background image

8.  The hours digit of the  

current day’s DAWN time 

flashes on the display.
•  Press +  or - to adjust the 

hour, as necessary.

•  Press ON/OFF to confirm 

and advance to the DAWN 

minutes digit.

•  Press +  or - to adjust the minutes, as 

necessary

•  Press ON/OFF to confirm and advance to the 

DUSK hours digit.

•  Use the same process for setting the DAWN 

time to set the time for DUSK.

Note: 

Locate the current day’s dusk and dawn times in a 
local paper or online. You may deliberately adjust 
DUSK and/or DAWN settings up to +/- 120 minutes, 
if desired, to cause Astronomic events to always 
occur a predictable amount of time before or after the 
actual dusk or dawn.

9.  The timer loops to the beginning of the SETUP 

mode. 
•  Press ON/OFF repeatedly to review/revise your 

settings, or press MODE to exit SETUP.

Programming Events

Note: 

Program ON and OFF events as separate events.

1.  Press MODE until PGM  

appears on the display.

2.  Press ON/OFF to confirm. An 

event number flashes on the 

display. 

Note: 

If this is the first event,  
you will see 01.

3.  Press ON/OFF to confirm the 

event number. An event type 

flashes on the display.

4.  Use + to select the event type.

•  ON - sets an ON event 
•  SKIP - stops the event
•  OFF - sets an OFF event

5.  Press ON/OFF to confirm. An 

event time type flashes on the display.

6.  Use + to select a time type. 

•  DAWN
•  DUSK
•  Fixed Time

Note: 

To set a Fixed Time, press ON/OFF, then + or - to 
adjust the hour. Press ON/OFF. Use the same 
process to set minutes. Press ON/OFF to confirm.

7.  Press ON/OFF to confirm. A day selection flashes 

on the display.

ST01/ST01K/EI600

In-Wall Timer with Astro Feature

Installation and User Guide

RATINGS

ST01/ST01K

EI600

Operating 

Voltage

120-277 VAC, 50/60 Hz

Resistive 

(heater)

15 A, 120-277 VAC

20 A, 120-277 VAC

Tungsten 

(incandescent)

15 A, 120 VAC; 6 A, 208-277 VAC

Ballast 

(fluorescent)

8 A, 120 VAC; 

4 A, 208-277 VAC

16 A, 120-277 VAC

Motors

1 HP, 120 VAC; 2 HP, 240 VAC

DC Loads

4 A, 12 VDC; 2 A, 28 VDC

Operating 

Temperature

32° F to 104° F (0° C to 40° C)

Dimensions

4 1⁄8” H x 1 3⁄4” W x 1 13⁄16” D

SAFETY SECTION

WARNING

Risk of Fire or Electric Shock

•  Disconnect power at the circuit breaker(s) or disconnect 

switch(es) before installing or servicing (including replacing the 

battery).

•  Installation and/or wiring must be in accordance with national 

and local electrical code requirements.

•  Use COPPER conductors ONLY.

•  Do Not recharge, disassemble, heat above 212° F (100° C), 

crush, or incinerate the Lithium battery. Keep out of reach of 

children. 

•  Replace battery with Type CR2 only that is certified by 

Underwriters Laboratories (UL).

•  Do NOT use timer to control devices that could have dangerous 

consequences due to inaccurate timing, such as: sun lamps, 

saunas, heaters, slow cookers, etc.

NOTICE

•  Risk of timer damage due to leakage if weak battery is not 

replaced promptly. 

•  Dispose of product per local regulations for disposal of Lithium 

batteries.

Spring Grove, Illinois 60081
www.intermatic.com

PRODUCT DESCRIPTION

The ST01 Series and EI600 Series In-Wall Timers 

give you versatility in a simple to install, 24/7 

programmable package. These timers allow you to 

customize your timer schedule with automatic dusk/

dawn, random, and Daylight Saving Time (DST) 

programming options for up to 40 ON/OFF events. 

The ST01 Series and EI600 Series are incandescent/

fluorescent/CFL/LED compatible. In addition, these 

timers can handle any load type and require no 

neutral wire connection, making them ideal for any 

application, regardless of complexity.

