background image

• 

All Ratings 125 VAC, 60 Hz

• 

15A  / 1875W Resistive / Heater

• 

15A, General Purpose

• 

8A  / 1000W Tungsten

• 

8A  /  STD Ballast

• 

500 VA Electronic Ballast

• 

1/4 HP Motor

1. 

   Disconnect power to fixture.

2. 

    Remove wall plate and disconnect existing light switch. 

3. 

    Be sure to have neutral, hot, and switch leg in box. If all wires 

are not present, additional wiring will be necessary before 
installation can be completed. (See Fig. 1)

4. 

    Connect red timer wire to fixture wire and secure with wire 

connector. (See Fig. 2)

5. 

    Connect black timer wire to the hot wire in junction box and 

secure with wire connector. 

6. 

    Connect white timer wire to white wires in junction box and 

secure with wire connector.

7. 

   Connect green timer wire to existing ground.

8. 

    Check that all wire connections are secure. 

9. 

   Place all wires inside junction box.

10. 

 Fit timer into junction box and install using two (2) mounting  
screws (furnished).

11. 

Reconnect the electrical power.

Setting the Clock

1. 

   Press and hold 

CLK

 and press 

DAY

 to scroll to current day.

2. 

   Press and hold 

CLK

 and press 

HOUR

 to scroll to current hour.

3. 

   Press and hold 

CLK

 and press 

MIN

 to scroll to current minute.

Setting Programs

1. 

   Press 

PROG.

 The 1 ON (Event 1 ON) screen appears.

2. 

   Press 

DAY

 to scroll to the day(s) for the event to turn ON.

3. 

   Press 

HOUR

 and 

MIN

 to set ON time for the event.

4. 

   Press 

PROG.

 The 1 OFF (Event 1 OFF) screen appears.

5. 

   Repeat Steps 2-3 to set the OFF time for Event 1.

6. 

    Repeat procedure to set additional ON/OFF events.

 

NOTE:

 Do not set events within 30 minutes or less of each other if using  the Random Mode. 

The Random Mode interval is ± 15 minutes from the programmed times, and programs set too 
close together may overlap one another.

7. 

   When all events are set, press 

CLK

 to return to time screen.

Clearing (Deleting) an Event

1. 

   Press 

PROG

 to scroll to the setting you want to clear.

2. 

   Press and hold 

MODE

 and press 

PROG

 to clear the setting.

3. 

   Press 

CLK

 to return to the time of day screen.

Operating the Time Switch

     Press 

MODE

 to set Automatic, Random or Manual mode. 

NOTE:

 For the time switch to run programmed events, it must be set to AUTO or  RDM 

mode.  

NOTE:

 After setting events, the timer may turn on the load if you press the MODE button.

• 

AUTO

 (Automatic) mode runs all events automatically, according to the schedule you have 

set. 

• 

RDM

 (Random) mode is a security feature in which ON and OFF times randomly differ 

± 15 minutes from the programmed times, creating a more lived-in look. 

• 

MANUAL

 mode turns ON and OFF only when the user presses the ON or OFF button. 

Overriding Timer Settings

The 

ON

 or 

OFF

 buttons override the current programmed events.

To override the current program (either ON or OFF), press the 

ON

 or 

OFF

 button. 

NOTE:

 If the timer is not in “Manual” mode, it will obey the next programmed event. 

This allows the user to manually turn a light on and allow the program to shut the 
light back off at a preset time.

Resetting the Timer

In case of an operational failure of the timer, press the 

RESET

 button to clear all 

settings and restart.

LIMITED  ONE-YEAR WARRANTY

If within the warranty period specified, this product fails due to a defect in material or workmanship, 

Intermatic Incorporated will repair or replace it, at its sole option, free of charge. This warranty is 

extended to the original household purchaser only and is not transferable. This warranty does not apply 

to: (a) damage to units caused by accident, dropping or abuse in handling, acts of God or any negligent 

use; (b) units which have been subject to unauthorized repair, opened, taken apart or otherwise modi-

fied; (c) units not used in accordance with instructions; (d) damages exceeding the cost of the product; 

(e) sealed lamps and/or lamp bulbs, LED’s and batteries; (f) the finish on any portion of the product, 

such as surface and/or weathering, as this is considered normal wear and tear; (g) transit damage, 

initial installation costs, removal costs, or reinstallation costs.

INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAM-

AGES. SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CON-

SEQUENTIAL DAMAGES, SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU. 

THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES. ALL IMPLIED 

WARRANTIES, INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FIT-

NESS FOR A PARTICULAR PURPOSE, ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN 

THIS LIMITED WARRANTY, AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD 

STATED ABOVE. SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED 

WARRANTY, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU.

This warranty service is available by either (a) returning the product to the dealer from whom the unit 

was purchased or (b) completing a warranty claim online at www.intermatic.com.
This warranty is made by: Intermatic Incorporated, Customer Service 7777 Winn Rd., Spring Grove, 

Illinois 60081-9698.  For warranty service go to:  http://www.Intermatic.com or call 815-675-7000.

Ratings:

Installation:

Installation and User Instructions

MODEL IW505K

• 

Turn off power at circuit breaker and test that power is off before wiring.

• 

Follow local electrical codes during installation.

• 

Connect to copper conductors only.

• 

No user-serviceable parts.

• 

The internal battery requires up to 30 minutes to charge. If the battery is not charged and power 

is lost, schedule information may have to be re-configured.

 Risk of Fire or Electric Shock 

 WARNING

NOTICE

Figure 1

Figure 2

WIRE FROM 

FIXTURE

HOT 

(BLK OR RED)

NEUTRAL

WIRE FROM FIXTURE

In-Wall Timer

• 

Toutes caractéristiques sous 125 V c.a., 60 Hz.

• 

15 A / 1875 W résistif / radiateur

• 

15 A usage général

• 

8 A / 1000 W tungstène

• 

8A / ballast STD

• 

500 VA ballast électronique

• 

Moteur 1/4 HP

1. 

   Couper l’alimentation électrique du luminaire.

2. 

    Déposer la plaque murale et débrancher l’interrupteur 

d’éclairage existant. 

3. 

    Vérifier qu’il y a bien les fils de phase, de neutre et 

d’interrupteur dans la boîte. S’il n’y a pas tous les fils, il peut 
être nécessaire de tirer des câbles supplémentaires avant de 
pouvoir effectuer l’installation (voir Fig. 1).

4. 

    Raccorder le fil rouge de la minuterie au fil du luminaire à 

l’aide d’une marrette (voir Fig. 2).

5. 

    Raccorder le fil noir de la minuterie au fil de phase dans la 

boîte de dérivation à l’aide d’une marrette. 

6. 

    Raccorder le fil blanc de la minuterie aux fils blancs dans la boîte de 

dérivation à l’aide d’une marrette.

7. 

   Raccorder le fil vert de la minuterie à une terre existante.

8. 

    Vérifier que tous les fils sont solidement raccordés. 

9. 

   Placer tous les fils à l’intérieur de la boîte de dérivation.

10. 

 Placer la minuterie dans la boîte de dérivation et l’attacher à l’aide 
de deux (2) vis de fixation fournies.

11. 

Rétablir l’alimentation électrique.

Régler l’horloge

1. 

   Tenir la touche 

CLK

 enfoncée et appuyer sur 

DAY

 pour avancer jusqu’au jour courant.

2. 

   Tenir la touche 

CLK

 enfoncée et appuyer sur 

HOUR

 pour avancer jusqu’à l’heure courante.

3. 

   Tenir la touche 

CLK

 enfoncée et appuyer sur 

MIN

 pour avancer jusqu’à la minute courante.

Configurer les programmes

1. 

   Appuyer  sur 

PROG.

 L’écran 1 ON (événement 1 Marche) s’affiche.

2. 

   Appuyer  sur 

DAY

 pour avancer jusqu’au(x) jour(s) où l’événement ON doit avoir lieu.

3. 

   Appuyer  sur 

HOUR

 et 

MIN

 pour régler l’heure de l’événement ON.

4. 

   Appuyer  sur 

PROG.

 L’écran 1 OFF (événement 1 Arrêt) s’affiche.

5. 

   Répéter les étapes 2 et 3 pour régler l’heure d’arrêt (OFF) de l’évènement 1.

6. 

    Répéter cette procédure pour définir des événements ON/OFF supplémentaires.

 

REMARQUE :

 Ne pas configurer des événements à 30 minutes ou moins les uns des autres si le 

mode aléatoire (RDM) est utilisé. L’intervalle du mode aléatoire est de ± 15 minutes par rapport aux 
heures programmées et des programmes configurés trop près l’un de l’autre peuvent se recouvrir.

7. 

   Une fois tous les événements configurés, appuyer sur 

CLK

 pour retourner à l’écran de l’heure.

Effacer (supprimer) un événement

1. 

   Appuyer  sur 

PROG

 pour avancer jusqu’au paramètre à supprimer.

2. 

   Tenir la touche 

MODE

 enfoncée et appuyer sur 

PROG

 pour supprimer le paramètre.

3. 

   Appuyer  sur 

CLK

 pour retourner à l’écran de l’heure de la journée.

Utiliser la minuterie

     Appuyer sur 

MODE

 pour mettre en mode automatique, aléatoire ou manuel. 

REMARQUE :

 

Pour que la minuterie exécute les évènements programmés, elle doit être en 

mode 

AUTO

 (automatique) ou 

RDM

 (aléatoire).  

REMARQUE :

 Une fois les évènements configurés, l’appareil contrôlé peut être mis en 

marche en appuyant sur le bouton 

MODE

 de la minuterie.

• 

Le mode 

AUTO

 (automatique) exécute tous les évènements automatiquement suivant le 

calendrier fixé. 

• 

Le mode 

RDM 

(aléatoire) offre une fonctionnalité de sécurité par laquelle les heures de 

marche et d’arrêt s’écartent de façon aléatoire de ± 15 minutes des heures programmées, 
pour créer un effet plus « habité ». 

• 

Le mode 

MANUAL

 (manuel) commande la marche et l’arrêt uniquement lorsque 

l’utilisateur appuie sur les touches 

ON

 (marche) et 

OFF

 (arrêt). 

Caractéristiques :

Pose :

Instructions d’installation et mode d’emploi

MODÈLE IW505K

• 

Couper le courant au disjoncteur et vérifier que le circuit est hors tension avant de câbler.

• 

Effectuer l’installation conformément au code de l’électricité en vigueur.

• 

Raccorder exclusivement à des conducteurs en cuivre.

• 

Aucune pièce réparable par l’utilisateur.

• 

La batterie interne nécessite jusqu’à 30 minutes pour se recharger. En cas de coupure de courant 

alors que la batterie est déchargée, il peut être nécessaire de reprogrammer le calendrier.

AVIS

Figure 1

Figure 2

Minuterie murale encastrée

FIL DU 

LUMINAIRE

PHASE 

(NOIR OU 

ROUGE)

NEUTRE

FIL DU LUMINAIRE

ROUGE

VERT

BLANC

NOIR

TERRE

AVERTISSEMENT

Risque d’incendie ou de choc électrique

Reviews: