background image

Latch location

Tilt top forward

Installation

Follow these instructions to install the time switch. 
1.  Open the time switch enclosure door.
2.  Remove and retain the screw that secures the plastic insulator.
3.  Lift the left side of the plastic insulator and pivot away to expose the terminal strip. 
4.  Press the latch at the top of the enclosure and pull out the mechanism from the 

enclosure.

5.  Choose and remove the selected knockout(s) from the enclosure.

NOTE:

 There are five 1/2 inch to 3/4 inch combination knockouts available. There are 

two on the bottom of the enclosure, one on each side, and one on the rear. If a 3/4 
inch knockout is needed, remove the 1/2 inch knockout first, then the 3/4 knockout.

6.  Place the enclosure in the desired location providing space for the enclosure door to 

swing open fully.

7.  Securely mount enclosure using provided mounting holes.
8.  Use appropriately rated fittings for the installation.
9.  Snap the mechanism back into the enclosure.
10.  Strip 1/2 inch off the supply and load wires. Use AWG #14-#8 copper conductors 

rated at least 105ºC.

11.  Connect the wires to the proper terminals on the time switch and tighten the screws 

firmly (See wiring diagrams).

12.  Connect ground wire to grounding terminal at the bottom of metal enclosures.
13.  Return the insulator to its original position and replace the screw.
14.  Close enclosure door.
15.  Apply power to the time switch.

Wiring Diagram

1/2 inch

LOAD1

L1
L2/N

N

L

(120/277 VAC LOAD)

CIRCUIT 1

TIMER 

POWER

COM1

NO-1

AC  IN

OUTPUT CONFIGURATION: IND

Summary of Contents for ET2705C

Page 1: ...equipment generates uses and radiates radio frequency energy and if not installed and used in accordance with instructions may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference that requires the user to correct at his or her own expense MODELS ET2705C ET2705CR ET2705CP Shown in indoor outdoor lockable metal ...

Page 2: ... inch knockout first then the 3 4 knockout 6 Place the enclosure in the desired location providing space for the enclosure door to swing open fully 7 Securely mount enclosure using provided mounting holes 8 Use appropriately rated fittings for the installation 9 Snap the mechanism back into the enclosure 10 Strip 1 2 inch off the supply and load wires Use AWG 14 8 copper conductors rated at least ...

Page 3: ... select the current time NOTE Seconds can be set to 00 by pressing ENTER NEXT 3 Press MODE to save the time and move to the Enable Daylight Saving Time mode selection NOTE If the time switch programming data is to be read from a USB memory stick refer to the Read Time Switch Program Data section in these instructions Enable Disable Daylight Saving Time and Setting Daylight Saving Time Rule Configu...

Page 4: ... this event or press to keep this event for the selected day 6 Press DAY to move to the next day of the week repeat step 6 7 When all the days are set press ENTER NEXT to save 8 The Event Number increments and the SET FIXED ON OFF EVENTS and OFF icons are displayed Press ENTER NEXT if this fixed off event is not needed go to step 15 9 If an event is not set the time display will show 10 Press DAY ...

Page 5: ...played on the right side of the display 16 Press the or buttons to set the time for this holiday event to end 17 Press ENTER NEXT and the SET DATE and ON icons appear on the display The next holiday number is displayed on the right side of the display If Then Another holiday period needs to be set Return to step 2 All the events are set Press MODE to save and exit The procedure is complete Example...

Page 6: ...s ENTER and insUSb is displayed 3 Insert a USB memory stick into the USB port on the front face of the time switch 4 SCHEdL 01 is displayed Press or to increment decrement the schedule number on the display 01 99 5 When the desired number is displayed press ENTER and this will write the data file to the USB memory stick The file name will be SCHEDLxx TXT where xx is the schedule number selected in...

Page 7: ...ort on the time switch is not functioning Specifications Input Voltage 120 277 VAC 60 Hz Power Consumption 3 W MAX Switch Configuration SPST x 1 See wiring diagrams in this manual Switch Ratings Rating Load Type Voltage Frequency 30 A Resistive 120 240 VAC 60 Hz 20 A Resistive 28 VDC 30 A Inductive 120 240 VAC 60 Hz 20 A Magnetic Ballast 120 277 VAC 60 Hz 10 A Electronic Ballast 120 277 VAC 60 Hz ...

Page 8: ... BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES ALL IMPLIED WARRANTIES INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY MO...

Reviews: