8
Trouble Shooting
9
Problem
Possible Cause
Remedy
Unit does not turn on.
Power cord not plugged
in.
Plug power cord into
suitable outlet with
correct voltage.
Circuit breaker in
building tripped.
Reset circuit breaker at
panel box.
Faulty power outlet.
Try another outlet.
Fuse is blown on back of
unit.
Replace fuse with
correct replacement.
Unit keeps blowing
fuses.
Too small amperage
fuse being used.
Replace fuse with
correct fuse as specified
on the back panel of
unit.
Electrical short circuit.
Return unit to
manufacturer for repair.
Unit does not produce
ozone.
Damage or malfunction
in "
-
" module or
SP ARC
tranfsormer.
Return unit to
manufacturer for repair.
Maintenance
Your Total Zone ozone generator was engineered, designed and built to
require very little maintenance. The only maintenance necessary to keep
your Total Zone running at peak performance is to rinse the stainless steel
intake filter(s) located on the back of the unit with soap and water, air dry,
then re-install. If you ever feel that your Total Zone is not producing ozone at
the level it did when it was new, call the factory for a
number and ship
RMA
the unit back. We will inspect and diagnose the problem. If the equipment
only needs adjustments or cleaning to bring it back into specifications we
will gladly service and re-certify your equipment
, you only
free of charge
pay shipping and handling.
Your Total Zone Ozone Generator should be returned to the factory
once every two (2) years for cleaning, adjusting and re-certification.