Version 2.0 (12/2019) Online
Translation of the original operating manual
17 von 38
Product information
3.6
DIP-Schalter
The DIP switches are used to select the gear ratio of the previously used RollerDrive EC300 and RollerDrive EC310 to
be used in the future. Based on these values, the AdControl determines the necessary change that has to be made to
the speed signal.
In its as-delivered state, the gear ratio EC300 13:1 and EC310 16:1 are set.
DIP switches
Meaning
7,85:1 / 13:1
Gear ratio of the RollerDrive EC300
Bit 0, Bit 1, Bit 2, Bit 3
Gear ratio of the RollerDrive EC310 (see below)
Reserve
Not occupied
Gear ratio
RollerDrive EC310
DIP switches
Bit 3
Bit 2
Bit 1
Bit 0
9:1
OFF
OFF
OFF
OFF
12:1
OFF
OFF
OFF
ON
16:1
OFF
OFF
ON
OFF
20:1
OFF
OFF
ON
ON
24:1
OFF
ON
OFF
OFF
36:1
OFF
ON
OFF
ON
48:1
OFF
ON
ON
OFF
64:1
OFF
ON
ON
ON
96:1
ON
OFF
OFF
OFF
If a different DIP switch combination is set than the one listed in the table, the RollerDrive speed of rotation