Intermatic PE25300 Installation, Operation & Service Manual Download Page 3

ACCESSORIES

TROUBLESHOOTING

3

SYMPTOM

CAUSE(S)

CORRECTIVE ACTION    

1. Display will not come “ON”

1a. Jumper on back of clock is missing

Set Jumper to proper location. See

when unit is powered up?

or set incorrectly.

Pg.7 of instruction manual. 

1b. Fuse on back of clock blown open.

Replace fuse with 1/8 amps fuse.
See Pg. 7 of instruction manual.

1c. Power to clock not present.

Check connections to clock.
Check circuit breakers.

2. Freeze protection circuit not 

2a. Freeze Probe (P/N 178PA28A)

Install Intermatic freeze probe. See

working?

not installed or bad.

Pg. 7 of instruction manual.

2b. Clock programming not setup.

Setup freeze programming. See
Pg. 7 of instruction manual.

3. Unit does not turn “ON” or

3a. Internal ON/OFF Times have 

Setup ON/OFF programming. See

“OFF” at desired times?

not been defined.

Pg.’s 24-27 of instruction manual.

3b. ON or OFF time is in override mode.

Cycle through programming menu. 
See Pg.’s 24-27 of instruction 
manual.

3c. Clock is in Freeze protection

Review programming menu. See

Countdown Mode.

Pg.’s 29 & 33 of instruction manual.

4. Display continues to blink ON 

4a. Power to clock was interrupted long 

Set time of day on clock.See Pg. 23 

and OFF?

enough to loose time of day.

of instruction manual.

4b. Clock still in programming mode.

Press “ENTER KEY” or wait 1
minute for clock to time out.

5. Fireman switch not working?

5a. Fireman switch wires not hooked up

Connect fireman switch wires to

correctly from heater.

clock. See Pg. 7 of instruction
manual.

5b. Fireman switch programming not

Program fireman switch settings.

defined.

See Pg. 28 of instruction manual.

FLTR

PUMP

2

PUMP

1

HTR

SPA

JETS

AIR

CLNR

LITE 1

LITE 2

HIGH

LOW

AUX 1

AUX 2

AUX 3

W/FA

External Wired Remote Accessory
Part Number 133PE1484A
The New Intermatic Wired Remote Control allows
you to control your Digital Time Clock  from
a remote location. Included with your Wired 
Remote Control is a label arrangement 
allowing you to identify each button 
specific to your Pool or spa equipment
pad. Your new wired remote control 
comes standard with 100 foot of cable
and is designed to slip fit into any 
standard 1 1/2” conduit adapter. This 
remote works in conjunction with the 
Digital Time Clock and displays feedback information
on the present state of the pool or spa equipment pad.
For more information refer to instructions provided
with the accessory.

Freeze Probe Accessory
Part Number 178PA28A
The New Intermatic Freeze Probe allows

you to protect your pool or
spa equipment during an
unexpected freeze condition.
The freeze probe comes with
a 10 foot cable and  plugs into
the back of the new Digital
Time Clock. The Time Clock
can be programmed to turn on
each or all-individual loads at

any desired outside temperature.

Heater Protection (Fireman) Switch is

standard with each Digital Time Clock.
It comes standard with a Fireman Switch
connection for your pool or spa heater.
Simply connect the two wires from your
heater thermostat to the back of the digital
clock. The fireman switch is only 
associated with circuit one on the digital
clock, therefore the filter pump should be
connected to circuit one. Program the time
desired for the cool down period and your
new digital clock will take over.
For more details, refer to instruction 
manual.

Reviews: