Installation

1. Read the operating instructions carefully.
2.  Check  the  input  and  output  ratings  marked  on  the 

unit  to  make  sure  this  product  is  suitable  for  your 
application.

3. Disconnect power supply prior to installation to pre-

vent electrical shock.

4. Damage to the contacts caused by short circuiting 

will void warranty.

5.  Wire  in  accordance  with  National  and  local  electri-

cal code requirements.

BE SURE ALL CONNECTIONS ARE SECURE. 
DOUBLE CHECK ALL TWIST-ON WIRE CON-
NECTORS.

6. Mount timer into wall box using supplied screws.
7. If timer does not operate, check that the timer’s black 

wire is connected to hot line and not the load. If nec-
essary, reverse connections to red and black wires.

Manual Operation

The  slide  switch  provides  manual  operation  of  the 
load, overriding the timer. If set to the      position, the 
load will be continuously off, and if set to       , it will be 
continuously  on.  For  automatic  timed  on’s  and  off’s, 
the switch must be in the       position.

Programming

The  timer  dial  contains  72  “trippers”  which,  when  set 
at  the  inner  perimeter  of  the  dial,  will  turn  the  switch 
“ON” at the time adjacent to the tripper. The switch will 
return to the “OFF” position when the timer progresses 
past the inward trippers.
The 72 trippers allow multiple on/off sequences with a 
minimum on or off time of 20 min. To program, set all 
trippers inward for the duration of the on event.
For  example,  to  turn  lights  on  at  5:00pm  and  off  at 
11:00pm, leave inward the 18 trippers between 5 and 
11  on  the  “pm”  side  of  the  dial.  Make  sure  manual 
switch is in the      position.

NOTE: 

For  any  times  where  “OFF”  programming 

is  desired,  the  trippers  must  be  moved  to  the  outer 
perimeter of the dial.

Setting The Time

Rotate  the  dial 

clockwise

  until  the  correct  time  and 

“am” or “pm” is opposite the arrow on the plate.
CAUTION:  Do  not  turn  dial  counter-clockwise,  as  the 
timer will be damaged.

158--00534

Wiring Diagrams

ONE YEAR WARRANTY

If  this  unit  fails  due  to  a  defect  in  material  or  workman-
ship within one year after purchase, Intermatic will repair 
or replace the unit free of charge. This warranty does not 
apply  to  damage  due  to  accidents,  abuse,  mishandling 
nor  to  units  not  used  in  accordance  with  directions.  This 
warranty gives you specific legal rights, and you may also 
have other rights which vary from state to state.

Distributed by:

HOT (BLACK)

(RED)

3-Way Switch

(BLUE)

LOAD 

NEUTRAL (WHITE)

HOT (BLACK)

LOAD (RED)

LOAD 

NEUTRAL (WHITE)

Standard Installation

3-Way Installation

INTERMATIC INCORPORATED

Spring Grove, IL 60081-9698

www.intermatic.com