background image

 

Patriot Twin Analyst – Owner’s Manual – Owner’s Manual – Revision 1.1 

Page 

1

 

 

 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 

 

 

 

 

 

 

Owner’s Manual 

Patriot Twin Analyst 

Summary of Contents for Patriot Twin Analyst

Page 1: ...Patriot Twin Analyst Owner s Manual Owner s Manual Revision 1 1 Page 1 Owner s Manual Patriot Twin Analyst...

Page 2: ...asteless and can sometimes be life threatening The state ment my parents drank this water for 75 years and it never hurt them is no longer a valid excuse to not be concerned with water quality There h...

Page 3: ...here are several degrees of water hardness Even moderately hard water can seriously damage the plumbing system in your home and in time cause inconvenient and expensive problems Hard water is a poor c...

Page 4: ...ard water affects your house plumbing Perhaps the greatest damage done by hard water is the damage that you can t easily see Water heaters hu midifiers boilers and household pipes become lined with an...

Page 5: ...INE Increased Water Heating Costs Damaged Clothing Excessive Soap Consumption Pipe Scaling Faucet and Fixture Damage Skin Problems Unpalatable Food Undesirable Tastes and Odors Premature Appliance Fai...

Page 6: ...control center can be up dated with the latest software updates upgrades as they become available Reliable The mechanical subsystem in the Patriot Twin Analyst System is revolutionary in its own right...

Page 7: ...ith your local water professional to decide on the best salt for your applica tion Pur Gard The Pur Gard injection feeder should be kept full to ensure proper system operation and maximum efficiency P...

Page 8: ...unts of Pur Gard depending on your water consump tion habits always maximizing efficiency and performance while providing you with the water quality that you deserve Pur Gard is designed to Clean ion...

Page 9: ...gus that can enter the system through safe city water salt or even from the air These additional contam inants slowly accumulate in your softener and can even colonize it with a biofilm of Heterotroph...

Page 10: ...ping handling Allow water to run until clear Observe water for particles If resin particles are found in the water bypass the sys tem and call tech support Leave the bathtub running Program the system...

Page 11: ...Patriot Twin Analyst Owner s Manual Owner s Manual Revision 1 1 Page 11...

Page 12: ...ogramming to indicate if the displayed parameter is locked icon flashes when controller is in Level I 10 When x2 is displayed a second regeneration has been scheduled 11 Recycle icon displayed flashin...

Page 13: ...g Mode In deep cleaning mode the display shows the current cleaning cycle step and the remaining time for that cycle to execute Flow meter In service mode the display will show the time of day and rem...

Page 14: ...RA CYCLE Used to instruct the controller to regenerate Time of Day Set the current time of day Hardness Set the compensated hardness level A compensated hardness level is the amount of actual calcium...

Page 15: ...essing SET for 3 seconds at H0 will reset control to factory defaults Delayed Manual Regeneration Press and release the REGENERATE button Press REGENERATE button again to cancel Immediate Manual Regen...

Page 16: ...104 m3 H7 Average usage for Sunday in gallons or m3 0 131 070 gallons or 0 1 310 70 m3 H8 Average usage for Monday in gallons or m3 0 131 070 gallons or 0 1 310 70 m3 H9 Average usage for Tuesday in...

Page 17: ...f hardness and other contaminants before becoming exhausted This is referred to as the capacity of the resin The capacity of the resin is referred to as grains of cal cium carbonate hardness removed p...

Page 18: ...n it should clean itself using the latest algo rithms that consider your water usage habits water hardness and the status of its resin exhaustion sensors Your system will periodically perform an antib...

Page 19: ...the media bed and out of tank to drain Tank Fill Your system will add the prescribed amount of water to the salt tank compressing the media bed and preparing it for ser vice Brine Draw Your system wi...

Page 20: ...fer to problem System fails to clean Valve fails to draw brine Refer to problem Valve fails to draw brine Decreasing exchange capacity of resin Clean or replace resin bed No salt in brine tank Add sal...

Page 21: ...ctions Restricted Obstructed brine line Check brine line for kinks restrictions or obstructions Leak in brine line Verify brine line and connections for air leakage Insufficient water in brine tank Re...

Page 22: ...brine tank Unit regenerates too frequently Check household for excessive or unexpected water usage leaky toilet fill valves T P Relief drainage Reverse Osmosis processors humidifiers plumbing leaks et...

Page 23: ...ropriate remedial action Cause Solution Mineral or iron build up in resin tank Clean resin bed and control valve increase regeneration frequency Increase Pur Gard dosage rate Plugged lower and or uppe...

Page 24: ...se required by applicable law Intermountain Soft Water shall not be liable for any damages whatsoever including without limitation loss time inconvenience expenses such as telephone calls labor or mat...

Reviews: