background image

Figure 1

Hinge

Trunion 

Mounting

Bracket

Screw

Trunion 

Bolt

Positioning

Screw

Figure 2 (Mount Fixture horizontal)

Lens 

Cover

Lamp  

Holder

Reflector

4 ft. Outdoor 

3-wire Cord

HID Flood Light - FL Series

INSTALLATION INSTRUCTIONS

Models: FL250HPS, FL400HPS, FL250MH, FL400MH

FL250HSPT, FL400HPST, FL250MHT & FL400MHT

FOR OUTDOOR USE ONLY

NOT FOR USE IN HAZARDOUS 

ATMOSPHERES

IMPORTANT: Read instruction sheet 

carefully before installing fixture. Retain 

instructions for future reference.

ELECTRICAL REQUIREMENTS

A  qualified  electrician  should  complete  all  required  wiring.  Models  FL250HPS,  FL400HPS,  FL250MH  &  FL400MH  will 
accept 120, 208, 240 or 277 Volts AC. Models FL250HSPT, FL400HPST, FL250MHT & FL400MHT will accept 120, 277 
or 347 Volts AC. Fixtures must be properly grounded for safety. A mounting suitable for outdoor use and rated for wet 
locations is required. Follow all applicable electrical codes and regulations.

Please see below for list of warnings.

 

 

WARNING 

  Electric shock hazard

Disconnect power at circuit breaker or fuse box before 
installing or servicing light. 

 

 

WARNING 

  Fire hazard

USE MIN 90°C SUPPLY CONDUCTORS. CONNECT TO 
SUPPLY IN EXTERNAL JUNCTION BOX ONLY. 
Lamp and housing become very hot during use. Ensure free 
air circulation around unit to dissipate heat. Avoid enclosed 
locations and locations where flammable debris (leaves, cut 
grass, etc.) might collect. Avoid locations where humans or 
animals might accidentally touch fixture.

 

 

WARNING 

  Fire hazard

USE MINIMUM 125°C SUPPLY CONDUCTORS IF CORD 
IS NOT USED.

 

 

WARNING 

  Explosion hazard

Never operate light without securing the lens door. When 
light is operating, the gas in the lamp inner arc tube is at 
high pressure. Never operate light if the fixture lens or outer 
glass envelope of the lamp is broken or missing.

 

 

WARNING 

  Explosion hazard

Wear safety glasses and gloves when handling lamp, High 
Pressure Sodium outer envelope is under vacuum and could 
implode. Metal Halide outer envelope is pressurized and 
could explode if broken.

 

 

WARNING 

  UV hazard 

(Metal Halide Lamps Only)

The type of lamp used in this fixture can cause serious 
skin burn and eye inflammation from short wave ultra 
violet radiation if outer envelope of the lamp is broken or 
punctured, and the arc tube continues to operate. Do not 
use where people will remain for more than a few minutes. 
Certain types of lamps that will automatically extinguish 
when the outer envelope is broken or punctured are 
commercially available.

 

 

WARNING

Lamp Types: 

High Pressure Sodium 250 Watt  & 400 Watt
High Pressure Sodium 250 Watt  & 400 Watt with Tri-Tap
Metal Halide 250 Watt & 400 Watt
Metal Halide 250 Watt & 400 Watt with Tri-Tap

MOUNTING & WIRING

Remove Trunion Bolts and positioning screw to free Trunion 
Mounting Bracket.
Install Trunion Mounting Bracket to desired location. Fixture 
should  be  horizontal  when  attached  to  mounting  bracket. 
(See Figure 2)
Loosen  (2)  screws  and  open  Lens  cover.  Remove  lens 
cover  and  set  aside  to  prevent  damage  during  installation 
of fixture.
Loosen  (4)  screws  and  remove  reflector/lampholder 
assembly.
Identify supply voltage.

1.

2.

3.

4.

5.

Reviews: