background image

MODEL RC2123PT

This Air Switch is designed to control safely, 

without  electricity  at  the  spa  side,  the  filter 

pump,  120V  or  240V,  single  or  two  speed. 

Each time pressure is applied to the remote 

air  button,  the  connected  equipment  will 

operate  in  the  sequence  shown  below.  In 

addition,  the  timer  will  automatically  turn 

the pump ON/OFF (low speed if two speed 

pump) for daily filtration.
 

EQUIPMENT 

SEQUENCE

 

 

 

 

PUMP, SINGLE SPEED 

Timer 

ON

   

ON/OFF

  PUMP, TWO SPEED 

Timer

   

ON/OFF 

ON

   

Low 

High

   

Speed 

Speed

INSTALLATION

OPERATION & 

SERVICE MANUAL

ONE CIRCUIT AIR SWITCH WITH TIMER 

Model: RC2123PT - Plastic Outdoor (Type 3R) Enclosure

SUITABLE FOR POOL/SPA EQUIPMENT CONTROL

SWITCH: Single Pole Double Throw (SPDT)

RATINGS: 20 A Resistive - 120V or 240V; 1 HP - 120V, 2 HP - 240V, 60 HZ.

GENERAL INFORMATION

1

RC2000 SERIES

REMOTE CONTROLS

                             DANGER! To Reduce the Risk of Injury:

...do not permit small children to operate the control or use the Pool/Spa unless they are closely supervised at all times.

...test GROUND FAULT protection regularly. If it fails to reset, DO NOT USE THE POOL or SPA! Contact a service technician.

...always disconnect electricity before servicing this Control or the equipment connected to it. THIS CONTROL IS NOT TO BE USED 

AS A POWER DISCONNECT. 

                                IMPORTANT SAFETY INSTRUCTIONS

When installing and operating this Product and other associated equipment, basic safety precautions should always be followed, 

1.  Read and follow all instructions.

2.  This Control must be installed by a qualified person, according to National and Local Electrical Codes.

3.  Install this control not less than 5 feet (3 meters in Canada) from inside edge of pool 1 foot (30 cm) or more above ground. 

  USE COPPER CONDUCTORS ONLY, rated 75˚C minimum. 

4.  Do not exceed the maximum ratings of individual components, wiring devices, and current carrying capacity of conductors.

5.  For Control grounding and bonding, refer to Article 680 of the National Electrical Code or Article 68 of the Canadian Electrical Code.

6.  The Control should not operate any equipment which would cause bodily injury or property damage should it be activated 

  unexpectedly.

 

                                         