background image

INSTALLATION

OPERATION &

SERVICE MANUAL

Model: PF1103 FREEZE PROTECTION CONTROL

 

IN RAINPROOF (TYPE 3R) ENCLOSURE

 

Model: PF1103M FREEZE PROTECTION CONTROL MECHANISM

SUITABLE FOR POOL/SPA EQUIPMENT CONTROL

INPUT VOLTAGE: 120 VOLT - 60 HZ OR 240 VOLT - 60 HZ.

ELECTRICAL RATING: 3 HP - 240 VOLT AC.

DANGER! To Reduce the Risk of Injury:

...do not permit children to operate the Control Unit or use the Pool/Spa unless they are closely supervised at all times.
...test GROUND FAULT protection regularly. If it fails to reset, DO NOT USE THE POOL or SPA! Contact a qualified 
service technician.
...always disconnect electricity before servicing this control or the equipment(s) connected to it. THIS CONTROL IS NOT 
TO BE USED AS A POWER DISCONNECT.

 READ, FOLLOW & SAVE THIS INSTRUCTION MANUAL

GENERAL INFORMATION

Model  PF1103

  Freeze  Protection  Control  is  self-contained  in  an  indoor-outdoor,  beige,  rainproof

enclosure and designed to be connected to a timing or switching device. Together, they control as well
as protect the Pool/Spa equipment and
plumbing against freeze damage. The Control,
if wired according to instructions, turns ON
the Filter Pump when the air 
temperature (where this Control is
located) drops below the temperature
set by the thermostat dial (between 
32˚F and 45˚F). Nevertheless, the
Control is not intended to be a 
substitute for the insulation, coverings or
maintenance.

Model PF1103M

 is a mechanism only, 

functions just like Model PF1103 and 
fits (snaps into) any Intermatic Pool 
Panel, Models T10000R, T30000R or 
T40000R Series. Both models are 
designed to operate either on 120 Volt
or 240 Volt, 60 cycle. When used on 
240 Volt however, the neutral wire must be 
installed and it is not recommended for 
controlling 240 Volt GFCI protected 
equipment. For such application, use 
Model PF1102 or PF1102M Freeze 
Protection Control.

FREEZE PROTECTION

FOR POOLS, SPAS

AND WATER FEATURES

By

158PF11834.indd   1

3/24/09   9:00:32 AM

http://waterheatertimer.org/Intermatic-freeze-controls.html#PF11

Reviews: