2. Functional Description
2.3
Quick Start Guide
(1) Gather the external supply and equipment needed to operate the board:
(a) 4V to 30V DC power supply
(b) Precision Voltmeter (Agilent 3458A digital multimeter or equivalent)
(2) Attach the evaluation board to a DC power supply at test points TP1 and TP2 labeled VIN and GND as shown
in
. Place the positive terminal at VIN (TP1) and the negative terminal at GND. The supply should be
capable of delivering 4V to 30V of power and 100mA of current.
(3) Connect a precision voltmeter at test points TP3 and TP4 labeled VOUT and GND as shown in
.
(4) Set the supply voltage to 5V.
(5) Turn the DC power supply ON. The voltmeter should read 2.5V ± 0.05%.
(6) Change the DC power supply voltage to 10V. The voltmeter should continue to read 2.5V.
(7) Vary the DC power supply voltage over the range of 4V to 30V. The voltmeter should continue to read 2.5V.
(8) Performance at different resistive loads can be evaluated by changing R2 with different resistor values.
Figure 2. Basic Evaluation Test Setup Block Diagram (Measuring Voltage Reference VOUT)
4V
to
30V
DC PO
WER
SUPP
LY
ISL71010BM25EV1ZEVAL1Z
-
+
C4
C3
TP1
R1
VIN
VOUT
TP4
GND
GND
TP2
TP3
C1
U1
Pr
ec
is
ion
Vo
ltm
et
e
r
C2
C5
REV A
+-