950-0154revD - 7 - April 19, 2012
REMOTE CONTROL FUNCTIONS
Note: Be sure there are no obstructions between the remote control and the receiver. Remote
control units are interchangeable, and are not assigned to a particular indoor unit. Indoor
controller will beep each time it receives a command from the remote control. Keep the remote
control away from moisture and excessive heat.TIP: Each remote will control any or all the indoor
units.
ON/OFF
-Turns the unit on or off. There is a 3 minute compressor delay when the unit is turned
on.
MODE
– Pressing the MODE button will select between AUTO, COOL, DRY, FAN, or HEAT.
AUTO mode - Set point temperature will not be shown on the remote control display and
cannot be changed. Temperature is automatically set to 68 °F to 77 °F and will switch
between COOL, HEAT or FAN mode to maintain the temperature. If the temperature
goes below 68 °F the unit will switch to HEAT mode. If the temperature goes above 77 °F
unit switches to COOL mode. If temperature is in between the temperatures it runs in the
FAN mode.
On rare occasions while running in the AUTO mode with other zones activated there may
be an “E7” error code. “E7” error code occurs when 2 or more units are set to run in
different modes, such as HEAT and COOL. In the AUTO mode the unit automatically
switches between HEAT, COOL or FAN. If other zones are set to HEAT or COOL while
the AUTO is running in an opposite mode an “E7” will occur. To rectify this condition you
must set all the indoor units to the same mode, either HEAT or COOL, or leave the unit
alone and when the temperature returns to the point where the unit switches back to the
correct mode (as the other indoor units) and all zones are in the HEAT or COOL mode, it
will clear itself and begin to run again.
COOL mode
– Unit cools room to set point temperature. Set point temperature can be set
from 61 °F to 86 °F. Outdoor unit will operate in outside temperatures of +4 to +118 ºF in
the cooling mode. Indoor fan does not turn off in the cooling mode when temperature set
point has been satisfied. It will continue to run to keep the room temperature consistent.
HEAT mode - Unit heats room to set point temperature. Set point temperature can be set
from 61 °F to 86 °F. Outdoor unit will operate in outside temperatures of -5 ºF to +75 ºF in
ON/OFF
– Turns unit on or off.
-/+ - Raise, Lower set point.
FAN
– Set fan speed, hi, med, lo, auto.
LOUVER
– Set louver swing.
CLOCK
– Set clock.
TIMER ON
– Set timer on time.
PURGE
– Extended on time for fan.
TEMP
– Set point, inside, outside,
temperature display.
TIMER OFF
– Set timer off time.
TURBO
– Maximum fan speed.
SLEEP
– Toggle on/off SLEEP mode.
DISPLAY
– Turns display on wall unit on
or off.
LOCK KEY PAD
– No changes can be
made.
º
F or
º
C
– Select
º
F or
º
C.
KEY PAD FUNCTIONS
PURGE
DISPLAY
TIMER OFF