out  by  a  trained  per-
son.

 DANGER

Risk of fatal injury from electric current!

If contact is made with live components, there is the risk
of fatal injury.

For this reason, switch off the voltage supply, secure
against being switched on again and check that no more
voltage is present.

Disconnect connection line from the clamps and from the
connection  socket,  disconnect  device  from  bracket  and
remove it.

13

Disposal

Disassemble  the  components  of  the  product,  taking  the
applicable local labour protection and environmental reg-
ulations into consideration and make sure that the com-
ponents are recycled:

• Scrap metal

• Send plastic elements to recycling

• Sort other components according to their material

properties and dispose of them.

NOTICE

Environmental damage may be caused if dis-
posed of incorrectly!

Electrical scrap and electronics components are subject
to hazardous waste treatment and must only be dis-
posed of by certified specialists!

The  local  community  authorities  or  specialist  waste  dis-
posal  companies  can  provide  information  on  environ-
mentally friendly disposal.

14

EU declaration of conformity

The  manufacturer,  INTERTEC-Hess  GmbH,  Raffiner-
iestrasse  8,  93333  Neustadt/Donau,  Germany,  hereby
declares in sole responsibility that the product

Product / Type designation:

SL MICROTHERM

complies  with  the  provisions  of  the  following  directives
2014/34/EU  (ATEX),  2014/30/EU  (EMC),  2011/65/EU
(RoHS), 2012/19/EU (WEEE) complies with the following
standards,  harmonized  standards,  where  appropriate
and/or standardized documents:

EN IEC 60529:1991+A1:2000+A2:2013

EN IEC 60079-0:2018

EN IEC 60079-1:2014

EN IEC 60079-31:2014

EN IEC 61000-6-4:2007+A1:2011

Harmonized Standard (RoHS):

DIN EN IEC 63000:2019

Designation:

0102

II 2 G Ex db IIC T6, T5, T4, T3 Gb

II 2 D Ex tb IIIC T85°C, T100°C, T135°C, T200°C Db

PTB 02 ATEX 1116 X

Neustadt, January 28th, 2020

Summary of Contents for SL MICROTHERM DNA

Page 1: ...Operating Instruction SL MICROTHERM DNA HOM235356171Ien 6 03 02 2020...

Page 2: ...contents 1 General 3 2 Use 3 3 Explanation of symbols for warnings and signal words 3 4 Safety information 3 5 Installation accessories 4 6 Technical Data 4 7 Installation 4 8 Connection 5 9 Commissi...

Page 3: ...n necting cable If a TAE is used the respective operating instructions must be complied with EC type examination certificates PTB 02 ATEX 1116 X with appendices and supplements in German and Eng lish...

Page 4: ...witching capacity of fault alarm AM 10 A 275 V AC Connecting cable Silicone hose cable notch and oil resistant 3 x 1 5 mm Connecting cable AM Silicone hose cable notch and oil resistant 5 x 1 0 mm 8 5...

Page 5: ...mal quick release set to 10 A as short circuit protection When using a heater without in tegrated thermostat the fuse protection can be selected according to the cross section of the supply cable Addi...

Page 6: ...ue ye gn yellow green bk black gy grey Illustration 4 SL THERM with TS 9 Commissioning If the heater is installed in accordance with the notes in the Installation Page 4 section and Connection Page 5...

Page 7: ...ve it 13 Disposal Disassemble the components of the product taking the applicable local labour protection and environmental reg ulations into consideration and make sure that the com ponents are recyc...

Page 8: ...ontact person or dir ectly contact INTERTEC Hess GmbH Raffineriestr 8 93333 Neustadt Donau Germany Phone 49 9445 9532 0 e mail info intertec info Website www intertec info Warranty The legally defined...

Reviews: