RC2000 SERIES
REMOTE CONTROLS
INSTALLATION
OPERATION &
SERVICE MANUAL
AIR OPERATED CONTROLS FOR POOL - SPA COMBINATIONS
Suitable for Pool Equipment Control and for Direct Connection of Underwater Lights
Model: RC2163E Control Center / Model: RC2163BE Control Panel
ONE BUTTON CONTROL FOR FILTER PUMP, HEATER AND VALVES
ELECTRICAL RATING: 20 Amp. Resistive - 120V or 240V; 1.5 HP - 120V, 3 HP - 240V, DPST.
Low Voltage: 24V - 40VA Maximum
Many of today’s pools and spas utilize the advantages of a single
electrical control panel, containing all the necessary components
for the safe, cost effective and automatic operation of a pool or spa.
Model RC2163E is designed to operate the shared equipment, like
the pump, filter and the heater of a Pool/Spa combination safely
from the spa side with only one air button.
The 24 hour timer turns ON the filter pump and automatically filters
and, if so set, heats the pool water on a daily schedule. In addition,
by the push of the air button at the spa side, the Control turns ON
the pump, the heater and rotates the valves thus allowing the water
to circulate in the spa. The Control also features a selector switch
for the heater. The switch has three positions and it can be set to
heat the water either in the spa only or both in the spa and in the
pool to two different pre-selected temperatures.
The Control also has provisions for connecting a freeze or heater
protection thermostat to its filter pump control logic board.
Model RC2163BE is the same as the one described above, except
it is built into an 8 circuit 100 AMP. sub-panel.
The Control coordinates the operation of the various pool/spa
equipment according to the following table:
Sequence 1
Sequence 2
EQUIPMENT
POOL MODE
SPA MODE
Filter Pump
Timer Controlled
ON - Continuously
Heater
If selected, Water Temperature
Water Temperature
is as Set by Pool Thermostat
is as Set by Spa Thermostat
Valves
Set to Pool Circulation
Set to Spa Circulation
1
DANGER! TO AVOID RISK OF INJURY:
...do not permit children to operate the Control Unit or use the Pool/Spa unless they are closely supervised at all times.
...test GROUND FAULT protection regularly. If it fails to reset, DO NOT USE THE POOL or SPA!
Contact a qualified service technician immediately.
...always disconnect electricity before servicing this control or the equipment connected to it.
READ, FOLLOW & SAVE THIS INSTRUCTION MANUAL
GENERAL INFORMATION
RC2163BE
RC2163E