UDM108-01
16
RSA2024-TB/2”
Set-Up Procedure
Tape Threading - Upper Tape Head
Remove the blade guard from the knife in the Tape head.
NOTE: TURN OFF ELECTRICAL
POWER SUPPLY AND DISCONNECT THE POWER CORD FROM THE
ELECTRICAL SUPPLY BEFORE BEGINNING TO WORK ON THE TAPE HEADS OR
TO LOAD TAPE. IF POWER CORDS ARE NOT DISCONNECTED, SEVERE INJURY
TO PERSONNEL COULD RESULT. THE KNIFE CONTAINED IN THE TAPE HEAD
IS EXTREMELY SHARP. USE CAUTION WHEN REMOVING THE BLADE GUARD
AND THREADING THE TAPE TO AVOID PERSONNEL INJURY.
To thread the tape
into the Upper Tape Head you do not require any special tools. Pull approximately 12" of tape
from the roll and fold in half. This allows you to thread the tape without it adhering to the guide
and clutch rollers inside the tape head. Follow the Tape Threading Diagram on the side plate of
the HSD
®
2000 Tape Head. See your Tape Head manual for further information if required.
Tape Threading - Lower Tape Head
Lift Top tape Head Box to the uppermost position by activating the
“BLOCKED”
selector
switch on the control box. Remove the Lower tape Head by grasping the tape application rollers
and lifting straight up. Remove the blade guard from the knife in the Tape head.
NOTE: THE
KNIFE CONTAINED IN THE TAPE HEAD IS EXTREMELY SHARP. USE CAUTION
WHEN REMOVING THE BLADE GUARD AND THREADING THE TAPE TO AVOID
PERSONNEL INJURY.
To thread the tape into the Lower Tape Head you do not require any
special tools. Pull approximately 12" of tape from the roll and fold in half. This allows you to
thread the tape without it adhering to the guide and clutch rollers inside the tape head. Follow the
Tape threading diagram on the side plate of the HSD
®
2000 Tape Head. See your Tape Head
manual for further information if required. Replace the Lower tape head in the machine. Turn off
the
“BLOCKED”
selector switch.
Electrical Connection
A twelve (12) foot standard three conductor power cord with plug is provided for 115 V, 60 Hz,
15 amp electrical service. The servicing receptacle must be properly grounded. Before the
machine is plugged into the receptacle, ensure that all materials are removed from the machine.
Note: Use of an extension cord is not recommended because of voltage drop.
The electrical control is protected with an
automatic circuit breaker with re-settable
overload. This reset is located in the electrical
box in the lower left quadrant (Fig. 9). Push
on the blue button to reset.
Figure 10
Summary of Contents for ipg RSA 2024-TB/2"
Page 22: ...UDM108 01 22 RSA2024 TB 2 ELECTRIC DIAGRAM...
Page 23: ...UDM108 01 23 RSA2024 TB 2 PNEUMATIC DIAGRAM...
Page 24: ...24 APPENDIX A PARTS LISTS UM108TW...
Page 25: ...25 1 5 8 4 6 3 7 2 9 UM108TW...
Page 27: ...27 1 2 8 6 4 3 5 7 USM5050...
Page 29: ...29 3 4 5 6 3 2 7 3 4 5 1 UAM0400...
Page 31: ...31 1 7 11 3 5 6 4 2 10 7 9 8 UAM0170EV...
Page 35: ...35 1 17 7 15 2 6 16 16 6 12 14 12 13 3 8 5 4 10 9 11 18 UAM0411...
Page 37: ...37 1 2 5 3 13 16 17 17 18 9 19 20 4 14 15 21 6 8 12 11 7 10 USM5051...
Page 46: ...46...
Page 47: ...47 8 9 10 1 10 9 8 3 4 15 13 7 6 11 12 14 5 10 9 8 2 USM5055...
Page 49: ...49 8 9 10 1 3 6 7 11 12 14 5 3 4 10 9 8 15 13 10 9 8 2 USM5056...
Page 51: ...51 1 2 13 12 11 6 10 4 9 7 3 8 5 UAM0406...
Page 53: ...53 2 1 13 12 6 10 4 7 8 5 9 11 3 UAM0405...
Page 56: ...56 USM5058...
Page 58: ...58...