![Intermatic PE25300 Installation, Operation & Service Manual Download Page 3](http://html1.mh-extra.com/html/intermatic/pe25300/pe25300_installation-operation-and-service-manual_2077447003.webp)
ACCESSORIES
TROUBLESHOOTING
3
SYMPTOM
CAUSE(S)
CORRECTIVE ACTION
1. Display will not come “ON”
1a. Jumper on back of clock is missing
Set Jumper to proper location. See
when unit is powered up?
or set incorrectly.
Pg.7 of instruction manual.
1b. Fuse on back of clock blown open.
Replace fuse with 1/8 amps fuse.
See Pg. 7 of instruction manual.
1c. Power to clock not present.
Check connections to clock.
Check circuit breakers.
2. Freeze protection circuit not
2a. Freeze Probe (P/N 178PA28A)
Install Intermatic freeze probe. See
working?
not installed or bad.
Pg. 7 of instruction manual.
2b. Clock programming not setup.
Setup freeze programming. See
Pg. 7 of instruction manual.
3. Unit does not turn “ON” or
3a. Internal ON/OFF Times have
Setup ON/OFF programming. See
“OFF” at desired times?
not been defined.
Pg.’s 24-27 of instruction manual.
3b. ON or OFF time is in override mode.
Cycle through programming menu.
See Pg.’s 24-27 of instruction
manual.
3c. Clock is in Freeze protection
Review programming menu. See
Countdown Mode.
Pg.’s 29 & 33 of instruction manual.
4. Display continues to blink ON
4a. Power to clock was interrupted long
Set time of day on clock.See Pg. 23
and OFF?
enough to loose time of day.
of instruction manual.
4b. Clock still in programming mode.
Press “ENTER KEY” or wait 1
minute for clock to time out.
5. Fireman switch not working?
5a. Fireman switch wires not hooked up
Connect fireman switch wires to
correctly from heater.
clock. See Pg. 7 of instruction
manual.
5b. Fireman switch programming not
Program fireman switch settings.
defined.
See Pg. 28 of instruction manual.
FLTR
PUMP
2
PUMP
1
HTR
SPA
JETS
AIR
CLNR
LITE 1
LITE 2
HIGH
LOW
AUX 1
AUX 2
AUX 3
W/FA
External Wired Remote Accessory
Part Number 133PE1484A
The New Intermatic Wired Remote Control allows
you to control your Digital Time Clock from
a remote location. Included with your Wired
Remote Control is a label arrangement
allowing you to identify each button
specific to your Pool or spa equipment
pad. Your new wired remote control
comes standard with 100 foot of cable
and is designed to slip fit into any
standard 1 1/2” conduit adapter. This
remote works in conjunction with the
Digital Time Clock and displays feedback information
on the present state of the pool or spa equipment pad.
For more information refer to instructions provided
with the accessory.
Freeze Probe Accessory
Part Number 178PA28A
The New Intermatic Freeze Probe allows
you to protect your pool or
spa equipment during an
unexpected freeze condition.
The freeze probe comes with
a 10 foot cable and plugs into
the back of the new Digital
Time Clock. The Time Clock
can be programmed to turn on
each or all-individual loads at
any desired outside temperature.
Heater Protection (Fireman) Switch is
standard with each Digital Time Clock.
It comes standard with a Fireman Switch
connection for your pool or spa heater.
Simply connect the two wires from your
heater thermostat to the back of the digital
clock. The fireman switch is only
associated with circuit one on the digital
clock, therefore the filter pump should be
connected to circuit one. Program the time
desired for the cool down period and your
new digital clock will take over.
For more details, refer to instruction
manual.