Operating Instruction
SL MICROTHERM DNA
HOM235356171Ien-6 • 03/02/2020
Page 1: ...Operating Instruction SL MICROTHERM DNA HOM235356171Ien 6 03 02 2020...
Page 2: ...contents 1 General 3 2 Use 3 3 Explanation of symbols for warnings and signal words 3 4 Safety information 3 5 Installation accessories 4 6 Technical Data 4 7 Installation 4 8 Connection 5 9 Commissi...
Page 3: ...n necting cable If a TAE is used the respective operating instructions must be complied with EC type examination certificates PTB 02 ATEX 1116 X with appendices and supplements in German and Eng lish...
Page 4: ...witching capacity of fault alarm AM 10 A 275 V AC Connecting cable Silicone hose cable notch and oil resistant 3 x 1 5 mm Connecting cable AM Silicone hose cable notch and oil resistant 5 x 1 0 mm 8 5...
Page 5: ...mal quick release set to 10 A as short circuit protection When using a heater without in tegrated thermostat the fuse protection can be selected according to the cross section of the supply cable Addi...
Page 6: ...ue ye gn yellow green bk black gy grey Illustration 4 SL THERM with TS 9 Commissioning If the heater is installed in accordance with the notes in the Installation Page 4 section and Connection Page 5...
Page 7: ...ve it 13 Disposal Disassemble the components of the product taking the applicable local labour protection and environmental reg ulations into consideration and make sure that the com ponents are recyc...
Page 8: ...ontact person or dir ectly contact INTERTEC Hess GmbH Raffineriestr 8 93333 Neustadt Donau Germany Phone 49 9445 9532 0 e mail info intertec info Website www intertec info Warranty The legally defined...