TIMER INTERFACE

Display

Mode button

On/Off button

– button (Decrease)

+ button (Increase)

Reset button

Access door to 

battery tray

PRE-INSTALLATION

Before mounting the timer in the wall, install the 

supplied battery. 

1.  Gently pry open the access door, located below 

ON/OFF, and remove the battery tray from the 

timer. 

2.  Place the supplied CR2 battery into the battery 

tray, matching the battery 

+

 and 

 markings to 

the 

+

 and 

 markings on the tray, then place the 

battery tray back in the timer.

3.  The display initializes, then flashes 12:00 am in 

manual mode.

4.  Press ON/OFF. The timer “clicks” to confirm it is 

ready for programming.

Note: 

If the display doesn’t flash 12:00 am, check/replace 
the battery before proceeding.

NOTES

Read these notes before continuing with the timer 

installation and programming process.
•  The timer is battery-powered and does not need 

AC power for initial setup and programming. For 

new installations, it is recommended that you setup 

and program your timer before installing it.

•  The battery controls the ON/OFF function (“click-

ing” sound) and maintains the time and date. The 

screen flashes BATT when the battery strength is 

low. When replacing the battery, disconnect AC 

power. You will have a few minutes to insert new 

batteries before the date and time settings are lost. 

All other settings will remain in memory, without 

battery or AC power.

•  Each ON or OFF setting is an event. Each event 

must be programmed separately. 

•  The MODE menu includes SETUP, PGM (program), 

AUTO (automatic), RAND (random), and MAN 

(manual). AUTO and RAND modes do not appear 

on the menu options until the time of day is set and 

at least one ON or OFF event is programmed. 

•  All menus loop (repeat options when you get to the 

end of the menu). When in a specific Mode, press 

ON/OFF to loop within that Mode.

•  When using the 

+

 or 

 buttons to change a flashing 

setting, hold the button to make the numbers scroll 

faster. 

•  When advancing to the next setting, the timer au-

tomatically saves the data from the previous screen 

whether you changed a setting or not. All settings 

save automatically after five minutes.

PROGRAMMING

Follow these steps for initial setup and programming 

of the ST01 Series and EI600 Series timers.

Clear All Existing Settings

When first setting the timer, it is recommended that 

any existing settings be cleared.

1.  Press and hold ON/OFF button. 
2.  Using a paper clip or pen, press and release 

the RESET button. The timer displays INIT after 

approximately five seconds.

3.  Release the ON/OFF button. All previous settings 

are removed.

Initial Setup

1.  Press MODE until SETUP  

appears on the display.

2.  Press ON/OFF to advance to 

the next menu item (HOUR).

3.  Press + or - to adjust the 

flashing menu item (HOUR).

4.  Press ON/OFF to advance to 

the next menu item (MINUTES).

5.  Repeat steps 3 & 4 to set the 

MINUTES, YEAR, MONTH, 

and DATE. 

Note: 

After setting the DATE, the current day of the week 
flashes. Verify the DAY. If wrong, press + or - to review 
and adjust the YEAR, MONTH, and DAY. Press ON/
OFF to confirm.

6.  The DST selections (AUTO  

or MAN) flash on the display.
•  Press + to change the 

selection. 

 

Select AUTO if your 

location observes DST.

 

Select MAN to disable 

automatic DST 

adjustment.

•  Press ON/OFF to confirm and advance to 

ZONE selection.

Note: 

The remaining settings for initial setup (ZONE, DAWN, 
and DUSK settings) are only used for regulating 
Astronomic events. There is no need to adjust these 
settings if you are not scheduling an Astronomic 
event. 

7.  The ZONE selections* (CENT, SOU, or NRTH) 

flash on the display. 
•  Press + to change the 

selection to match 

your location on the 

map.

•  Press ON/OFF to 

confirm and advance 

to DAWN/DUSK selection.

Note: 

Astronomic adjustment on this product is designed 
for the continental United States. Astronomic 
schedules are not recommended for locations 
substantially beyond the continental US borders, 
including Alaska. For southern Canada, select “NRTH” 
zone. For northern Mexico, select “SOU” zone. Please 
visit 

www.intermatic.com

 for other timer models 

offering expanded Astronomic geographic coverage.

NORTH

CENTRAL

SOUTH

Reviews: