24
2.
Connect the quick coupling of the SCBA to the airline supply hose. The higher
pressure in the supply hose should shut off the supply from the SCBA.
3.
After two minutes, read the pressure displayed on the pressure gauge again.
During the elapsed time, there should be no measurable drop in pressure on the
gauge. This check will indicate that the higher pressure in the airline supply hose
is preventing air from being taken from the SCBA cylinder.
4.
During usage in the hazardous environment, periodically check the pressure
displayed on the gauge and if a decrease is noted discontinue use. Disconnect
the airline hose and exit to a safe area using the bail-out set and an escape
apparatus.
17 MARKINGS
A.
Manufacturer
B.
Model designation
C.
Serial No
D.
European standard and classification
E.
Year of manufacture
A
B
C
D
E
THIS PRODUCT SHOULD NOT BE DISPOSED OF IN GENERAL MUNICIPAL WASTE
1.
The crossed-out wheeled bin symbol, on this product, its packaging or
instructions indicates that the product was manufactured after 13/8/05 and is
subject to European Community directive 2002/96/EC, issued 27/1/03, on the
correct handling of Waste Electronic and Electrical Equipment (WEEE).
2.
WEEE must not be disposed of in general waste and should be collected and
disposed of by waste collectors appropriately licensed for special waste.
3.
This product contains substances deemed potentially harmful to the environment
or human health if disposed of incorrectly.