Repairs  may  only  be  carried  out  by  the  manufacturer  in
the factory.

All  components  have  to  be  kept  clean  and  free  of  dust
and  harmful  substances  that  could  lead  to  excessive
temperature rise.

11

Troubleshooting

If the heater fails, check the installation. Carry out a con-
tinuity  test  on  the  heating  circuit.  Pay  attention  to  the
connection  diagram  and  switching  point  of  the  thermo-
stat!

In the case of overheating, the thermal indicator (see fig-
ure) indicates a discoloration. If more than four fields are
blackened,  the  heater  must  be  uninstalled  and  returned
to the manufacturer for inspection.

Illustration 7: 

Temperature indicator

12

Deinstallation

Disassembly  may  only  be  carried  out  by  a  trained  per-
son.

 DANGER

Risk of fatal injury from electric current!

If contact is made with live components, there is the risk
of fatal injury.

For this reason, switch off the voltage supply, secure
against being switched on again and check that no more
voltage is present.

Disconnect connection line from the clamps and from the
connection  socket,  disconnect  device  from  bracket  and
remove it.

13

Disposal

Disassemble  the  components  of  the  product,  taking  the
applicable local labour protection and environmental reg-
ulations into consideration and make sure that the com-
ponents are recycled:

• Scrap metal

• Send plastic elements to recycling

• Sort other components according to their material

properties and dispose of them.

NOTICE

Environmental damage may be caused if dis-
posed of incorrectly!

Electrical scrap and electronics components are subject
to hazardous waste treatment and must only be dis-
posed of by certified specialists!

The  local  community  authorities  or  specialist  waste  dis-
posal  companies  can  provide  information  on  environ-
mentally friendly disposal.

14

EU declaration of conformity

The  manufacturer,  INTERTEC-Hess  GmbH,  Raffiner-
iestrasse  8,  93333  Neustadt/Donau,  Germany,  hereby
declares in sole responsibility that the product

Product / Type designation:

CP HORIZOTHERM

complies  with  the  provisions  of  the  following  directives
2014/35/EU  (LVD),  2014/30/EU  (EMC),  2011/65/EU
(RoHS), 2012/19/EU (WEEE) complies with the following
standards,  harmonized  standards,  where  appropriate
and/or standardized documents:

EN IEC 60364

EN IEC 61000-6-4:2007+A1:2011

Harmonized Standard (RoHS):

DIN EN IEC 63000:2019

Designation:

Neustadt, January 28th, 2020

Dipl.-Ing. Martin Hess, Managing Director

15

Further information and service

If  the  information  contained  in  this  instruction  manual
should  not  be  sufficient  in  any  way,  then  INTERTEC
would be glad to be at your disposal to provide further in-
formation and service.

Summary of Contents for CP HORIZOTHERM DNNA

Page 1: ...Operating Instructions CP HORIZOTHERM DNNA HOM178902027Ien 5 05 02 2020...

Page 2: ...contents 1 General 3 2 Use 3 3 Explanation of symbols for warnings and signal words 3 4 Safety information 3 5 Installation accessories 4 6 Technical Data 4 7 Installation 4 8 Connection 5 9 Commissi...

Page 3: ...ing temperature If a TAE is used the respective operating instructions must be complied with 3 Explanation of symbols for warnings and signal words The safety information warns the user about risks an...

Page 4: ...sponding power adjustment and component selection are possible Profile type N Height x Width x Depth 152 x 155 x 40 mm Profile type N Length x Width x Height 155 x 152 x 40 mm INFO You will find the p...

Page 5: ...then the heater is at its rated output Mains voltage fluctuations up to 10 are then permissible Each heater with integrated TS thermostat must be pre ceded by a 10 A fuse or a motor protection switch...

Page 6: ...THERM with TS 9 Commissioning If the heater is installed in accordance with the notes in the Installation Page 4 section and Connection Page 5 sections then the radiator may be commis sioned CAUTION S...

Page 7: ...e the components of the product taking the applicable local labour protection and environmental reg ulations into consideration and make sure that the com ponents are recycled Scrap metal Send plastic...

Page 8: ...fo intertec info Website www intertec info Warranty The legally defined warranties and warranty periods of 24 months are applicable to our scope of supply and ser vices You will find more detailed inf...

Reviews: