• Sort other components according to their material

properties and dispose of them.

NOTICE

Environmental damage may be caused if
disposed of incorrectly!

Electrical scrap and electronics components are subject
to hazardous waste treatment and must only be
disposed of by certified specialists!

The  local  community  authorities  or  specialist  waste
disposal  companies  can  provide  information  on
environmentally friendly disposal.

14

Declaration of Conformity

The 

manufacturer, 

INTERTEC-Hess 

GmbH,

Raffineriestrasse  8,  93333  Neustadt/Donau,  Germany,
hereby declares in sole responsibility that the product

Product / Type designation:

CP FLATTHERM

was  manufactured  according  to  GB  3836.13-2013,  GB
3836.15-2000,  GB  3836.16-2006,  GB  50257-2014,  GB
12476.2-2010,  GB  15577-2007  and  complies  with  the
following  standards,  harmonized  standards,  where
appropriate and/or standardized documents:

GB 3836.1-2010

GB 3836.2-2010

GB 12476.1-2013

GB 12476.5-2013

Marking:

Ex db IIC T6~T3

Ex tD A21 IP66/IP68 T85°C,T100°C,T135°C,T200°C

CCC cert. no. : 2020322312003123

Neustadt, May 2nd, 2018

Dipl.-Ing. Martin Hess, Managing Director

15

Further information and service

If  the  information  contained  in  this  instruction  manual
should  not  be  sufficient  in  any  way,  then  INTERTEC
would  be  glad  to  be  at  your  disposal  to  provide  further
information and service.

Please  contact  your  INTERTEC  contact  person  or
directly contact

INTERTEC-Hess GmbH

Raffineriestr. 8

93333 Neustadt/Donau

Germany

Phone: +49 9445 9532-0

e-mail: [email protected]

Website: www.intertec.info

Warranty

The  legally  defined  warranties  and  warranty  periods  of
24  months  are  applicable  to  our  scope  of  supply  and
services.

You  will  find  more  detailed  information  in  the
manufacturer  warranty  from  INTERTEC  for  heating
systems and accessories.

These instructions do not claim to take all

designs, options or changes into

consideration, even in association with

installation, operation or maintenance.

INTERTEC does not accept responsibility

for providing information about changes

made retrospectively.

16

Certificate CCC

See also

2

CCC certificate CP ...THERM No.
2020322312003123 valid_20251102 [

}

 7]

16.1 CCC certificate CP ...THERM No.

2020322312003123 valid_20251102

Summary of Contents for CP FLATTHERM DC.A HI

Page 1: ...Operating Instructions CP FLATTHERM DC A HI HOM2540616203Ien 0 14 12 2021 ...

Page 2: ...s and signal words 3 5 Safety information 4 6 Technical Data 4 7 Installation 4 8 Connection 5 9 Commissioning 6 10 Maintenance 6 11 Troubleshooting 6 12 Deinstallation 6 13 Disposal 6 14 Declaration of Conformity 7 15 Further information and service 7 16 Certificate CCC 7 16 1 CCC certificate CP THERM No 2020322312003123 valid_20251102 7 ...

Page 3: ...us for explosive gas atmospheres Part 15 Electrical installations in hazardous areas other than mines GB 3836 16 2006 Electrical apparatus for explosive gas atmospheres Part 16 Inspection and maintenance of electrical installation other than mines GB 50257 2014 Code for construction and acceptance of electric equipment on fire and explosion hazard electrical equipment installation engineering GB 1...

Page 4: ... resistant 3 x 1 0 mm Ø8 5 mm Material Seawater proof aluminium black anodized Mean Time Before Failure 50 000 h Storage temperature 60 to 80 C Connecting cable HI Silicone hose cable notch and oil resistant 2 x 0 62 mm and 3 x 1 35 mm Ø10 2 mm Special voltages with corresponding power adjustment and component selection are possible Profile type P Height x Width x Depth 220 x 200 x 30 mm INFO You ...

Page 5: ...The device may only be connected up and secured by a trained person taking into account the rated voltage and rated current specified on the nameplate Where operating voltage measured voltage rated voltage then the heater is at its rated output Mains voltage fluctuations up to 10 are then permissible Each heater with integrated TS thermostat must be preceded by a 10 A fuse or a motor protection sw...

Page 6: ...ee of dust and harmful substances that could lead to excessive temperature rise In the dust Ex area the applicable requirements of GB 3836 13 2013 must be complied with 11 Troubleshooting If the heater fails check the installation Carry out a continuity test on the heating circuit Pay attention to the connection diagram and switching point of the thermostat In the case of overheating the thermal i...

Page 7: ... db IIC T6 T3 Ex tD A21 IP66 IP68 T85 C T100 C T135 C T200 C CCC cert no 2020322312003123 Neustadt May 2nd 2018 Dipl Ing Martin Hess Managing Director 15 Further information and service If the information contained in this instruction manual should not be sufficient in any way then INTERTEC would be glad to be at your disposal to provide further information and service Please contact your INTERTEC...

Page 8: ...rtec Hess GmbH Schroep I erstrasse 37 85053 I ngo I stadt Germany lntertec Hess GmbH Raffineriestrasse 8 93333 Neustadt Donau Germany 加热器 CP a THERM b c d e f g h GB 3836 1 2010 GB 3836 2 2010 GB 3836 9 2014 GB 12476 1 2013 GB 12476 5 2013 上述产品符合强制性产品认证实施规则CNCA C23 01 2019的要求 特发此证 发 证 日 期 2020年11月3日 首次发证日期 2020年11月3日 有 效 期至 2025年11月2日 证书有效期内本证书的有效性依据发证机构的定期监督获得保持 本证书的相关信息可通过国家认监委网站 www cnca gov cn...

Page 9: ... 3836 2 2010 GB 3836 9 2014 GB 12476 1 2013 GB 12476 5 2013 This is to certify that the above mentioned product s complies with the requirements of implementation rules for compulsory certification REFNO CNCA C23 01 2019 Valid from November 3 2020 Valid until November 2 2025 Date of original certification November 3 2020 The validity of this certificate is subject to positive result of the regular...

Page 10: ... 附 件 产品名称 加热器 型号规格 CP a THERM b c d e f fl h 与防爆无关代码 B C D C K L M N 0 P R S T U A S 700 T6 TS T4 T3 XXX TSXX TAIXX AM HI X SF DF BF M M20 M20L F F16 S 防爆标志 电气参数 Ex db IIC T6 T3 Ex tD A21 IP66 IP68 T85 C T100 C T135 C T200 C 最高额定电压 l 最高额定电流 l 最大额定功率 250V 10A 700W 批准 令邑 上海仪器仪表自控系统检验测试所有限公司 http www sitiias com cn 中闱 上海外曹宝路103号200233 第1页共1页 电话 86 21 64510844 ...

Reviews: