5 CHARGING THE CYLINDER WITH AIR
1.
Connect the quick-fill adapter, see [figure 1], to the air supply or compressor via
the charging hose.
NOTE:
THE FILL ADAPTER MUST BE SUPPLIED WITH THE FULL CHARGING PRESSURE BEFORE THE SPIROSCAPE IS
CONNECTED.
2.
Break the seal [ref a, figure 5].
3.
Open the Velcro fastener of the bag.
4.
Open the zip of the bag.
5.
Uncover the cylinder valve knob.
6.
Disconnect the air hose from the cylinder valve by removing the pin [ref b, figure
5]. To avoid losing the pin, refit it to the air hose.
7.
Carefully attach the quick-fill adapter by hand. Turn it clockwise until air can be
heard flowing, then turn it a quarter-turn further.
8.
Charge the cylinder until the gauge shows full. Wait for the cylinder to cool down,
then “top up” the cylinder until the gauge again shows full.
NOTE:
IF THE AIR SUPPLY IS ACTIVATED DURING THE CHARGING PROCESS, TURN THE CYLINDER VALVE KNOB
COUNTER-CLOCKWISE UNTIL THE AIR STOPS FLOWING.
9.
Unscrew the quick-fill adapter.
10.
Re-connect the air hose to the cylinder valve with the pin [ref b, figure 5].
NOTE:
MAKE SURE THAT THE QUICK-START RING [REF D, FIGURE 5] IS NOT UNDER THE HOSE WHEN YOU RE-
CONNECT THE HOSE.
11.
Pack the SPIROSCAPE as described in the instructions in chapter 6.