Interroll Diverter SH 1500
Maintenance and repair
60
Version 1.0 (06/2022) en
Translation of original operating instructions
Replacing the return
wheel (outside)
1
2
3
2
1
3
Replacing the return wheel (outside)
1
Torx screw
3
Return wheel
2
Side frame
DANGER
Danger to life from electrocution and crushing
Installation and maintenance tasks on 400-V conveyor systems while they are in operation can
cause life-threatening electrocution and serious crushing.
4
Power down the entire conveyor module and ensure that it cannot be started accidentally.
Requirement:
R
The module is shut down.
4
Remove the ball module conveyor,
see "Replacing the ball module conveyor", page 56
4
Remove the side covers,
see "Removing/installing the side plates", page 51
4
Take the return wheel at the front and rear out of the side frames: Unscrew screws (1) on the
right and left in the side frames (2) and remove the return wheel (3) to the side.
4
Properly dispose of the old return wheel.
4
Place new return wheel (3) between the side frames (2) and fasten with screw (1) on the right
and left at the side frames (2) from the outside.
4
Reattach side covers and ball module conveyor in reverse order.